Page 1
ORDER NO.PHAMOS0503019A1 Microwave Oven NN-P295 NN-H275 / NN-S255 NN-S245 / NN-H264SFR / NN- H264BFR / NN-H264WFR / NN-S254SFR / NN-S254BFR / NN- S254WFR APH(USA) CPH(CANADA) Please file and use this manual together with the service manual for Model NN-S262SF (Order No.SIMMC0203005C1)
Page 2
2005 Panasonic Home Appliances Microwave Oven (Shanghai) Co., Ltd. / All rights reserved. Unauthorized copying and distribution is a violation of law.
Page 11
2.1. Adjustment of primary latch switch, secondary latch switch and short switch. 1. Mount the Primary latch switch, the Secondary latch switch and the short switch to the door hook assembly as shown in ILL. NOTE: No specific individual adjustments during installation of the Primary latch switch, Secondary latch switch or Short switch to the door hook are required.
Page 12
2.2. Measurement of microwave output The output power of the magnetron can be determined by performing IEC standard test procedures. However,due to the complexity of IEC test procedures, it is recommended to test the magnetron using the simple method outlined below. Necessary Equipment: *1 liter beaker *Glass thermometer / *Wrist watch or stopwatch NOTE:...
Page 13
RATED OUTPUT TEMPERATURE RISE 1100W Min. 16.9°F(9.4°C) 1200W Min. 18.5°F(10.3°C) 3. PROCEDURE FOR MEASURING MICROWAVE ENERGY LEAKAGE WARNING Check for radiation leakage after every servicing. Should the leakage be more than 2 mW/cm (1mW/ for Canada) inform PASC, PSC, or PCI immediately.
Page 14
1. Pour 275 ± 15cc (9ozs ± 1/2oz) of 20°C ± 5°C (68° ± 9°F) water in a beaker which is graduated to 600cc, and place in the center of the oven. 2. Set the radiation monitor to 2450MHz and use it following the manufacturer's recommended test procedure to assure correct results.
Page 15
4. SIMPLE WAY OF H.V. INVERTER/MAGNETRON TROUBLESHOUTING Purpose: Simple way (3/23 seconds rule) of identifying whether it’s Magnetron, Inverter, or others. Set-up: The unit under question is connected through the Ammeter as shown below. Procedure:...
Follow the matrix table below to identify the problem source. Note: Do not replace both Inverter board and Magnetron simultaneously and automatically without going through this procedure. Power will: Ammeter reading is: To do: Remedy: Shut off in 23 1. Between 0.5A and 1.0A. Check and repair open Open magnetron wiring seconds after...
Page 17
6.2. PARTS LIST NOTE: 1. When ordering replacement part(s), please use part number(s) shown in this part list. Do not use description of the part. 2. Important safety notice: Components identified by mark have special characteristics important for safety. When replacing any of these components, use only manufacture’s specified parts.
Page 18
Ref. No. Part No. Part Name & Description Pcs/Set Remarks F00205H00AP CAUTION LABEL F00067600CP CAUTION LABEL F00336Z00AP FUSE LABEL F110D6Z00SAP CABINET BODY (U) P295SF APH,H264SFR APH,S254SFR APH F110D6Z00SCP CABINET BODY (U) P295SF CPH F110D6Z00BAP CABINET BODY (U) P295BF,H275SF/ BF,S255BF,S245BF,H264BFR,S254BFR F110D6Z00HAP CABINET BODY (U) P295WF,H275WF,S255WF,S245WF,H264WFR,S254WFR F110D6Z00QAP...
Page 22
Ref. No. Part No. Part Name & Description Pcs/Set Remarks F3018-1200 DOOR KEY A F302A6F00SAP DOOR A (U) P295SF APH/CPH F302A6Z00BAP DOOR A (U) P295BF APH/CPH F302A6Z00HAP DOOR A (U) P295WF APH/CPH F302A6Z20SAP DOOR A (U) H275SF APH/CPH F302A6Z30BAP DOOR A (U) H275BF APH/CPH,S255BF APH/CPH F302A6Z30HAP DOOR A (U) H275WF APH/CPH,S255WF APH/CPH...
