System control line voltage polarity sense models (17 pages)
Summary of Contents for Honeywell Maxon SMA11
Page 1
MANUFACTURER AND IMPORTER ADDRESSES Below are the addresses and contact information for the Honeywell – Maxon manufacturing location and European sales office. The European sales office serves as the importer and EU manufacturer's representative under the EU New Legislative Framework (NLF).
Page 2
GAS ELECTRO-MECHANICAL VALVES WARNING Nameplate and abbreviations The installation, operation and maintenance instructions contain important information that Consult the nameplate of your valve. This lists the must be read and followed by anyone operating maximum operating pressure, temperature limitations, or servicing this product. Do not operate or voltage requirements and service conditions of your service this equipment unless the instructions specific valve.
GAS ELECTRO-MECHANICAL VALVES INSTALLATION 6. All access cover plate screws should be tightened using a torque wrench in an alternate cross-corner tightening pattern to the values shown in “Table 1 - 1. A gas filter or strainer of 40 mesh (0.6 mm) or Torque specifications”...
Page 5
GAS ELECTRO-MECHANICAL VALVES Agency approvals and certifications General Purpose Valves Non-Incendive/Non-Sparking Valves SMA11, SMM11, CMA11, SMA12, SMM12, SMA22, CMA22, CMM11, SMA21, SMM21, CMA12, CMM12, SMM22, CMM22 CMA21, HMA11 Standards Markings Standards Markings Class I, Div. 2, Groups ABCD FM 7400 Class II, Div.
Page 6
GAS ELECTRO-MECHANICAL VALVES Valve cycle requirements This is based on the standards that MAXON valves are approved to and the corresponding minimum number of cycles to be completed without failure as shown in the chart below. UL (UL 429) CSA (CSA 6.5) FM (FM 7400) European (EN161) <= DN25 200,000...
Page 7
GAS ELECTRO-MECHANICAL VALVES VALVE MODEL NUMBER DESCRIPTION Every MAXON gas electro-mechanical valve can be accurately identified by the model number shown on the valve nameplate. The example below shows a typical gas electro-mechanical valve model number, along with the available choices for each item represented in the model number.
Page 8
GAS ELECTRO-MECHANICAL VALVES ACTUATOR ASSEMBLY ROTATION 13. Replace and secure terminal block cover plate and place valve in service. WARNING FIELD INSTALLATION OF VALVE POSITION SWITCH MAXON electro-mechanical valves should be ordered in a configuration compatible with planned piping. If valve orientation is not correct, General the actuator assembly can be rotated in 90°...
GAS ELECTRO-MECHANICAL VALVES TO CLUTCH #1 BLACK TO TERMINAL #1 BLACK TO MOTOR #3 BLACK TO TERMINAL #3 Reference mounting bracket A Reference mounting bracket B Switches mount on support stand Fig. 2 Fig. 1 Automatic reset actuator Fig. 3 Manual reset actuator DN65 C - DN100 C Models &...
GAS ELECTRO-MECHANICAL VALVES MAINTENANCE INSTRUCTIONS Actuator assembly components require no field lubrication and should never be oiled. MAXON electro-mechanical valves are endurance tested Auxiliary switches, solenoids, motors, clutches or circuit far in excess of the most stringent requirements of the boards may be replaced in the field.
GAS ELECTRO-MECHANICAL VALVES Special Conditions of Safe Use: Product contains greater than 10% Aluminum. MA Valves IEC 61508 Failure Rates in FIT* Failure Category FC-D/SR 0 Fit 797 FIT 0 FIT 1170 FIT FC-F/SR 0 FIT 1342 FIT 0 FIT 625 FIT...
Page 12
GAS ELECTRO-MECHANICAL VALVES For More Information The Honeywell Thermal Solutions family of products includes Honeywell Combustion Safety, Eclipse, Exothermics, Hauck, Kromschröder and Maxon. To learn more about our products, visit ThermalSolutions.honeywell.com or contact your Honeywell Sales Engineer. Honeywell MAXON branded products...