3-082-317-11(1)
A
A
1
4
AC Adaptor/Charger
3
Operating Instructions
Manual de instrucciones
5
Mode d'emploi
2
使用说明书
Owner's Record
7
The model and serial numbers are located on the bottom of the unit.
Record the serial number in the space provided below.
Refer to these numbers whenever you call upon your Sony dealer regarding
8
WARNING
BATTERY LIFE
this product.
TIME TO CHG
9
NORMAL FULL
h
Model No. AC-VQ50
Serial No.
q;
TM
SERIES
B
AC-VQ50
Sony Corporation © 2003 Printed in Japan
4 4
Mode change
1
WARNING
switch
Selector de mode
To prevent fire or shock hazard, do not
CHARGE lamp
expose the unit to rain or moisture.
Lámpera CHARGE
To install
Para instalar
C
This symbol is intended to alert the user to the presence
of uninsulated "Dangerous voltage" within the
product's enclosure that may be of sufficient magnitude
to constitute a risk of electric shock to persons.
2
This symbol is intended to alert the user to the presence
of important operating and maintenance (servicing)
instructions in the literature accompanying the
1
appliance.
CAUTION
You are cautioned that any changes or modifications not expressly
approved in this manual could void your authority to operate this
equipment.
NOTICE FOR THE CUSTOMERS IN THE USA AND CANADA
4
The Graphical Symbols with Supplemental Marking is located on the
bottom of the unit.
Note:
This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to Part 15 of the FCC Rules. These limits
are designed to provide reasonable protection against harmful interference
in a residential installation. This equipment generates, uses, and can
radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio
communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to
radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
– Reorient or relocate the receiving antenna.
– Increase the separation between the equipment and receiver.
– Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
– Consult the dealer or an experienced radio/TV technician for help.
NOTICE FOR THE CUSTOMERS IN THE UNITED KINGDOM
A moulded plug complying with BS 1363 is fitted to this equipment for
your safety and convenience.
Should the fuse in the plug supplied need to be replaced, a fuse of the
same rating as the supplied one and approved by ASTA or BSI to BS1362
(i.e., marked with
or
mark) must be used.
If the plug supplied with this equipment has a detachable fuse cover, be
sure to attach the fuse cover after you change the fuse. Never use the
plug without the fuse cover. If you should lose the fuse cover, please
contact your nearest Sony service station.
Printed on 100% recycled paper using
VOC (Volatile Organic Compound)-free
vegetable oil based ink.
English
Thank you for purchasing the Sony AC adaptor/charger.
Troubleshooting
Before operating the unit, please read this manual thoroughly and retain it
for future reference.
Video equipmet does not work.
The AC-VQ50 AC adaptor/charger can be used as follows:
• The power plug is disconnected from the wall outlet.
t Insert into the wall outlet.
• To charge a lithium ion type battery pack. Ni-Cd/Ni-MH type batteries
are not rechargeable.
• The connector cable is not properly connected.
t Connect properly.
The following functions are available with the "InfoLITHIUM" battery
• The mode change switch is set to CHARGE.
pack:
– Quickly charging
t Set the mode change switch to VCR/CAMERA.
6
– Remaining charge time display
The battery is not charged.
• To enable the power supply to the video equipment with the house
• The mode change switch is set to VCR/CAMERA.
current, connection cords are included with this unit.
t Set the mode change switch to CHARGE.
Power immediately turns off even though there is sufficient remaining
What is the "InfoLITHIUM" ?
battery power, or the displayed remaining time differs from the actual
The "InfoLITHIUM" is a lithium ion battery pack which can exchange data
time.
with compatible electronic equipment about its battery consumption. Sony
• Fully charge again.
recommends that you use the "InfoLITHIUM" battery pack (M series) with
t The remaining battery power will be correctly displayed.
electronic equipment having the
mark.
The display is not switched.
