A B B M E A S U R E M E N T & A N A L Y T I C S | O P E R A T I N G I N S T R U C T I O N | O I / S C C - U - E N R E V . B
SCC-U
Utility unit
Introduction
SCC-U
Power supply and control unit for use in small
extractive gas analyzer systems
Power distribution for gas analyzers, gas
sampling devices, heated sample probe filter
units, heated sample gas lines
Temperature controllers for heated sample
gas line and heated sample probe filter
(optional)
Solenoid valves for control of automatic
calibration with test gases (optional)
Measurement made easy
Additional information
Additional documentation on SCC-U is available for
download free of charge at www.abb.com/analytical.
Alternatively simply scan this code:

Advertisement

Table of Contents
loading

Summary of Contents for ABB SCC-U

  • Page 1 Introduction Additional information SCC-U • Power supply and control unit for use in small Additional documentation on SCC-U is available for extractive gas analyzer systems download free of charge at www.abb.com/analytical. • Power distribution for gas analyzers, gas Alternatively simply scan this code:...
  • Page 2: Table Of Contents

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B Table of contents Commissioning and operation ....... 16 Safety ................3 Safety instructions for operation ........16 General information and instructions ........3 Checks prior to commissioning .......... 16 Warnings ..................3 Starting-up the utility unit ........... 16 Intended use ................
  • Page 3: Safety

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B 1 Safety General information and instructions Warnings The warnings in these instructions are structured as follows: These instructions are an important part of the product and must be retained for future reference. DANGER...
  • Page 4: Intended Use

    • Safety precautions for working with gases, acids, Improper use condensates, etc. The SCC-U utility unit must not be used in a potentially explosive National regulations atmosphere or in hazardous areas. The regulations, standards and guidelines cited in this operator's manual are applicable in the Federal Republic of Germany.
  • Page 5: Warranty Provisions

    Email: cga@de.abb.com Service address If the information in this Operating Instruction does not cover a particular situation, ABB Service will be pleased to supply additional information as required. Please contact your local service representative. To find your local ABB contact visit: www.abb.com/contacts...
  • Page 6: Design And Function

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B 2 Design and function Overview Front view F00227 1 Heated filter unit temperature controller (option) 5 Heated sample gas line residual current breaker with overcurrent protection (16 A / 0.03 A) 2 Heated sample gas line temperature controller (option)
  • Page 7: Pneumatic Diagrams

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B Pneumatic diagrams See also Internal construction on page 24. Catalog no. 23940-0-1100011X000 Catalog no. 23940-0-1100013X000 Version with 1 solenoid valve for switching ambient air for Version with 3 + 1 solenoid valves for switching up to three test calibration using calibration cells.
  • Page 8: Product Identification

    Risk of electric shock! Scope of delivery Quantity Description SCC-U utility unit with power supply cable, length 3 m 1 to 4 Power supply cables (as per order), length 2 m Plug for connecting the power supply cable of the heated filter...
  • Page 9: Transport And Storage

    In principle, the devices may be stored for an unlimited purposes: period. However, the warranty conditions stipulated in All devices delivered to ABB must be free from any hazardous the order confirmation of the supplier apply. materials (acids, alkalis, solvents, etc.).
  • Page 10: Installation

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B 5 Installation Requirements for the installation site Construction Design Installation location 19 in housing (3 height units) The environmental conditions should be observed (see Ambient conditions). Mounting The device should be installed near the gas analyzer and the Rack mounting on mounting rails.
  • Page 11: Gas Connections

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B Gas connections F00233 1 Outlet to sample gas cooler (standard) 4 Test gas inlet 1 (option) 2 Sample gas inlet (standard) 5 Test gas inlet 2 (option) 3 Outlet to gas sampling probe (option)
  • Page 12: Electrical Connections

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B … 5 Installation Electrical connections Safety instructions for electrical installation WARNING Protective lead connection The protective lead (ground) should be attached to the Risk of injury due to live parts. protective lead connector before any other connection is made.
  • Page 13: Connection On The Device

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B Connection on the device F00234 X20 Power out for filter unit X25 Power out spare X21 Power out for sample gas line X26 Power supply inlet X22 Power out for gas analyzer EL3000 or AO2000...
  • Page 14: Electrical Data

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B … 5 Installation … Electrical connections Electrical Data Input voltage Elektromagnetic compatibility 230 V AC ±10 %, 50 Hz or 115 V AC ±10 %, 60 Hz Tested to EN 61326-1:2013 Note Emitted interference The unit is prepared to support both voltage ranges.
  • Page 15: Connecting The Pt100 Temperature Sensors (Option)

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B Connecting the utility unit to the power supply Connecting the Pt100 temperature sensors (option) 1. Make sure the power supply leads have an adequately The temperature sensors of the heated filter unit (option) and dimensioned (16 A) protective device (breaker).
  • Page 16: Commissioning And Operation

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B 6 Commissioning and operation Safety instructions for operation Starting-up the utility unit When safe operation can no longer be assured NOTICE If it is apparent that safe operation is no longer possible, the...
  • Page 17: Diagnosis / Troubleshooting

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B 7 Diagnosis / Troubleshooting Malfunctions Problem Cause Corrective action Utility unit not working Power supply interrupted Reconnect the power supply No power supply in external device Utility unit not activated Turn on main switch...
  • Page 18: Maintenance / Repair

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B 8 Maintenance / Repair Safety instructions Cleaning If necessary, clean the outside of the device with a damp cloth CAUTION and mild cleaning agents. Make sure that no water drops Risk of injury penetrate into the device.
  • Page 19: Dismounting And Disposal

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B 9 Dismounting and disposal Disposal Dismounting Note WARNING Products that are marked with the adjacent symbol Risk of injury due to process conditions. may not be disposed of as unsorted municipal waste The process conditions, for example high pressures and (domestic waste).
  • Page 20: Specification

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B 10 Specification 11 Additional documents Note Note The device data sheet is available in the ABB download area at All documentation, declarations of conformity, and certificates www.abb.de/analytical. are available in ABB's download area. www.abb.com/analytical...
  • Page 21: Appendix

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B 12 Appendix Return form Statement on the contamination of devices and components Repair and/or maintenance work will only be performed on devices and components if a statement form has been completed and submitted.
  • Page 22: Technical Drawings

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B … 12 Appendix Technical drawings Dimensions...
  • Page 23 SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B...
  • Page 24: Internal Construction

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B … 12 Appendix … Technical drawings Internal construction...
  • Page 25: Pneumatic Diagram

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B Pneumatic diagram...
  • Page 26: Wiring Diagram

    SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B … 12 Appendix … Technical drawings Wiring diagram Page 1 of 4...
  • Page 27 SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B Page 2 of 4...
  • Page 28 SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B … 12 Appendix … Technical drawings Page 3 of 4...
  • Page 29 SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B Page 4 of 4...
  • Page 30 SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B Notes...
  • Page 31 SCC-U UTILITY UNIT | OI/SCC-U-EN REV. B Notes...
  • Page 32 We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents – in whole or in parts – is forbidden without prior written consent of ABB. © ABB 2023...

Table of Contents