IMPORTANT SAFETY INSTRUCTIONS

A qualified electrician must perform a ground continuity
check on the wall receptacle before beginning the
installation to ensure that the outlet box is properly
grounded. If not properly grounded, or if the wall
receptacle does not meet electrical requirements noted
(under ELECTRICAL REQUIREMENTS), a qualified electrician
should be employed to correct any deficiencies.
WARNING:
Can cause injury or death: THIS APPLIANCE MUST BE
PROPERLY GROUNDED to avoid severe or fatal shock.
120 V Models
Ensure proper
ground exists
before use.
Installation Instructions
WARNING:
Risk of Electric Shock.
Can cause injury or death:
Remove house fuse or
open circuit breaker before
beginning installation to avoid
severe or fatal shock injury.
Risk of Electric Shock.
The power cord of this
appliance is equipped with
a three-prong (grounding)
plug which mates with
a standard three-prong
(grounding) wall receptacle
to minimize the possibility
of electric shock hazard
from this appliance.
Where a standard two-prong wall receptacle is
encountered, it must be replaced with a properly
grounded three-prong wall receptacle, installed by a
qualified electrician.
WARNING:
Can cause injury or death: DO NOT, under any
circumstances, cut, deform or remove any of the prongs
from the power cord. Do not use with an extension cord.
Failure to comply may cause fire.
CAUTION:
mounting surface must be capable of supporting the
cabinet load, in addition to the added weight of this
63–85 pound (28.6-38.5 kg) product, plus additional
microwave oven loads of up to 50 pounds (22.7 kg) or a
total weight of 113–135 pounds (51.2-61.2 kg).
CAUTION:
cannot be installed in cabinet arrangements such as an
island or a peninsula. It must be mounted to BOTH a top
cabinet AND a back wall.
CAUTION:
injury (back injury or other injuries due to excessive
weight of the microwave) or property damage, you will
need two people to install this microwave.

ELECTRICAL REQUIREMENTS

120 V Models
This product requires a three-prong grounded outlet.
Product rating is 120 volts AC, 60 Hertz, 15 amps, and 1.70
kilowatts. This product must be connected to a supply
circuit of the proper voltage and frequency. Wire size must
conform to the requirements of the National Electrical
Code or the prevailing local code for this kilowatt rating.
The power supply cord and plug should be brought to a
separate 15 to 20 ampere branch circuit single grounded
outlet. The outlet box should be located in the cabinet
above the microwave oven and away from any potential
microwave ducting. The outlet box and supply circuit
should be installed by a qualified electrician and conform
to the National Electrical Code or the prevailing local code.
3
Risk of Electric Shock.
For personal safety, the
For personal safety, this product
To avoid the risk of personal