Page 42
svcdoc Microwave Oven 1 1. FEATURE CHART 5 2. CONTROL PANEL (APH) 6 3. CONTROL PANEL (CPH) 7 4. OPERATION AND DIGITAL PROGRAMMER CIRCUIT TEST PROCEDURE 8 4.1. To set clock 8 4.2. Time cooking for two stage 9 4.3. Inverter turbo defrost 10 4.4.
svcdoc 12.2.1. Measurement with the outer panel removed. 33 12.2.2. Measurements with a fully assembled oven. 33 12.3. Record keeping and notification after measurement 33 12.4. At least once a year, have the radiation monitor checked for calibration by its manufacturer. 33 13.
Page 44
reserved. Unauthorized copying and distribution is a violation of law.
1. FEATURE CHART MODEL NN-S262 NN-S252 FEATURE Five Stage Cooking Inverter Turbo Defrost Sensor Reheat Sensor Cooking Auto Reheat Inverter Auto Cooking Quick Min Popcorn Digital Clock Timer Child Safety Lock Vent Fan Cooktop Light 2. CONTROL PANEL (APH)
OPERATION SCROLL DISPLAY 1. Plug the power supply BEFORE USE REFER TO cord into wall outlet. OPERATING INSTRUCTIONS 2. Press [Clock] pad. 3. Enter time of day (TOD) by pressing appropriate [Number] pads. 4. Press [Clock] pad. TOD has now been resistered into the digital programmer circuit and will count up...
OPERATION SCROLL DISPLAY 6. Press [Start] pad. 7. When 1st stage cooking time has elapsed. Oven beeps twice and automatically switches to 2nd stage cooking. 8. When 2nd stage Time of day or colon if cooking time has set appears in the display elapsed, oven beeps 5 times and shuts off.
OPERATION SCROLL DISPLAY 1. Press [Beverages] BEVERAGES pad once. PRESS SERVING WEIGHT 2. Press [Serving/Weight 2 CUPS ] pad twice to select 2 cups 3. Press [Start] pad. When cooking time has Time of day or colon if elapsed, Oven beeps 5 set appears in the times and shuts off.
OPERATION SCROLL DISPLAY 1. Press [Auto Reheat] pad twice for two servings. 2. Press [Start] pad.Auto Reheat cycle begins time counts down. 3.When cooking time Time of day or colon if has elapsed, Oven set appears in the beeps 5 times and shuts display.
7. DESCRIPTION OF OPERATING SEQUENCE 7.1. Variable power cooking control High Voltage Inverter Power supply (U) controls output power by the signal from Digital Programmer Circuit (DPC). Power relay stays ON for P4 to P10 and For P1 to P3, both inverter drive signal and power relay to control output power.
The ON/OFF time ratio does not correspond with the percentage of microwave power since approximately 2 seconds are required for heating of magnetron filament. Variable Power Cooking OUTPUT ON-OFF TIME OF POWERSETTING POWER( POWER RELAY B (RY1) APPROX. ON(SEC) OFF(SEC) HIGH 100% MEDIUM-...
When this Auto Control feature is selected and the Start Pad is tapped: 1. The digital programer circuit determines the power level and cooking time to complete cooking and indicates the operating state in the display window. Table shows the corresponding cooking times for respective serving by categories.
Page 59
DANGER OF HIGH VOLTAGE AND HIGH / TEMPERATURE (HOT/LIVE) OF THE INVERTER / POWER SUPPLY (U) This High Voltage Inverter Power Supply circuit supplies very high voltage and very high current for the magnetron tube. Though it is free from danger in ordinary use, extreme care should be taken during repair.
WARNING There is high-voltage present, with high-current capabilities in the circuits of the primary, and secondary windings, choke coil and heat sink of the Inverter. It is extremely dangerous to work on or near these circuits with oven energized. DO NOT measure the voltage in the high voltage circuit including filament voltage of magnetron.
8.6. Confirm after repair 1. After repair or replacement of parts, make sure that the screws of the oven, etc. are neither loose nor missing. / Microwaves might leak if screws are not properly tightened. 2. Make sure that all electrical connections are tight before inserting the plug into the wall outlet.
