Contents 1 About your system....................8 ........................8 Supported configuration ..................... 8 Front-panel features and indicators ..........................10 LCD panel features ..........................10 Home screen ............................ 11 Setup menu ............................11 View menu ........................... 11 Diagnostic indicators ........................13 Hard drive indicator codes ......................14 iDRAC Direct LED indicator codes ....................
Page 4
...................... 35 Miscellaneous Settings details ...........................36 About Boot Manager ........................ 36 Entering Boot Manager ......................36 Boot Manager main menu ........................36 Changing the boot order .......................37 Choosing the system boot mode .................... 37 Assigning a system and setup password ................ 38 Using your system password to secure your system ........
Page 5
............57 Installing a 3.5-inch hot swappable hard drive carrier blank ................57 Removing a hot swappable hard drive carrier ................58 Installing a hot swappable hard drive carrier ..........59 Removing a hot swappable hard drive from a hard drive carrier ......60 Installing a hot swappable hard drive into a hot swappable hard drive carrier ............................61 Cooling fans...
Page 6
........................104 Warning messages ........................104 Diagnostic messages ..........................104 Alert messages 6 Using system diagnostics................105 ....................105 Dell Embedded System Diagnostics ..............105 When to use the Embedded System Diagnostics ........... 105 Running the Embedded System Diagnostics from Boot Manager...
Page 7
....105 Running the Embedded System Diagnostics from the Dell Lifecycle Controller ......................106 System diagnostic controls 7 Jumpers and connectors................107 ......................107 System board jumper settings ........................ 108 System board connectors ......................110 Disabling a forgotten password 8 Getting help....................... 111 ..........................
About your system The Dell XC430 system is web-scale converged appliance based on the Dell PowerEdge R430 that supports two Intel Xeon E5-2600 v3 processors, up to 12 DIMMs, and four hard drives or solid-state drives (SSDs). Supported configuration Table 1. Supported configuration...
Page 9
USB regular USB port or provide access to the iDRAC port features. For more information, see the iDRAC User’s Guide available at Dell.com/idracmanuals. USB connector Allows you to connect USB devices to the system. The port is USB 2.0-compliant.
The system's LCD panel provides system information and status and error messages to indicate if the system is operating correctly or if the system needs attention. For more information about error messages, see the Dell Event and Error Messages Reference Guide at dell.com/esmmanuals. •...
SEL. This is useful when trying to match an LCD message with an SEL entry. Select Simple to display LCD error messages in a simplified user-friendly description. For more information about error messages, see the Dell Event and Error Messages Reference Guide at Dell.com/idracmanuals. Set home Select the default information to be displayed on the LCD Home screen.
Page 12
For if any error exists (for more information about the error example, a failed fan or hard messages, see the Dell Event and drive). Error Messages Reference Guide at Dell.com/openmanagemanuals > OpenManage software.
Icon Description Condition Corrective action Reinstall the card. If the issue persists, seeGetting help. NOTE: For more information about supported PCIe cards, seeExpansion card installation guidelines. Hard drive indicator codes Figure 3. Hard drive indicators Hard drive activity indicator Hard drive status indicator Hard drive NOTE: If the hard drive is in Advanced Host Controller Interface (AHCI) mode, the status indicator (on the right side) does not function and remains off.
Drive-status indicator pattern Condition Blinks amber four times per second Drive failed Blinks green slowly Drive rebuilding Steady green Drive online Blinks green three seconds, amber three seconds, Rebuild aborted and turns off six seconds iDRAC Direct LED indicator codes This topic describes about the iDRAC Direct LED indicator codes.
The following table describes about iDRAC Direct activity when configuring iDRAC Direct using your laptop and cable (Laptop connect). Table 7. iDRAC Direct LED indicator pattern Condition Solid green for two seconds Indicates that the laptop is connected. Flashing green (on for two seconds and off for Indicates that the laptop connected is recognized.
Page 16
Item Indicator, Button, or Icon Description Connector USB connector Allow you to connect USB devices to the system. The port is USB 2.0-compliant. USB connector Allow you to connect USB devices to the system. The port is USB 3.0-compliant. System identification button The identification buttons on the front and back panels can be used to locate a particular system within a rack.
NIC indicator codes Figure 6. NIC indicators link indicator activity indicator Table 9. NIC indicators Conventi Indicator Indicator code Link and activity indicators are off The NIC (network interface card) is not connected to the network. Link indicator is green The NIC is connected to a valid network at its maximum port speed (1 Gbps).
Page 18
NOTE: For AC PSUs, use only PSUs with the Extended Power Performance (EPP) label on the back. Mixing PSUs from previous generations of Dell PowerEdge servers can result in a PSU mismatch condition or failure to turn on. Flashing amber...
