hit counter script
Download Print this page
Honeywell DUAL TEC DT8050A Quick Installation Manual
Honeywell DUAL TEC DT8050A Quick Installation Manual

Honeywell DUAL TEC DT8050A Quick Installation Manual

Motion sensor with anti-mask

Advertisement

Quick Links

DT8050A DUAL TEC
Détecteur de mouvement DT8050A DUAL TEC
Sensor de Movimiento con Antienmascarmiento DUAL TEC
Sensor de Movimento com Anti-máscara DUAL TEC
*
* Keep Clear / Tenir à l'écart /
Respetar obligatoriamente /
Manter-se afastado
A
#6 x 1 1/4"
(3.5 mm x 32 mm)
Internal EOL Resistor DIP Switches
Résistance interne EOL commutateur DIP
Interruptores DIP Resistencias internas EOL
DIP Switches Resistores internos EOL
ON
EOL
*
KOhm
1
2
®
Motion Sensor with Anti-Mask - Quick Installation Guide
B
2.2 5.6
*
MD
avec Anti-Masque– Guide d'installation rapide
®
DT8050A – Guía Rápida de Instalación
®
DT8050A – Guia rápido de instalação
*
DT8050A
Antienmascaramiento
ON
ON
ON
EOL
KOhm
OFF
1 2 2.2 5.6
AM LED
MAX
PULL
MW
TO DISABLE
LOOK DOWN
SENSITIVITY
W1
LOOK DOWN
#6
(3.5 mm)
B
A
B
X
X
B
Enabled
Activé
Habilitado
Habilitado
Anti-mask
ON
Anti-masque
Anti-máscara
OFF
*Disabled
*Désactivé
*Deshabilitado
*Deshabilitado
Microwave Range Adjustment
Réglage de la portée Hyperfréquence
Ajuste del rango de detección Microondas
Ajuste de Alcance Microondas
*
MAX
MIN
MW
SENSITIVITY
*
Factory default / Réglage usine /
Defecto de fábrica / Padrão de fábrica
A
B
B
A
B
*

Advertisement

loading

Summary of Contents for Honeywell DUAL TEC DT8050A

  • Page 1 DT8050A DUAL TEC ® Motion Sensor with Anti-Mask - Quick Installation Guide Détecteur de mouvement DT8050A DUAL TEC avec Anti-Masque– Guide d'installation rapide Sensor de Movimiento con Antienmascarmiento DUAL TEC ® DT8050A – Guía Rápida de Instalación Sensor de Movimento com Anti-máscara DUAL TEC ®...
  • Page 2 Trouble Tamper Alarm Power 0 VDC - V 30 mA 30 mA 30 mA 18 mA supply 1.8 mA max 25 VDC 25 VDC 25 VDC 9-15 VDC (UL:9.5-15 VDC) LED TBL KOhm 2.2 5.6 WIRING EXAMPLES / EXEMPLES DE CÂBLAGE / EJEMPLOS DE CABLEADO / EXEMPLOS DE CABEAMENTO Control Panel To connect all three outputs (sensor alarm, tamper and trouble/anti-mask) to one...
  • Page 3 To connect the sensor alarm, tamper and trouble/anti-mask outputs to three Control Panel separate zone inputs: The alarm, tamper and trouble/anti-mask are each wired to a Remote Trouble Zone Tamper Zone Alarm separate zone; the control panel differentiates alarm, tamper and trouble/anti-mask Ground +12V Zone Zone...
  • Page 4 Contacte o representante autorizado Honeywell local para obter informações relativas a garantia. P/N 800-13827 03/14 Rev C © 2013 Honeywell International Inc. Honeywell and DUAL TEC are registered trademarks of Honeywell International Inc. All other trademarks are the properties of their respective owners. All rights reserved. Made in China.