PROOF OF PLAY

This function allows to send messages for the current status of the monitor by self-diagnosis.
Check item
INPUT
Resolution
AUDIO INPUT
Audio signal
Picture Image
AUDIO OUT
TIME
EXPANSION DATA
h
*: This function depends on which option board you are using.
Example:
HDMI1
1920 x 1080
HDMI1
IN1
Normal Picture
Normal Audio
2014/1/1/0h/0m/0s
10h: MEDIA PLAYER is stop
h
NOTE:
For the Proof of Play function, please see the "External_Control.pdf" on the CD-ROM supplied with this monitor.
DVI, DisplayPort1, DisplayPort2, HDMI1, HDMI2, OPTION*, MP, VGA (RGB/YPbPr), VIDEO
ex. (H)1920, (V)1080 , (H)1360, (V)768 or No signal or Invalid signal
IN1, IN2, DisplayPort1, DisplayPort2, HDMI1, HDMI2, OPTION*, MP
Audio in or No Audio in or N/A (IN1, IN2, OPTION (analog)*)
Normal Picture or No Picture
Normal Audio or No Audio
(year)/(month)/(day)/(hour)/(minutes)/(second)
00h: Normal Proof of Play event
01h: Proof of Play event is "last power on time"
10h: MEDIA PLAYER is stop
11h: MEDIA PLAYER is start
12h: MEDIA PLAYER is pause
13h: MEDIA PLAYER error occur
20h: Contents Copy from USB
21h: Contents Copy form network folder
30h: Contents Copy Success
31h: Contents Copy Error (No media)
32h: Contents Copy Error (Connect error)
33h: Contents Copy Error (Out of disk space)
34h: Contents Copy Error (Read/Write error)
40h: Human detected (Human sensor Status)
41h: Human detect cleared (Human Sensor Status)
Message