IMPORTANT NOTICE [NEW H.V.] 1.The following components have potentials above 2000V while the appliance is operated. * Magnetron * High voltage transformer * High voltage diode * High voltage capacitor Pay special attention to these components. 2.When the appliance is operated with the door hinge or magnetron fixed incorrectly, the microwave leakage can reach more than 5mW/cm After repair or exchange, it is very important to...
before handling the DPC. 1. Disconnect all connectors from D.P.C. 2. Remove 2 screws holding escutcheon base and slide the escutcheon base upward slightly. 3. Release CN6 connector's lock of D.P.C by pushing both levels to inside and pull them upward, and remove flat cable of membrane keyboard.
before handling the DPC. (A) Using solder wick or a desoldering tool and 30W soldering iron, carefully remove all solder from the terminal pins of the low voltage transformer and/or power relays. NOTE: Do not use a soldering iron or desoldering tool of more than 30 watts on DPC contacts.
Page 65
7. Remove 1 screw holding orifice on the Inverter bracket. 8. Release 2 tabs to make Inverter bracket flat, and then remove orifice. 9. Release 2 tabs on the Inverter bracket and make flat. 10. Unplug 3 connector on H.V. Inverter (U). 11.
9.5. Door assembly 1. Remove door C from door E by carefully pulling outward starting from upper right hand corner using a flat blade screwdriver. 2. Separate door E from tabs on door A and remove door A. 3. Remove door screen B from door A. 4.
9.6. Stirrer motor 1. Release 1 canoe clip on the cover and then remove the cover. 2. Pull out stirrer. 3. Remove 3 screws which holding exhaust guide A on the oven. 4. Tilt exhaust guide A. 5. Disconnect 2 connectors from stirrer motor. 6.
9.9. Fan motor B (for magnetron cooling) 1. Disconnect 2 lead wires from fan motor B terminals. 2. Remove 4 screws holing fan motor B(U)Assembly. 3. Remove 4 screws which holding fan case installation plate on the fan case C. 4.
1. Disconnect 2 lead wires from turntable motor terminals. 2. Remove 1 screw holding turntable motor. 3. Release from retainer tab by turn spinning certain angle, remove turntable. 10. COMPONENT TEST PROCEDURE CAUTION [NEW. H.V.] 1. High voltage is present at the high voltage terminal of the High Voltage Inverter (U) including aluminum heat sink during any cook cycle.
were connected to Inverter Power Supply (U). 3. Test the continuity of short switch with door opened and closed positions using lowest scale of the ohm meter. / Normal continuity readings should be as follows. 10.3. Magnetron Continuity checks can only indicate an open filament or a shorted magnetron. To diagnose for an open filament or shorted magnetron.
Page 71
DANGER HIGH VOLTAGE Test if failure codes of H97 or H98 appears by doing the following procedure. It is recommended to use an AC line input current Ampere meter for testing. Test1 1. Program DPC. A. Tap Clock B. Tap Timer C.
B. During oven operation, input current is approximately less than 0.4A. INPUT AMPERE FAILURE CODE Unplug CN701 <0.4A Oven stops in 3 seconds after started. If both a and b are OK, the Inverter Power Supply (U) can be determined OK. 11.
circuit and all latch switches again by following the components test procedures. 11.2. Measurement of microwave output The output power of the magnetron can be determined by performing IEC standard test procedures. However,due to the complexity of IEC test procedures, it is recommended to test the magnetron using the simple method outlined below.
TABLE (1L-1min.test) RATED OUTPUT TEMPERATURE RISE 1100W(IEC705-88) Min. 16.9°F(9.4°C) 1200W(IEC705-88) Min. 18.5°F(10.3°C) 12. PROCEDURE FOR MEASURING MICROWAVE ENERGY LEAKAGE WARNING Check for radiation leakage after every servicing. Should the leakage be more than 2 mW/cm (1mW/ for Canada) inform PASC, PSC, or PCI immediately.
1. Pour 275 ± 15cc (9ozs ± 1/2oz) of 20°C ± 5°C (68° ± 9°F) water in a beaker which is graduated to 600cc, and place in the center of the oven. 2. Set the radiation monitor to 2450MHz and use it following the manufacturer's recommended test procedure to assure correct results.