"InfoLITHIUM" is a trademark of Sony Corporation.
t Read "About the remaining battery time".
The CHARGE lamp blinks, and "WARNING" is displayed in the display
qa
window.
WARNING
qs
t Check through the following chart.
VCR/CAMERA
To prevent fire or shock hazard, do not expose the unit to rain or moisture.
Remove the battery pack from this unit, then install the same battery
qd
pack again.
To avoid electrical shock, do not open the cabinet.
Refer servicing to qualified personnel only.
m
AC power cord must be changed only at the qualified service shop.
If the CHARGE lamp flashes
qf
again:
For the customers in Canada
Install another battery pack.
CAUTION
TO PREVENT ELECTRIC SHOCK, MATCH WIDE BLADE OF PLUG TO
WIDE SLOT, FULLY INSERT.
2
If the CHARGE lamp flashes
again:
Notes on Use
The problem is with this unit.
About the AC power cord plug
3
The AC-VQ50 comes in two models, differentiated by the shape of the AC
power cord plug.
Model
Shape of the plug
Please contact your nearest Sony dealer in connection with the product
with the problem.
Model for USA/Canada
Polarized
Model for other countries/regions
Non polarized
AC power cord
Cable de alimentación de ca
Specifications
The model for USA and Canada: One blade of the plug is wider than the
other for the purpose of safety and will fit into the wall outlet only one way.
Input rating
If you are unable to insert the plug fully into the outlet, contact your dealer.
To remove
About the remaining battery time
Output rating
Para extraer
While charging the battery pack, this unit will show the remaining battery
Operating temperature
time with your video equipment, etc. on the following conditions.
Storage temperature
• Using the "InfoLITHIUM" battery pack
Dimensions
• Using the electronic equipment having the
mark
Make sure that you use the battery pack having the
mark.
Mass
Consult the operating instructions supplied with your video equipment if it
Supplied accessories
is applied to "InfoLITHIUM".
If you use this battery pack with electronic equipment not having the
Design and specifications are subject to change without notice.
mark, the remaining battery capacity will not be indicated in minutes.*
Use a commercially available AC plug adaptor, if necessary, depending on
*The indication may not be accurate depending on the condition and environment
the design of the wall outlet.
which the equipment is used under
Warranty for Recorded Content
Contents of the recording cannot be compensated if recording or playback
is not made due to a malfunction of the battery pack, AC adaptor, AC
adaptor/charger, etc.
3 3
We cannot provide compensation for image
Do not connect the battery charger to a voltage adaptor (travel
converter) for overseas travel. This may result in overheating or other
content
malfunction.
We cannot provide compensation for recorded content such as images and
sound, if images are not recorded or played back due to a malfunction in
the AC adapter/charger, etc.
Identifying the parts
Charging
Use only a lithium ion type battery pack. This unit cannot be used to
1 Terminal shutter
charge a Ni-Cd/Ni-MH type battery pack.
2 DC OUT connector
• Attach the battery pack firmly.
3 CHARGE lamp
• Charge the battery pack on a flat surface without vibration.
4 Mode change switch
5 DISPLAY change button
Charging temperature
6 Display window
• To provide maximum battery efficiency, the recommended
temperature range when charging is +10°C to +30°C (+50°F to +86°F).
Display window
• This unit complies with quick charging, but charging outside the
7 "InfoLITHIUM" indicator
recommended temperature range will lead to longer charging times in
8 WARNING indicator
order to protect the battery pack. Once the charging time has been
9 TIME TO CHG (charge) indicator
extended, it will not return to quick charging even if the temperature is
q; Time indicator
brought within the recommended temperature range. Reattach the
qa BATTERY LIFE (battery remaining time) indicator
5
battery and then recharge it.
qs VCR/CAMERA indicator
Others
qd Full charge indicator
qf Remaining battery indicator
• The nameplate indicating operating voltage, power consumption, etc. is
located on the bottom.
