hit counter script
Panasonic AV-HS60U1P Operating Instructions Manual

Panasonic AV-HS60U1P Operating Instructions Manual

Hide thumbs Also See for AV-HS60U1P:

Advertisement

Quick Links

Operating Instructions
This manual is an excerpted version of the Operating Guide. For more information, please visit the
Panasonic website (http://pro-av.panasonic.net/en/manual/index.html), and refer to the Operating Guide
(PDF).
Before operating this product, please read the instructions carefully and save this manual for future use.
Please carefully read the "Read this first!" (P. 2 to 7) of this Manual before use.
FJ0214MS2032 -YI
Printed in Japan
AV-HS60U1P
Model No.
AV-HS60U2P
Model No.
AV-HS60U1E
Model No.
AV-HS60U2E
Model No.
Excerpted Version
Main Frame
ENGLISH
VQT5J54-2

Advertisement

Table of Contents
loading

Summary of Contents for Panasonic AV-HS60U1P

  • Page 1 Model No. This manual is an excerpted version of the Operating Guide. For more information, please visit the Panasonic website (http://pro-av.panasonic.net/en/manual/index.html), and refer to the Operating Guide (PDF). Before operating this product, please read the instructions carefully and save this manual for future use.
  • Page 2: Read This First! (For Av-Hs60U1P/Av-Hs60U2P)

    Read this first! (For AV-HS60U1P/AV-HS60U2P) Read this first! (For AV-HS60U1P/AV-HS60U2P) indicates safety information. WARNING: WARNING: This equipment is compliant with Class A of Installation should only be performed by qualified CISPR 32. installation personnel. In a residential environment this equipment may Improper installation may result in the entire cause radio interference.
  • Page 3 Main Frame is drawn out. Operation at a voltage other than 120 V AC may require the use of a different AC plug. Please contact either a local or foreign Panasonic authorized service center for assistance in selecting an alternate AC plug.
  • Page 4 Read this first! (For AV-HS60U1P/AV-HS60U2P) WARNING: THIS PRODUCT CONTAINS A COIN BATTERY Keep coin battery out of the reach of infants and small children whether the battery is new or used. Severe or fatal injuries can occur within 2 hours of ingestion. Seek medical attention immediately.
  • Page 5: Read This First! (For Av-Hs60U1E/Av-Hs60U2E)

    Read this first! (For AV-HS60U1E/AV-HS60U2E) Read this first! (For AV-HS60U1E/AV-HS60U2E) indicates safety information. CAUTION: WARNING: Do not remove panel covers by unscrewing. Installation should only be performed by qualified To reduce the risk of electric shock, do not remove installation personnel. the covers.
  • Page 6 4-1-62 Minoshima, Hakata-ku, Fukuoka 812-8531, Japan Importer: Panasonic Connect Europe GmbH Authorized Representative in EU: Panasonic Testing Centre Winsbergring 15, 22525 Hamburg, Germany Importer for UK: Panasonic Connect UK, a branch of Panasonic Connect Europe GmbH, Maxis 2, Western Road, Bracknell, Berkshire, RG12 1RT...
  • Page 7 Back-up Battery (Lithium Battery) • For the removal of the battery for disposal at the end of its service life, please consult your dealer. ІНФОРМАЦІЯ ПРО ПІДТВЕРДЖЕННЯ ВІДПОВІДНОСТІ ПРОДУКТУ Виробник: Panasonic Connect Co., Ltd. Панасонік Коннект Ко., Лтд. Адреса виробника: Fukuoka, Japan Фукуока...
  • Page 8: Table Of Contents

    Abbreviations The following abbreviations are used in this document. f The model numbers of the Main Frames AV-HS60U1P/AV-HS60U2P, AV-HS60U1E/AV-HS60U2E are described as “AV-HS60U1”/“AV-HS60U2”. f The model numbers of the Control Panels AV-HS60C1P/AV-HS60C2P, AV-HS60C1E/AV-HS60C2E are described as “AV-HS60C1”/“AV-HS60C2”. f The model numbers of the Control Panels AV-HS60C4P and AV-HS60C4E are described as “AV-HS60C4”.
  • Page 9: Overview

    Refer to the Operating Guide of the AV-HS6000 series. Accessories f AC cable - AV-HS60U1P: 1 cable, AV-HS60U2P: 2 cables - AV-HS60U1E: 2 cables, AV-HS60U2E: 4 cables f Rack-mounted rear panel support bracket f Screws for the rack-mounted rear panel support bracket: 8 screws...
  • Page 10: Part Names And Functions

    Part Names and Functions Part Names and Functions Front panel Power supply 2 Power supply 1 1 Alarm indicator <ALARM> Lights up when the cooling fan of the Main Frame AV-HS60U1/AV-HS60U2 has stopped or when there are problems (voltage declines) with the power supply.
  • Page 11 Part Names and Functions 5 <PANEL> terminal (connector: RJ-45/signal: 100Base-TX) Connects the Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4. 6 <REF> terminal (connector: BNC×2/signal: Genlock) Loop-through output in the external sync mode. If the loop-through output is not going to be used, provide a 75 Ω termination. Black burst signals are output from both terminals in the internal sync mode.
  • Page 12: Notification When The Power Is Turned On For The First Time

    Notification when the power is turned on for the first time Notification when the power is turned on for the first time When using the products for the first time, connect the Control Panel AV-HS60C1/AV-HS60C2/AV-HS60C4 to the <PANEL> terminal of the Main Frame AV-HS60U1/AV-HS60U2, and then turn on the power.
  • Page 13: Specifications

    Specifications Perform the version update of the software if necessary. Check the latest software information in the following website, and perform the software version update if necessary. https://pro-av.panasonic.net/ (English only) Specifications Power supply AC d 100 V to 240 V, 50 Hz/60 Hz...
  • Page 14 Specifications <SDI OUT 1> to <SDI OUT 16> During Standard mode terminals 16 lines (two distribute outputs per line) f Connectors: BNC×32 f ME1PGM, ME1PVW, ME1CLN, ME1KEYPVW, ME2PGM, ME2PVW, ME2CLN, ME2KEYPVW, DSKPGM1, DSKPGM2, DSKPVW1, DSKPVW2, DSK1CLN, DSK2CLN, DSK3CLN, DSK4CLN, SEL KEYPVW, MV1 to MV4, and AUX1 to AUX16 can be assigned.
  • Page 15 Specifications Synchronous terminal <REF> terminal In Genlock mode: Black burst or Tri-level Sync input signals (with loop-through) f If the loop-through output is not used, provide a 75 Ω termination. In internal sync mode: Black burst output signal ×2 f Connector: BNC f Same field frequencies as those of the system formats supported f In the 1080/24PsF and 1080/23.98PsF formats, only Genlock mode supported f In the 1080/23.98PsF format, black burst signals with 10 Field ID (SMPTE318M standard compliant) or Tri-level Sync...
  • Page 16 Note for the battery symbol (bottom symbol): This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement set by the Directive for the chemical involved. Web Site: https://pro-av.panasonic.net/en/ © Panasonic Connect Co., Ltd. 2014 - 2022...