10.8.2. Replacing resistor -R462_1, -R462_2

Service MTTR 0 - 2 h
Figure 10–46 Resistor -R462_1, -R462_2
1. Shut down the PCS6000 according to the "PCS6000 Lockout/tagout procedure",
3BHS600000 E22.
2. Disconnect all electrical cables.
3. Unbolt the Torx screws for the resistor, which have to be replaced.
4. Replace the faulty resistor.
5. Restart the PCS6000 according to section 5.4, Start-up after maintenance or
troubleshooting, page 70.