• The negligible amount of electric current will flow into the AC adaptor/
To Charge the Battery Pack
charger as long as the AC adaptor/charger is plugged into the wall outlet.
• Unplug the unit from the wall outlet if it will not be used for extended
period of time. To disconnect the cord, pull it out by the plug. Never pull
1 Set the mode change switch to CHARGE.
the cord itself.
• Do not operate the unit with a damaged cord or if it has been dropped or
2 Connect the power cord to this unit.
damaged.
• Use this unit near to a wall outlet. This is to ensure that the power plug
3 Connect the power cord to a wall outlet.
can be immediately unplugged from the wall outlet to turn the power off
if some abnormality occurs during use.
4 Install the battery pack.
• Be sure that nothing metallic comes into contact with the metal parts of
the unit or connecting plate. If it does, a short may occur and the unit
may be damaged.
• Always keep the metal contacts clean.
• Do not disassemble or convert the unit.
• Do not apply mechanical shock or drop the unit.
• While the unit is in use, it gets warm. But this is normal.
• Keep the unit away from AM receivers, because it will disturb AM
reception.
• Do not place the unit in a location where it is:
— Extremely hot or cold
— Dusty or dirty
— Very humid
— Vibrating
• Placing this unit in locations near heating apparatus may cause this unit
to deform or malfunction.
To Install the battery pack
If any difficulty should arise, unplug the unit and contact your nearest Sony
dealer.
To remove the battery pack
Slide it in the direction opposite to the operation when you attach it to this
unit, and lift the battery pack above.
Notes
• Do not lift the unit by gripping the battery pack.
• Do not apply shock to the terminal shutter. When you install the battery
pack, be sure not to strike it to the terminal shutter.
• Be careful not to pinch your fingers during attachment and removal of the
battery pack.
Charging time
The following table shows the charging time for the battery pack which is
discharged completely.
Quick charge
NP-FM70/
NP-QM71/
battery pack NP-FM30 NP-FM50
QM70
QM71D
full charging
100
105
150
175
time
normal charging
(40)
(45)
(90)
(115)
time
• Approximate minutes at +25°C (+77°F) to charge an empty battery pack
used with this unit.
• Approximate minutes to charge an empty battery pack fully (Full charge).
• Numbers in parentheses indicate the time when you charge normally
(Normal charge).
If the CHARGE lamp lights and
• To ascertain the battery life, refer to the instruction mamual of the video
does not flash again:
equipment which you use.
If the CHARGE lamp goes out
• The charging time may differ depending on the condition of the battery
because the charging time has
pack or the temperature of the environment.
passed, there is no problem.
To use the battery pack quickly
You can remove the battery pack from this unit to use even though the
charging is not completed yet. However, the time that the battery pack can
If the CHARGE lamp lights and
does not flash again:
be used differs depending on the charging time.
If the CHARGE lamp goes out
Notes
because the charging time has
• When the mode change switch is set to VCR/CAMERA during charging,
passed, the problem is with the
charging stops.
battery pack first installed.
• If the CHARGE lamp does not light or flash, check that the battery pack is
correctly attached to the AC adaptor/charger. If it is not attached it will
not be charged.
To Check Charging
While charging, you can check the charging time on the display. After
starting charging in a minute, BATTERY LIFE lights up on the display.
The displayed remaining time is the approximate time when taking
photographs via the viewfinder. The remaining time is shorter when the
100 - 240 V AC, 50/60 Hz
LCD display is used.
25 W, 0.40 A (VCR), 0.35 A (BATT)
The remaining battery time may not be displayed depending on using
DC OUT: 8.4 V, 2.0 A (VCR)
conditions and circumstances of your video camera recorder and of the
8.4 V, 1.4 A (BATT)
battery. See "About the remaining battery time" for more details.
0°C to +40°C (+32°F to +104°F)
–20°C to +60°C (–4°F to +140°F)
Press DISPLAY while charging is underway.
