hit counter script
Download Print this page
Toshiba 29A3DE Schematic Diagram
Toshiba 29A3DE Schematic Diagram

Toshiba 29A3DE Schematic Diagram

Advertisement

Quick Links

WARNING: BEFORE SERVICING THIS CHASSIS, READ THE "X-RAY RADIATION PRECAUTION", "SAFETY
PRECAUTION" AND "PRODUCT SAFETY NOTICE" ON THE MANUAL FOR THIS MODEL.
CAUTION: The international hazard symbols "*" in the schematic diagram and the parts list designate components
which have special characteristics important for safety and should be replaced only with types identical to those in the
original circuit or specified in the parts list. The mounting position of replacements is to be identical with originals.
Before replacing any of these components, read carefully the PRODUCT SAFETY NOTICE on the MANUAL for this
model. Do not degrade the safety of the receiver through improper servicing.
SCHEMATIC DIAGRAM
MODEL : 29A3DE / 29A3E / 29A3SH
NOTE:
1. RESISTOR
Resistance is shown in ohm [K = 1.000, M = 1.000.000]. All resistors are 1/6W and 5%
tolerance carbon resistor, unless otherwise noted as the following marks.
1/2R = Metal or Metal oxide of 1/2 watt
1/2S = Carbon compsistion of 1/2 watt
1RF = Fuse resistor of 1 watt
10W = Cement of 10 watt
K = ±10%
G = ±2%
F = ±1%
2. CAPACITOR
Unless otherwise noted in schematic, all capacitor values less than 1 are expressed in
?F, and the values more than 1 in pF.
All capacitors are ceramic 50V, unless otherwise noted as the following marks.
Electolytic capacitor
Mylar capacitor
3. The parts indicated with " * " have special characteristics, and should be replaced with identical parts only.
4. Voltages read with DIGITAL MULTI-METER from point indicated to chassing ground, using a color bar signal with all
controls at normal, line voltage 220 volts.
5. Waveforms are taken receiving color bar signal with enough sensitivity.
6. Voltage reading shown are nominal values and may vary ±20% except H.V.

Advertisement

loading

Summary of Contents for Toshiba 29A3DE

  • Page 1 SCHEMATIC DIAGRAM MODEL : 29A3DE / 29A3E / 29A3SH NOTE: WARNING: BEFORE SERVICING THIS CHASSIS, READ THE "X-RAY RADIATION PRECAUTION", "SAFETY PRECAUTION" AND "PRODUCT SAFETY NOTICE" ON THE MANUAL FOR THIS MODEL. 1. RESISTOR Resistance is shown in ohm [K = 1.000, M = 1.000.000]. All resistors are 1/6W and 5% 4.
  • Page 3: Entering To Service Mode

    SERVICE MODE 1. ENTERING TO SERVICE MODE 1) Press o button once on 2) Press o button again to 3) While pressing the o button, Remote Control. keep pressing. press MENU button on TV set. Item Data (Service mode display) 2.
  • Page 4 4. SELECTING THE ADJUSTING ITEMS 1)Every pressing of CHANNEL s button in the service mode changes the adjustment items in the order of table-2. (t button for reverse order) Refer to table-2 for preset data of adjustment mode. (See SETTING & ADJUSTING DATA on page 15) 5.
  • Page 5: Self-Diagnostic Function

    8. SELF DIAGNOSTIC FUNCTION 1) Press “9” button on Remote Control during display of adjustment menu in the service mode. The diagnosis will begin to check if interface among IC’s are executed properly. 2) During diagnosis, the following displays are shown. Indicated color of mode now selected : Green and Red Indicated color of other modes : White...
  • Page 6: Design Mode

    DESIGN MODE 1. ENTERING TO DESIGN MODE 1) Select the Service mode. 2) While pressing (or CALL) button on 3) Press MENU button on TV. Remote and press MENU button on TV. ITEM Press DATA Press (Design mode) (Adjustment mode) When QA02 is initialized, items “OPT0”...

This manual is also suitable for:

29a3e29a3sh