Power is not connected. Documentation references For information about the Dell documents, see the Support Matrix specific for your product. For information about the Nutanix documents that applies to a specific release of Nutanix solution software, see the Support Matrix specific for your product.
Server LCD panel You can configure iDRAC IP by using: iDRAC Web Interface. For more information about setting up and configuring iDRAC, see the Integrated Dell Remote Access Controller User's Guide at Dell.com/idracmanuals. Remote Access Controller ADMin (RACADM). For more information, see the RACADM Command Line Interface Reference Guide and the Integrated Dell Remote Access Controller User's Guide at Dell.com/idracmanuals.
For more information, see the Integrated Dell Remote Access Controller User’s Guide at Dell.com/idracmanuals. You can also remotely monitor and manage the server by using the Dell OpenManage Server Administrator software application and OpenManage Essentials systems management console. For more information, go to Dell.com/openmanagemanuals.
• Dell Lifecycle Controller Dell Lifecycle Controller allows you to perform useful tasks such as configuring BIOS and hardware settings, deploying operating system, updating drivers, and saving hardware profiles. For more information about Dell Lifecycle Controller, see the documentation at Dell.com/idracmanuals.
Enables you to enter PXE boot About System Setup Using System Setup, you can configure the BIOS settings, iDRAC settings, and device settings of your system. NOTE: There are a several generic server settings that appear during system setup that do not apply to this system, such as RAID or UEFI.
UEFI (Unified Extensible Firmware Interface). You can enable or disable various iDRAC parameters by using the iDRAC settings utility. For more information about this utility, see Integrated Dell Remote Access Controller User’s Guide at Dell.com/idracmanuals. Device Settings Enables you to configure device settings.
Operating Mode Advanced ECC Mode, Mirror Mode, Spare Mode, Spare with Advanced ECC Mode, Dell Fault Resilient Mode and Dell NUMA Fault Resilient Mode. This option is set to Optimizer Mode by default. NOTE: The Memory Operating Mode option can have different default and available options based on the memory configuration of your system.
NOTE: This option is only available on certain stock keeping units (SKUs) of the processors. X2Apic Mode Enables or disables the X2Apic mode. Dell Controlled Controls the turbo engagement. Enable this option only when System Profile is set Turbo to Performance.
NOTE: Depending on the number of installed CPUs, there may be up to four processor listings. Number of Cores Controls the number of enabled cores in each processor. This option is set to All per Processor by default. Processor 64-bit Specifies if the processor(s) support 64-bit extensions.
Page 28
Model Specifies the drive model of the selected device. Drive Type Specifies the type of drive attached to the SATA port. Capacity Specifies the total capacity of the hard drive. This field is undefined for removable media devices such as optical drives.
For AHCI or RAID mode, BIOS support is always enabled. Model Specifies the drive model of the selected device. Drive Type Specifies the type of drive attached to the SATA port. Capacity Specifies the total capacity of the hard drive. This field is undefined for removable media devices such as optical drives.
CAUTION: Switching the boot mode may prevent the system from booting if the operating system is not installed in the same boot mode. If the operating system supports UEFI, you can set this option to UEFI. Setting this field to BIOS allows compatibility with non-UEFI operating systems. This option is set to BIOS by default.
ISCSI Device n (n = Enables or disables the iSCSI device. When disabled, a UEFI boot option is created 1 to 4) for the iSCSI device automatically. Integrated Devices details The Integrated Devices screen details are explained as follows: USB 3.0 Setting Enables or disables the USB 3.0 support.
Memory Mapped Enables or disables the support for PCIe devices that need large amounts of I/O above 4 GB memory. This option is set to Enabled by default. Slot Disablement Enables or disables the available PCIe slots on your system. The slot disablement feature controls the configuration of PCIe cards installed in the specified slot.
Page 33
Custom, the BIOS automatically sets the rest of the options. You can only change the rest of the options if the mode is set to Custom. This option is set to Performance Per Watt Optimized (DAPC) by default. DAPC is Dell Active Power Controller.
NOTE: This option can be disabled only if the C States option in the Custom mode is set to disabled. NOTE: When C States is set to Enabled in the Custom mode, changing the Monitor/Mwait setting does not impact the system power or performance. System Security Settings details The System Security Settings screen details are explained as follows: Intel AES-NI...
specification. When set to Controlled, selected UEFI variables are protected in the environment and new UEFI boot entries are forced to be at the end of the current boot order. Secure Boot Enables Secure Boot, where the BIOS authenticates each pre-boot image by using the certificates in the Secure Boot Policy.