Approx. 88 × 47 × 80 mm (w/h/d)
Each time you press DISPLAY, the display changes as follows.
× 1
× 3
(3
1
/
7
/
1
/
inches)
2
8
4
Approx. 180 g (6.4oz)
The remaining battery time
Connecting cord DK-215 (1),
BATTERY LIFE
when the battery pack being
charged is attached to your
AC power cord (1)
m
"InfoLITHIUM" electronic
equipment
The time is not displayed when the
remaining battery time is less than 5
DISPLAY
Wall outlet
minutes.
The remaining time until normal
AC-VQ50
charge is completed
TIME TO CHG
The normal charge time is not
NORMAL
m
displayed after the normal charge is
AC plug adaptor
complete.
DISPLAY
The remaining time until full
charge is completed
TIME TO CHG
The full charge time is not displayed
FULL
h
m
after the full charge is complete.
DISPLAY
See illustration A.
Notes
• To display the remaining battery time of a new battery, attach it to your
video camera recorder and use it for about 20 seconds. Then, charge the
battery with this unit and start charging, and the remaining battery time
will be displayed.
• The time display shows the approximate time when charging at +25°C.
The time display may differ from the actual charging time depending on
using conditions and circumstances.
• The time display may show "– – – –" in the following cases. However, the
unit is not malfunctioning.
– The remaining battery time is less than 5 minutes.
– There is a difference between the displayed time and actual charging
time. Even if this happens, continue charging.
• Full charge requires about 1 hour after normal charge is completed. If you
remove the battery pack between normal charge and full charge, the
charging time may not be displayed properly in the next charging.
• When a battery that has not been used for a long time is charged, the
displayed remaining time and full charge time sometimes differ from the
actual times. This is not a malfunction. If this happens, charge the battery
pack until it is fully charged. The correct times can be displayed.
• When you attach a fully charged battery pack to this unit, "TIME TO
See illustration B.
CHG FULL 1h" may appear on the display. However, this is not a
malfunction.
• You may wait for a while after pressing DISPLAY until the display shows
the time indication.
The beep sounds and the display window lights up.
To Operate Video Equipment
Charging begins. When the remaining battery indicator becomes
and the CHARGE lamp lights up, normal charge is completed. For full
The AC adaptor/charger can supply power from a wall outlet.
charge, which allows you to use the battery slightly longer than "normal
For details of the connection, refer to the instruction manual of the video
charge", leave the battery pack attached until the CHARGE lamp goes
equipment.
out.
Remove the battery pack when required. It can be used even if the
1 Set the mode change switch to VCR/CAMERA.
charging is not completed.
2 Connect the power cord to this unit.
Remaining battery indicator
3 Connect the power cord to a wall outlet.
Normal charge
Full charge
4 Connect the connecting cord to DC OUT connector of this unit.
5 Open the DC IN terminal cover of the video equipment, connect
the connecting cord to the DC IN terminal.
For details of the direction of the connecting cord, refer to the instruction
manual of the video equipment.
Notes
1 Place the battery pack on this unit with the b b b b b mark facing the
• If you set the mode change switch to CHARGE while operating the video
terminal shutter.
equipment, the power supply to the video equipment stops.
2 Slide the battery pack in the direction of the arrow.
• You cannot charge the battery pack attached to AC adaptor/charger
Press the battery pack until the terminal shutter enters completely
while operating the power to the video equipment.
into this unit.
• Keep AC adaptor/charger away from the video equipment if the picture
is disturbed.
Español
Gracias por adquirir el adaptador/cargador de ca de Sony.
• El cable conector no está no está adecuadamente conectado.
t Conéctelo adecuadamente.
Antes de utilizar la unidad, lea detenidamente este manual, y consérvelo
• El selector de modo está en CHARGE.
para futuras referencias.
t Póngalo en VCR/CAMERA.
