AKT 905
GB
LIGHTING THE BURNERS
•
To ignite one of the burners, turn the relative knob anti-clockwise to the maximum flame setting
•
Press the knob against the control panel to ignite the burner.
•
After the burner has ignited, keep the knob pressed for about 5 seconds to allow the thermocouple to warm up.
This burner safety device shuts off the gas supply to the burner if the flame goes out accidentally (because of sudden
draught, an interruption in the gas delivery, boiling over of liquids, etc.).
•
The device must not be pressed for more than 15 sec. If, after that time has elapsed, the burner does not
remain lit, wait at least one minute before trying to light it again.
-
The burner might go out when the knob is released. This means that the thermocouple has not warmed up enough.
In this case, repeat the operations described above.
PRATICAL ADVICE FOR USING THE BURNERS
For better burner performance, please stick to the following
rules:
-
Use pots and pans that fit the burners (see table on the
right).
-
Only use flat-bottomed pots and pans.
-
Use the correct amount of water for cooking foods and
keep the pot covered.
-
In the case of pans with convex bottoms (WOK), use
the support grille provided, which should be positioned
only on the 4 ring burner.
5019 319 01337
PRODUCT DESCRIPTION SHEET
1.
Removable panstand grids
2.
Semi-rapid burner
3.
Auxiliary burner
Semi-rapid burner
4.
Rapid burner
5.
4 ring burner
6.
Auxiliary burner control knob
7.
Rapid burner control knob
8.
4 ring burner control knob
9.
10.
Semi-rapid burner control knob
11.
Semi-rapid burner control knob
SYMBOLS
Tap closed
Maximum flame
Minimum flame
.
Burner
Pot Ø
4 ring
from 24 to 26 cm
Rapid
from 24 to 26 cm
semi-rapid
from 16 to 22 cm
auxiliary
from 8 to 14 cm
To get full satisfaction from the hob, please read these instructions carefully and keep them for future consultation.
DIMENSIONS AND DISTANCES TO BE MAINTAINED (mm)
INJECTOR TABLE
Type of gas used
Type of burner
Injector
marking
4 ring
139
NATURAL GAS
Rapid
128
Semi-rapid
95
(Methane)
G20
Auxiliary
78
4 ring
95
LIQUID
Rapid
87
PETROLEUM GAS
Semi-rapid
67
(Butane)
G30
Auxiliary
50
LIQUID
4 ring
95
Rapid
87
PETROLEUM GAS
Semi-rapid
67
(Propane)
G31
Auxiliary
50
Type of gas
Configuration
Rated thermal
used
model
flow rate kW
G20 20 mbar
5 burners
G30 28-30 mbar
5 burners
G31 37 mbar
5 burners
ELECTRIC SUPPLY: 230 V - 50 Hz
Destinations
PT
CATEGORY II2H3+
Rated thermal
Rated
Reduced heat
Gas pressure (mbar)
flow rate kW
consumption
capacity kW
min.
3.50
333 l/h
1.50
3.00
286 l/h
0.60
17
1.65
157 l/h
0.35
1.00
95 l/h
0.30
3.50
254 g/h
1.50
3.00
218 g/h
0.60
20
1.65
120 g/h
0.35
1.00
73 g/h
0.30
3.50
250 g/h
1.50
3.00
214 g/h
0.60
25
1.65
118 g/h
0.35
1.00
71 g/h
0.30
Total rated
Air necessary (m
consumption
combustion of 1 m
10.8
1028 l/h
10.8
785 g/h
10.8
771 g/h
ES
GB
IT
rat.
max.
20
25
28-30
35
37
45
3
) for the
3
of gas
9.52
30.94
23.80