Turbocharger rating plate

Fig. 6: Rating plate
Operating limits
01 Turbocharger operating limits at engine overload (110 %).
In test rig operation only, unless otherwise agreed with the en-
ginebuilder.
02 Turbocharger operating limits during operation
Recommended inspection and replacement intervals of turbocharger components
03 Inspection interval of plain bearings in 1000 h
04 Replacement interval of compressor in 1000 h
05 Replacement interval of turbine in 1000 h
If the turbocharger is used for the 'Peak shaving' mode with frequent engine start/stop
cycles, the number of successful engine start/stop cycles must be taken into account in ad-
dition to the replacement intervals (in operating hours) for the compressor and the turbine
wheels as well as the bearing check interval, specified on the rating plate.
Further information and specifications regarding inspection and replacement intervals for
the 'Peak shaving' mode use can be found in the chapter Operation and service of the Opera-
tion Manual.
Further data
06 Customer part number
07 Designation for special design
08 Weight of turbocharger in kg
09 Turbocharger type
10 Serial number
11
Year of construction of turbocharger
12
Manufacturing plant
© Copyright 2021 ABB. All rights reserved.