El adaptador/cargador de ca AC-VQ50 podrá utilizarse de la forma
La batería no se carga.
siguiente:
• El selector de modo está en VCR/CAMERA.
• Para cargar una batería de tipo iones de litio. Las pilas de tipo Ni-Cd/
t Póngalo en CHARGE.
Ni-MH no podrán recargarse.
La alimentación se desconecta inmediatamente aunque queda
Cuando utilice una batería "InfoLITHIUM", estarán disponibles las
suficiente energía en la batería, o el tiempo restante visualizado difiere
funciones siguientes:
del real.
– Carga rápida
– Visualización del tiempo de carga restante
• Vuelva a cargar completamente la batería.
t La energía restante de la batería se visualizará correctamente.
• Con esta unidad se incluyen cables de conexión para poder alimentar
equipos de vídeo con la corriente de la red.
La visualización no cambia.
t Consulte "Sobre el tiempo restante de la batería".
Descripción del paquete de batería "InfoLITHIUM"
La lámpara CHARGE parpadea, y en el visualizador se indica
"InfoLITHIUM" es una batería de iones de litio que puede intercambiar
"WARNING".
información con equipos electrónicos compatibles sobre su consumo de
NP-FM91/
t Compruebe el organigrama sigiente.
NP-FM90
batería. Sony recomienda utilizar la batería "InfoLITHIUM" (serie M) con
QM91/QM91D
equipos electrónicos que posean la marca
.
Retire la batería de esta unidad y, a continuación, vuelva a instalar la
195
205
misma batería.
"InfoLITHIUM" es una marca comercial de Sony Corporation.
(135)
(145)
ADVERTENCIA
Si la lámpara CHARGE
vuelve a parpadear:
Para evitar incendios o el riesgo de electrocución, no exponga la unidad a la
Instale otra batería.
lluvia ni a la humedad.
Para evitar descargas eléctricas, no abra la unidad.
En caso de avería, solicite los servicios de personal cualificado solamente.
El cable de alimentación de ca solamente deberá ser cambiado en un
Si la lámpara CHARGE
taller de reparaciones cualificado.
vuelve a parpadear:
El problema reside en esta
Notas sobre la utilización
unidad.
Sobre el enchufe del cable de alimentación de
ca
Existen dos modelos de AC-VQ50, que se diferencian por la forma del
Póngase en contacto con su proveedor Sony más cercano en relación con
enchufe del cable de alimentación de ca
el producto afectado.
Modelo
Forma del enchufe
Modelo para EE.UU./Canadá
Polarizado
Especificaciones
Modelo para otros países/regiones
No polarizado
Entrada
Modelo para EE.UU. y Canadá: Por motivos de seguridad, una cuchilla del
Salida
enchufe es más ancha que la otra, y solamente encajará en el tomacorriente
de una sola forma. Si no puede insertar firmemente el enchufe en el
Temperatura de funcionamiento
tomacorriente, póngase en contacto con su proveedor.
Sobre el tiempo restante de la batería
Temperatura de almacenamiento
Durante la carga de la batería, esta unidad mostrará el tiempo restante de la
Dimensiones
batería con su equipo de vídeo, etc., en las condiciones siguientes.
Masa
• Utilización de una batería "InfoLITHIUM"
Accesorios suministrados
• Empleo del equipo electrónico que posea la marca
Cerciórese de utilizar una batería que posea la marca
.
El diseño y las especificaciones están sujetos a cambio sin previo aviso.
Si su equipo de vídeo puede utilizar baterías "InfoLITHIUM", consulte el
manual de instrucciones del mismo.