Page 77
CAUTION 1. Check grounding before checking for trouble. 2. Be careful of high voltage circuit. 3. Discharge high voltage capacitor. 4. When checking the continuity of the switches or the high voltage transformer,disconnect one lead wir from these parts and then check continuity with the AC plug removed. To do otherwise may result in a false reading or damage to your meter.
Page 78
SYMPTOM CAUSE CORRECTIONS 5. Timer starts count down but Off-alignment of latch switches Adjust door and latch switches no microwave oscillation. Open or loose connection of high (No heat while oven lamp voltage circuit especially magnetron and fan motor turn on) filament circuit NOTE: Large contact resistance will bring...
13.1. Trouble related to digital programmer circuit SYMPTOM STEP CHECK RESULT CAUSE/CORRECTIO No display when oven is Fuse pattern of DPC Normal STEP 2 first plugged in. Oven is Open (NOTE) Shorted Circuit of dead. ZNR,L.V.T., Oven Lamp etc.Replace D Low voltage Abnormal 0V transformer (LVT)
SYMPTOM STEP CHECK RESULT CAUSE/CORRECTIO Unplug CN702(2 pin) H97/H98 appears in window 1. Latch Switch connector and and ovenstops operation. 2. DPC/Power Relay measure voltage Program High powerfor 1 AC line voltage Step 2 between terminals minute and conduct of 120V following testquickly, unless Unplug CN701(3 pin) H97/H98 appears andoven...
13.3. How to check the semiconductors using an OHM meter 14. EXPLODED VIEW AND PARTS LIST...
Page 82
15. PARTS LIST NOTE: 1. When ordering replacement part(s), please use part number(s) shown in this part list. Do not use description of the part. 2. Important safety notice: Components identified by mark have special characteristics important for safety. When replacing any of these components, use only manufacture’s specified parts.
Page 83
Ref. No. Part No. Part Name & Description Pcs/Set Remarks F00205H00AP CAUTION LABEL F00067600CP CAUTION LABEL F00335H00AP FUSE LABEL F110D5H00SAP CABINET BODY (U) S262SF F110D5H10BAP CABINET BODY (U) S262BF, S252BF F110D5H10HAP CABINET BODY (U) S262WF, S252WF F100D5H00AP BASE PLATE (U) F201A5H00AP OVEN (U) S262SF/BF/WF...
Page 84
Ref. No. Part No. Part Name & Description Pcs/Set Remarks F100T5H00AP BACK PLATE B (U) F400B5H00AP FILTER (U) F400K5H00AP EXHAUST ADAPTER F63175H00SAP GLASS PLATE HOLDER S262SF F63175H10BAP GLASS PLATE HOLDER S262BF, S252BF F63175H10HAP GLASS PLATE HOLDER S262WF, S252WF F64375H00AP GLASS PLATE F41575H00AP FAN INSTALLATION PLATE F42175H00AP...
Ref. No. Part No. Part Name & Description Pcs/Set Remarks F03345H20CP MENU LABEL S252BF/WF CPH 16. DOOR ASSEMBLY Ref. No. Part No. Part Name & Description Pcs/Set Remarks F3018-1200 DOOR KEY A F302A5H00AP DOOR A (U) S262SF F302A5H00BAP DOOR A (U) S262BF, S252BF F302A5H00HAP DOOR A (U) S262WF, S252WF...
Ref. No. Part No. Part Name & Description Pcs/Set Remarks F030A5H00AP LEAD WIRE HARNESS F030A5H00CP LEAD WIRE HARNESS F030E5H00AP H.V.LEAD WIRE F030E5H00CP H.V.LEAD WIRE F03535H00AP LEAD WIRE HARNESS U 18. ESCUTCHEON BASE ASSEMBLY...
Page 88
Ref. No. Part No. Part Name & Description Pcs/Set Remarks F00035H00AP INSTRUCTION MANUAL F00035H00CP INSTRUCTION MANUAL F01025H00AP PACKING CASE PAPER S262SF APH F01025H10BAP PACKING CASE PAPER S262BF APH F01025H10HAP PACKING CASE PAPER S262WF APH F01025H20BAP PACKING CASE PAPER S252BF APH F01025H20HAP PACKING CASE PAPER S252WF APH F01025H00CP...