Launch System Allows you to access the System Setup. Setup Launch Lifecycle Closes the Boot Manager and invokes the Dell Lifecycle Controller program. Controller System Utilities Opens system utilities menu such as system diagnostics and UEFI shell. Changing the boot order You may have to change the boot order if you want to boot from a USB key or an optical drive.
NOTE: Operating systems must be UEFI-compatible to be installed from the UEFI boot mode. DOS and 32-bit operating systems do not support UEFI and can only be installed from the BIOS boot mode. NOTE: For the latest information on supported operating systems, go to Dell.com/ossupport. Assigning a system and setup password Prerequisites NOTE: The password jumper enables or disables the System Password and Setup Password features.
• Only the following special characters are allowed: white space, (”), (+), (,), (-), (.), (/), (;), ([), (\), (]), (`). A message prompts you to reenter the system password. Reenter the system password and click OK. Select Setup Password, enter your system password and press Enter or Tab. A message prompts you to re-enter the setup password.
The Dell Lifecycle Controller can be started during the boot sequence and can function independently of the operating system. NOTE: Certain platform configurations may not support the full set of features provided by the Dell Lifecycle Controller. For more information about setting up the Dell Lifecycle Controller, configuring hardware and firmware, and deploying the operating system, see the Dell Lifecycle Controller documentation at Dell.com/...
On the System Setup Main Menu page, click iDRAC Settings. The iDRAC Settings screen is displayed. Changing the Thermal settings The iDRAC Settings utility enables you to select and customize the thermal control settings for your system. Enter the iDRAC Settings utility. Under iDRAC Settings →...
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Steps Install the system cover. If removed, install the optional front bezel. Reconnect the peripherals and connect the system to the electrical outlet. Turn on the system, including any attached peripherals. Recommended tools You will need the following items to perform the procedures in this section: •...
Steps Rotate the latch release lock counter clockwise to the unlocked position. Lift the latch toward the back of the system. The system cover slides back and the tabs on the system cover disengage from the slots on the chassis. NOTE: The position of the latch may vary depending on the configuration of your system.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Next steps Follow the procedure listed in After working inside your system. System memory Your system supports DDR4 registered DIMMs (RDIMMs). NOTE: MT/s indicates DIMM speed in MegaTransfers per second. Memory bus operating frequency can be 2133 MT/s, 1866 MT/s, 1600 MT/s, or 1333 MT/s depending on the following factors: •...
Page 48
Figure 11. System memory Memory channels are organized as follows: Processor 1 channel 0: memory sockets A1 and A5 channel 1: memory sockets A2 and A6 channel 2: memory sockets A3 and A7 channel 3: memory sockets A4 and A8 Processor 2 channel 0: memory sockets B1...
channel 1: memory sockets B2 channel 2: memory sockets B3 channel 3: memory sockets B4 The following table shows the memory populations and operating frequencies for the supported configurations. Table 11. System memory DIMM DIMMs Operating Maximum DIMM Rank/ Voltage Type Populated/ Frequency (in MT/s)
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Page 51
WARNING: The memory modules are hot to touch for some time after the system has been powered down. Allow the memory modules to cool before handling them. Handle the memory modules by the card edges and avoid touching the components or metallic contacts on the memory module.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Figure 13. Installing the memory module memory module alignment key memory module socket ejector (2) Next steps Install the cooling shroud. Follow the procedure listed in After working inside your system. Press F2 to enter System Setup, and check the System Memory setting. The System Memory Size indicates the installed memory.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Half Height NOTE: The PCIE_G3_X8 and PCIE_G3_X16 are the two different types of risers supported on Dell XC430 systems. You can install an expansion card on the system board only using expansion-card riser. NOTE: The expansion cards are not hot-swappable.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 68
Follow the procedure listed in Before working inside your system.. Steps Locate the internal dual SD module on the system board. If installed, remove the SD cards. Hold the plastic pull tab and pull the dual SD module out of the system board. Figure 19.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Page 70
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Page 72
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Page 73
Figure 21. Processor shield opening and closing lever sequence close first socket release lever lock icon processor open first socket release lever unlock icon Position your thumb firmly over the processor open first socket-release lever near the unlock icon and release the lever from the locked position by pushing down and out from under the tab. Similarly, position your thumb firmly over the processor close first socket-release lever near the lock icon and release the lever from the locked position by pushing down and out from under the tab.
Page 74
Figure 22. Removing and installing a processor close first socket-release lever pin-1 indicator of processor processor slot (4) processor shield open first socket-release lever socket socket keys (4) Hold the tab on the processor shield and rotate the processor shield upward until the open first socket-release lever lifts up.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 76
CAUTION: Do not use force to seat the processor. When the processor is positioned correctly, it engages easily into the socket. b. Align the pin-1 indicator of the processor with the triangle on the socket. c. Place the processor on the socket such that the slots on the processor aligns with the socket keys on the socket.
