Digital Fiber Sensor Amplifier FX-505□-C2
Thank you very much for purchasing Panasonic products.
Please read this Instruction Manual carefully and thoroughly for the correct and
optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
WARNING
● Never use this product as a sensing device for personnel protection.
● In case of using sensing devices for personnel protection, use products which
meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel
protection applicable in each region or country.
1
INTENDED PRODUCTS FOR CE MARKING
● This product complies with the following standards / regulations.
<EU Directive>
EMC Directive
<Standards in US / Canada>
ANSI/UL 60947-5-2, CAN/CSA C22.2 No.14
<Regulations in Korea>
S1-G-1-2009, S2-W-5-2009
● Caution about UL recognition
In case requiring conformity of UL listing mark or C-UL listing mark, USe class
2 power supply unit.
● Contact for CE
Panasonic Marketing Europe GmbH Panasonic Testing Center
Winsbergring 15, 22525 Hamburg,Germany
2
PART DESCRIPTION
Sensing output 2
UP key
selection indicator
• Teaching
(Yellow)
• Threshold value
Sensing output 1
fine adjustment
selection indicator
• Select setting items
(Yellow)
Sensing output 1
Digital display
operation indicator
(Green / Red)
(Orange)
MODE indicator: L / D (Yellow)
Sensing output 2
MODE indicator: CUST (Yellow)
operation indicator
(Orange)
MODE indicator: PRO (Yellow)
<Reference>
Pressing down SET key + MODE key for 3 sec : Set key lock or Release key lock
3
MOUNTING
How to connect
1. Fit the rear part of the mounting sec-
tion of the amplifier on a DIN rail.
2. Press down the rear part of the
mounting section of the unit on the
DIN rail and fit the front part of the
mounting section to the DIN rail.
How to remove
1. Push the controller forward.
2. Lift up the front part of the amplifier
to remove it.
How to connect the fiber cable
Be sure to fit the attachment to the fibers first before inserting the fibers to the
amplifier. For details, refer to the instruction manual enclosed with the fibers.
1. Snap the fiber lock lever down till it
stops completely.
2. Insert the fiber cables slowly into the
inlets until they stops. (Note)
3. Return the fiber lock lever to the
original position till it stops.
Note: With the coaxial reflective type fiber, such as , FD-G4 or FD-FM2, insert the single core fiber cable into the
beam-emitting inlet "P" and the multi-core fiber cable into the beam-receiving inlet.
If they are inserted in reverse, the sensing performance will deteriorate.
INSTRUCTION MANUAL
MJE-FX505C2C No.0052-96V
SET key
DOWN key
• Teaching
• Teaching
• C o n f i r m s e t t i n g
• Threshold value fine
contents
adjustment
• Select setting items
MODE key
• Select Modes
• Cancel during setting
• Select sensing output 1/2
by pressing long
2. Press down
1. Fit
35mm width DIN rail
1. Push forward
2. Lift up
3. Return
1. Snap
Fiber lock lever
Fiber for emitter
2. Insert
Fiber for
receiver
SEN TRONIC
056 222 38 18
AG
4
I/O CIRCUIT DIAGRAMS
<FX-505-C2>
(Brown) +V
(Pink) External input
(Black) Sensing output 1
(White) Sensing output 2
(Blue) 0V
(Gray) Monitor current output (4 to 20mA)
<FX-505P-C2>
(Brown) +V
(Black) Sensing output 1
(White) Sensing output 2
(Pink) External input
(Blue) 0V
(Gray) Monitor current output (4 to 20mA)
Note: Make sure to insulate the ends of the unused lead wires.
5
OPERATION PROCEDURE
● The sensing output can be switched to sensing output 1 or sensing output 2
by holding down the mode key.
● The changed settings are not stored if turning the power OFF while setting.
Therefore, confirm the settings by pressing the SET key before turning the
power OFF.
● When turning ON the power, RUN mode is displayed and the digital display
shows the threshold value (green) and the incident light intensity (red).
<RUN mode>
• Displays threshold value (green) and incident light intensity (red).
• Teaching, threshold value fine adjustment and key lock function
can be set.
• For setting method of each function, refer to "
MODE," "
TION," or "
<Sensing output operation mode>
• Select either Light-ON or Dark-ON.
• For the setting, refer to "
MODE."
• The default setting is "
<CUSTOM mode>
• An item set in CUSTOM mode (Response time setting, Emission
power setting and Hysteresis setting) is displayed.
• For details, refer to "
• The default setting is "
<PRO mode>
• Advanced setting can be done.
• For the setting, refer to "
<RUN mode>
mailbox@sentronic.com
www.sentronic.com
Load
Load
+
12 to 24V DC
%
-
Load (0 to 250Ω)
+
12 to 24V DC
%
-
Load
Load
Load (0 to 250Ω)
TEACHING
THRESHOLD VALUE FINE ADJUSTMENT FUNC-
KEY LOCK FUNCTION."
SENSING OUTPUT OPERATION
" (Light-ON).
CUSTOM MODE."
" (response time setting).
PRO MODE."

Advertisement

loading

Summary of Contents for Panasonic FX-505P-C2

  • Page 1 Load (Pink) External input Load (Black) Sensing output 1 Thank you very much for purchasing Panasonic products. 12 to 24V DC Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product. (White) Sensing output 2 Kindly keep this manual in a convenient place for quick reference.
  • Page 2 TEACHING MODE 1-point teaching [Window comparator mode (except sensing output 2) / Hysteresis mode] ● This is method to set the shift amount to the desired value and to set the ● Be sure that detection may become unstable depending on the use environ- threshold range by using the 1-point teaching.
  • Page 3 THRESHOLD VALUE FINE ADJUSTMENT FUNCTION PRO MODE ● Set fine adjustment of threshold value in RUN mode. ● When MODE indicator: PRO (yellow) lights up, PRO mode can be set. ● Also, the threshold value fine adjustment function can be used in forced ON ●...
  • Page 4 ● For communication protocol setting procedure, refer to <PRO4> in “PRO For sales network, please visit our website. MODE OPERATION MANUAL.” PRINTED IN CHINA © Panasonic Industrial Devices SUNX Co., Ltd. 2015 SEN TRONIC 056 222 38 18 mailbox@sentronic.com www.sentronic.com...

This manual is also suitable for:

Fx-505-c2Fx-505 c2 series