Page 1
Model 940 Proximity Reader Installation Manual...
Page 2
GE and the GE monogram are registered trademarks of General Electric. and patents Model 940 Proximity Reader product and logo are trademarks of GE Security. Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products.
Introduction Introduction This manual is an installation guide for the GE Model 940 proximity reader which features two-state supervision that continuously monitors for closed and open circuit conditions at door contacts and request to exit (REX) connections. An internal tamper switch automatically alerts security personnel if the reader is violated.
Model 940 Reader Installation Manual Safety Radio interference WARNING: This is an FCC Class A product. In a domestic environment, this product may cause radio interference, in which case, the user may be required to take adequate measures. Electrostatic discharge (ESD) precaution...
12 VDC operation. • A clear, logical user interface with tri-color LED and beeper. • Rugged molded ABS construction with backplate. • Cover removal and off-the-wall tamper detection. 1. The new Model 940 reader (single LED) does not support Proximity Perfect cards.
Model 940 Reader Installation Manual System requirements Host software ® • Secure Perfect Edition 3.0 or later ™ • Picture Perfect 1.7 or later Microcontrollers • Micro/5-PX with 2RP or 8RP • Micro/5-PXN with 2RP or 8RP • M5PXNplus • Micro/PX-2000 •...
Technical specifications Technical specifications For UL compliant installation notes, refer to UL listed installations on page 26 Operating temperature -31 F (-35 C) to +150 F (+66 C) range Relative humidity 5% to 95% (non-condensing) Physical dimensions 4.75" (121 mm) x 2.9" (74 mm) x 0.90" (23 mm) (HxWxD) Index of protection IP51...
Model 940 Reader Installation Manual Parts list • Model 940 Reader with backplate (gray or black) • Optional installation wrench Refer to the GE price list for part numbers and ordering information.
Installation overview Installation overview The following steps are general instructions for installing the 940 reader. Each step is explained in further detail in the sections that follow. 1. Mount the reader. Refer to “Mounting the reader” on page 8. 2. Configure the reader Refer to “Configuring the reader”...
Model 940 Reader Installation Manual Mounting the reader The reader comes with a backplate suitable for mounting directly onto standard U.S. electrical gang boxes. The reader may also be mounted directly onto a hollow wall. Important: • Readers should not be mounted within three feet of a computer terminal.
Mounting the reader Figure 1. Off-the-wall tamper activation To activate the off-the-wall tamper feature, remove the key on the backplate prior to mounting. Figure 2. Recommended additional mounting instructions for off-the-wall tamper switch activation...
For unsupervised F/2F or Wiegand 40-bit format output, you must configure the reader using the Reader Configuration Card Kit. Refer to the documentation included in the kit for detailed instructions. The kit can be ordered at no cost from the GE Security price list.
Connect the reader to the micro Connect the reader to the micro The Model 940 Reader is supplied with a convenient removable 9-pin connector as shown in Figure 5 below. Refer to the following sections for more information on connecting the reader: •...
The table below shows the pinouts for connecting the reader to the microcontroller. Connector J1, pin 1 is to the right as you view the connector from behind the reader. See Figure 5, “Model 940 Reader,” on page 13. Table 1.
Connect the reader to the micro Wiring diagrams See the following wiring diagrams for details on connecting the reader to the microcontroller: • “Supervised F/2F wiring diagram” on page 16 • “Unsupervised F/2F wiring diagram” on page 18 • “Wiegand wiring diagram” on page 20...
Model 940 Reader Installation Manual Testing the reader Follow the steps below to verify that the reader is working correctly. WARNING: It is important to ensure all connections are made prior to applying power. 1. Check the following: • Proper cabling and electrical connections exist between the reader and the microcontroller.
Testing the reader c. Present a card to the reader. Observe that the reader behaves as described in the section “Indicators” on page 23 d. Observe that the green LED turns on, indicating a valid access has been granted by the host. e.
Model 940 Reader Installation Manual Regulatory approvals Manufacturers Declaration of Conformity Product Identification: 430084001/2 Model/type: Model 940 BOM revision level Category (description): Proximity Reader Brand: GE Security Manufacturer: GE Security Suite 100 791 Park of Commerce Blvd. Boca Raton, Florida 33487 EU Representative: GE Security B.V.
Regulatory approvals CE/FCC compliance To make the Model 940 Reader installation CE and FCC compliant, the cable connecting the reader to the micro must have its shield grounded at the micro, according to one of the methods specified in the figures below.
Page 30
Operating Temperature Range: +32 F (+0 C) to +120 F (+49 C) • Relative Humidity: 85% • The Model 940 reader was evaluated by UL for indoor use only. • Request to exit (REX) terminals on the reader are not to be connected for UL listed installations.
Page 31
NX-8E panel: Connect to the OH2000E Receiver using a dial-up connection. Note: The NX-8E keypad must be installed adjacent to the Model 940 reader in order to be UL compliant. OH2000E Receiver: Connect to the Picture Perfect server, using a serial line RS-232 connection.
Page 32
Model 940 Reader Installation Manual Notes...
Page 34
Model 940 Reader Installation Manual Notes...
Page 36
Security U.S. T 888 GE SECURITY (1 888 437 3287) F 561 998 6224 Asia T 852 2907 8108 F 852 2142 5063 Australia T 61 3 9259 4700 F 61 3 9259 4799 Europe T 32 2 725 11 20...