1.8
Drive Unit (Main Motor and Cutter HP Sensor)
(1)
Turn the scanner frame ASSY upside down.
(2)
Remove the adhesive tape to release the CIS harness, motor harness, solenoid har-
ness, and cutter HP sensor harness.
Lower paper chute
Sheath of CIS harness
Cutter HP sensor harness
(3)
Place the scanner frame ASSY rightside up.
(4)
Remove the four screws.
(5)
Fully turn the cutter flange clockwise. Hold the drive unit with your left hand and then
slightly separate its rear edge from the scanner frame ASSY in the direction of arrow
"X" in order to release the boss of the cutter flange from the upper blade.
Solenoid spring
(Left)
Adhesive
tape
Solenoid harness
CIS harness
(M3x6)
"X"
(M3x6)
(M3x8)
Cutter flange
Recording head harness
Motor harness
Upper blade
Boss of cutter flange
IV -18
Scanner frame ASSY
(placed upside down)
Scanner frame
ASSY
(Front)