No conecte el cargador de baterías a un adaptador de tensión
(convertidor para viajes) para ultramar. Esto podría causar el
Si utiliza esta batería con un equipo electrónico que no posea la marca
,
recalentamiento u otros problemas.
la capacidad de batería restante no se indicará en minutos.*
*La indicación puede no ser precisa en función de la condición y el entorno en los que
se emplee el equipo
Identificación de partes
Garantía del contenido grabado
El contenido de la grabación no podrá compensarse si la grabación o la
reproducción no se realiza debido a un mal funcionamiento de la batería, el
1 Obturador del terminal
adaptador de ca el adaptador cargador de ca , etc.
2 Conector DC OUT
No habrá ninguna compensación por el
3 Lámpara CHARGE
4 Selector de modo
contenido de las imágenes
5 Botón DISPLAY change
Nosotros no ofreceremos ninguna compensación por el contenido grabado,
6 Visualizador
como imágenes y sonido, si no se graban o reproducen debido al mal
Visualizador
funcionamiento del adaptador de ca/cargador, etc.
7 Indicador "InfoLITHIUM"
Carga
8 Indicador WARNING
Utilice solamente una batería de tipo de iones de litio. Esta unidad no
9 Indicador TIME TO CHG (carga)
podrá utilizarse para cargar una batería de tipo Ni-Cd/Ni-MH.
q; Indicador de tiempo
• Fije firmemente la batería.
qa Indicador BATTERY LIFE (tiempo restante de la batería)
• Cargue la batería sobre una superficie plana exenta de vibraciones.
qs Indicador VCR/CAMERA
qd Indicador de carga completa
Temperatura de carga
qf Indicador de batería restante
• La gama de temperaturas para la carga recomendada para obtener el
máximo rendimiento de la batería es de +10°C a +30°C
• Esta unidad es compatible con la carga rápida, pero la carga fuera de
Para cargar la batería
la gama de temperaturas recomendada aumentará el tiempo de carga
para proteger la batería. Después de haberse sobrepasado el tiempo de
carga, ésta no volverá a la carga rápida aunque la temperatura entre
1 Ponga el selector de modo en CHARGE.
dentro de la gama de temperaturas recomendada. Reinstale la batería
y después cárguela.
2 Conecte el cable de alimentación a esta unidad.
3 Conecte el cable de alimentación a un tomacorriente.
Otros
Sonará un pitido y se encenderá el visualizador.
• La placa de características en la que se indica la tensión de alimentación,
4 Instale la batería.
el consumo, etc., se encuentra en la parte inferior.
• Mientras el adaptador/cargador de ca esté enchufado en un
Se iniciará la carga. Cuando el indicador de batería restante pase a ser
, y se encienda la lámpara CHARGE, habrá finalizado la carga
tomacorriente, a través del adaptador/cargador circulará cierta cantidad
normal. Para realizar la carga completa, que le permitirá utilizar la
de corriente.
• Cuando no vaya a utilizar la unidad durante mucho tiempo, desenchúfela
batería algo más que con la "carga normal", deje la batería instalada en
la unidad hasta que se apague la lámpara CHARGE.
del tomacorriente. Para desconectar el cable de alimentación, tire del
enchufe. No tire nunca del propio cable.
Extraiga la batería cuando lo requiera. Podrá utilizarse incluso aunque
no se haya completado la carga.
• No utilice la unidad con un cable dañado, cuando se haya caído, ni
cuando esté dañada.
Indicador de batería restante
• Utilice esta unidad cerca de un tomacorriente de la red. Esto es para
poder desconectar inmediatamente el enchufe de alimentación del
Carga normal
tomacorriente de la red, a fin de desconectar la alimentación, en caso de
producirse cualquier anormalidad durante la utilización.
• Cerciórese de que ningún objeto metálico entre en contacto con las partes
metálicas de la unidad ni con la placa conectora. En caso contrario podría
See illustration C.
producirse un cortocircuito y la unidad se dañaría.
Para instalar la batería
• Mantenga siempre limpios los contactos metálicos.
• No desarme ni modifique la unidad.
1 Coloque la batería en esta unidad con la marca b b b b b encarada hacia
• No golpee ni deje caer la unidad.
el obturador de terminales.
