11. Safety devices

Type of
protection
Circuit
Current fuse
protection
(Main PCB)
Fan motor
Thermal protection program
protection
Thermal protection program
(Discharge temp.)
Compressor
protection
Thermal protection program
(Compressor temp.)
Protection form
Activate
Reset
Activate
Reset
Activate
Reset
- 57 -
Model
AOEH30KMTB
250 V, 30 A
250 V, 3.15 A
250 V, 10 A × 2
122 ±9 °C
Fan motor stop
107—126 °C
Fan motor restart
110 °C
Compressor stop
After 7 minutes
Compressor restart
108 °C
Compressor stop
80 °C or less
Compressor restart
AOEH36KMTB