NOTE: The PSUs must be of the same type and have the same maximum output power. NOTE: For AC PSUs, use only PSUs with the Extended Power Performance (EPP) label on the back. Mixing PSUs from previous generations of Dell PowerEdge servers can result in a PSU mismatch condition or failure to turn on.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
While booting, press F2 to enter the System Setup and ensure the battery is operating properly. Enter the correct time and date in the System Setup Time and Date fields. Close the System Setup page. Hard-drive backplane Dell XC430 system configuration supports 3.5-inch (x4) SAS/SATA backplane.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that came with the product.
Page 90
Follow the procedure listed in After working inside your system. Import your new or existing iDRAC Enterprise license. For more information, see the Integrated Dell Remote Access Controller User’s Guide available at Dell.com/support/home. Ensure that you: Use the Easy Restore feature to restore the service tag. See Restoring the Service Tag using Easy Restore.
Service Tag. Once the Service Tag is entered, it cannot be updated or changed. Click Ok. Import your new or existing iDRAC Enterprise license. For more information, see Integrated Dell Remote Access Controller User's Guide, at Dell.com/ idracmanuals. Restoring the Service Tag using Easy Restore Use the Easy Restore feature if you do not know the Service Tag of your system.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
For more information on initializing the TPM, go to http://technet.microsoft.com/en-us/library/ cc753140.aspx. The TPM Status changes to Enabled, Activated. Re-enabling the TPM for TXT users While booting your system, press F2 to go to System Setup. On the System Setup Main Menu screen, click System BIOS → System Security . From the TPM Security option, select On with Pre-boot Measurements.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
If the problem is resolved, restart the system, enter the System Setup, and check if the non- functioning USB ports are enabled. Check if USB 3.0 is enabled in System Setup. If enabled, disable it and see if the issue is resolved (older operating systems may not support USB 3.0).
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
System messages For a list of event and error messages generated by the system firmware and agents that monitor system components, see the Dell Event and Error Messages Reference Guide at Dell.com/idracmanuals. Warning messages A warning message alerts you to a possible problem and prompts you to respond before the system continues a task.
Using system diagnostics If you experience a problem with your system, run the system diagnostics before contacting Dell for technical assistance. The purpose of running system diagnostics is to test your system hardware without requiring additional equipment or risking data loss. If you are unable to fix the problem yourself, service and support personnel can use the diagnostics results to help you solve the problem.
Displays a time-stamped log of the results of all tests run on the system. This is displayed if at least one event description is recorded. For information about embedded system diagnostics, see the ePSA Diagnostics Guide (Notebooks, Desktops and Servers) available at Dell.com/support/home.
Jumpers and connectors System board jumper settings For information on resetting the password jumper to disable a password, see Disabling a forgotten password. Table 17. System board jumper settings Jumper Setting Description PWRD_EN The password reset feature is enabled (pins 2–4). BIOS local access is unlocked at the next AC power cycle.
System board connectors Figure 33. System board jumpers and connectors Table 18. System board jumpers and connectors Item Connector Description SYS_PWR_CONN (P1) 24-pin power connector FB_USB Front-panel USB connector PIB_CONN Power interposer board connector SATA_CDROM SATA connector CDROM MiniPERC PCIE_G3_X8 (CPU1) Mini PERC card connector SATA_TBU SATA connector tape backup unit...
Page 109
Item Connector Description BATTERY Battery connector TPM_MODULE Trusted platform module connector J_PSWD_NVRAM For more information, see System board jumper settings SLOT3 PCIE_G3_X16(CPU1) PCIe card connector 3 SLOT2 PCIE_G3_X16(CPU1) PCIe card connector 2 NOTE: This system supports two different types of risers: PCIE_G3_X8 and PCIE_G3_X16.
Damage due to servicing that is not authorized by Dell is not covered by your warranty. Read and follow the safety instructions that are shipped with your product.
For contact details of Dell Global Technical Support: a. Click Global Technical Support. b. The Technical Support page is displayed with details to call, chat, or e-mail the Dell Global Technical Support team. Dell SupportAssist For an enhanced Support Experience, Dell recommends installing and configuring Dell SupportAssist.
Use the Quick Resource Locator (QRL) to get immediate access to system information and how-to videos. This can be done by visiting Dell.com/QRL or by using your smartphone or tablet and a model specific Quick Resource (QR) code located on your Dell system. To try out the QR code, scan the following image.