• Cuando utilice la unidad, se calentará. Sin embargo, esto es normal.
2 Deslice la batería en el sentido de la flecha.
• Mantenga la unidad alejada de receptores de AM, porque podría
Presione la batería hasta que el obturador de terminales
perturbarse la recepción de AM.
completamente en esta unidad.
• No coloque la unidad en un lugar:
Para extraer la batería
— Extremadamente cálido o frío
— Polvoriento o sucio
Levántela y deslícela en el sentido opuesto al de instalación en esta unidad.
— Muy húmedo
— Sometido a vibraciones
Notas
• Si coloca la unidad en lugares sometidos a aparatos de calefacción, es
• No levante la unidad sujetándola por la batería.
posible que se deforme o funcione mal.
• No golpee el obturador de terminales. Cuando instale la batería, tenga
cuidado de no golpearla contra el obturador de terminales.
Si tiene alguna dificultad, desenchufe la unidad y póngase en contacto con
• Tenga cuidado de no pillarse los dedos cuando instale o extraiga la
su proveedor Sony.
batería.
Solución de problemas
El equipo de vídeo no funciona.
• El enchufe de alimentación está desconectado del tomacorriente de la red.
t Insértelo en el tomacorriente de la red.
Tiempo de carga
En la tabla siguiente se muestra el tiempo de carga para una batería
completamente descargada.
Carga rápida
NP-FM70/
NP-QM71/
NP-FM91/
batería
NP-FM30 NP-FM50
NP-FM90
QM70
QM71D
QM91/QM91D
Tiempo de
100
105
150
175
195
carga completa
Tiempo de carga
(40)
(45)
(90)
(115)
(135)
(145)
normal
• Minutos aproximados a +25°C para cargar una batería vacía utilizando
esta unidad.
• Minutos aproximados para cargar completamente una batería (carga
completa).
• Los números entre paréntesis indican el tiempo para la carga normal
(Carga normal).
• Para asegurarse de la duración útil de la batería, consulte el manual de
instrucciones del equipo de vídeo con el que vaya a utilizarla.
• El tiempo de carga puede diferir dependiendo de la batería o del medio
ambiente.
Si la lámpara CHARGE se ilumina y
Para utilizar rápidamente la batería
no vuelve a parpadear:
Usted podrá extraer la batería de esta unidad incluso aunque no se haya
Si la lámpara CHARGE se apaga
cargado completamente. Sin embargo, el tiempo que podrá utilizar la
porque ha transcurrido el tiempo
batería dependerá del tiempo que la haya cargado.
de carga, no hay problema.
Notas
• Si pone el selector de modo en VCR/CAMERA durante la carga, ésta se parará.
Si la lámpara CHARGE se ilumina y
• Si la lámpara CHARGE no se enciende o parpadea, compruebe si la
batería está correctamente instalada en el adaptador/cargador de ca
no vuelve a parpadear:
Si la lámpara CHARGE se apaga
Si no está bien instalada, no se cargará.
porque ha transcurrido el tiempo de
Para comprobar la carga
carga, el problema reside en la batería
instalada en primer lugar.
Durante la carga podrá comprobar el tiempo de carga en el visualizador.
Un minuto después de haber iniciado la carga, en el visualizador se
encenderá BATTERY LIFE.
El tiempo restante visualizado será el aproximado cuando tome fotografías a
través del visor. El tiempo será más corto cuando utilice la pantalla de
cristal líquido.
El tiempo restante de la batería puede no aparecer en función de las
condiciones y circunstancias de uso de la videocámara y de la batería.
Consulte "Sobre el tiempo restante de la batería" para obtener más
ca 100 - 240 V , 50/60 Hz
información.
25 W 0,40 A (VCR) 0,35 A (BATT)
Presione DISPLAY durante la carga.
DC OUT: cc 8,4 V 2,0 A (VCR)
Cada vez que presione DISPLAY, la visualización cambiará de la forma
cc 8,4 V 1,4 A (BATT)
siguiente.
0°C a +40°C
Tiempo restante de la batería
BATTERY LIFE
cuando la batería en proceso de
–20°C a +60°C
carga está fijada al equipo
Aprox. 88 × 47 × 80 mm (an/al/prf)
m
electrónico "InfoLITHIUM"
Aprox. 180 g
El tiempo no se visualizará cuando el
Cable de conexión DK-215 (1),
tiempo restante de la batería sea
Cable de alimentación de ca (1)
DISPLAY
inferior a 5 min
Tiempo restante hasta que
finalice la carga normal
TIME TO CHG
El tiempo de carga normal no se
NORMAL
m
visualizará después de haber
finalizado la carga normal.
DISPLAY
Tiempo restante hasta que
finalice la carga completa
Consulte la ilustración A.
TIME TO CHG
El tiempo de carga completa no se
FULL
h
m
visualizará después de haber
finalizado la carga completa.
DISPLAY
Notas
• Para visualizar el tiempo restante de una batería nueva, fíjela a la
videocámara y utilícela durante unos 20 s Después, cargue la batería con
esta unidad, y se visualizará el tiempo restate de la batería.
• La visualización del tiempo mostrará el tiempo aproximado cuando la carga
se realice a +25ºC La visualización del tiempo puede diferir del tiempo de
carga real dependiendo de las condiciones y circunstancias de utilización.
• La visualización de tiempo puede mostrar "– – – –" en los casos siguientes.
Sin embargo, esto no significa que la unidad está funcionando mal.
– El tiempo de batería restante es inferior a 5 min
– Existe una diferencia entre el tiempo visualizado y el tiempo de carga
real. Aunque suceda esto, continúe cargando.
• La carga completa requerirá aproximadamente 1 h después de haber
finalizado la carga normal. Si extrae la batería entre la carga normal y la
carga completa, es posible que el tiempo de carga no se visualice
adecuadamente en la próxima carga.
Consulte la ilustración B.
• Cuando cargue una batería que no haya utilizado durante mucho tiempo,
el tiempo restante visualizado y el tiempo de carga completa pueden
diferir a veces de los tiempos reales. Esto no significa mal
funcionamiento. Cuando suceda esto, cargue completamente la batería.
Se visualizarán los tiempos correctos.
• Cuando instale una batería completamente cargada en esta unidad, en el
visualizador puede aparecer "TIME TO CHG FULL 1h". Sin embargo,
esto no significa que la unidad está funcionando mal.
• Es posible que tenga que esperar cierto tiempo hasta que el visualizador
muestre la indicación de tiempo después de haber presionado DISPLAY.
Para utilizar el equipo de vídeo
Consulte la ilustración C.
El adaptador de ca/cargador podrá suministrar alimentación de un
tomacorriente.
Con respecto a los detalles sobre la conexión, consulte el manual de
Carga completa
instrucciones del equipo de vídeo.
1 Ponga el selector de modo en VCR/CAMERA.
2 Conecte el cable de alimentación a esta unidad.
3 Conecte el cable de alimentación a un tomacorriente.
4 Conecte el cable conector al conector DC OUT de esta unidad.
5 Abra la cubierta del termina DC IN del equipo de vídeo y
conecte el cable conector al terminal DC IN.
Con respecto a los detalles sobre el sentido del cable conector, consulte el
manual de instrucciones del equipo de vídeo.
Notas
• Si pone el selector de modo en CHARGE mientras esté utilizando el
equipo de vídeo, la fuente de alimentación de éste se cortará.
• Usted no podrá cargar la batería instalada en esta unidad mientras esté
utilizando el equipo de vídeo.
• Si las imágenes se ven con perturbaciones, mantenga esta unidad alejada
del equipo de vídeo.
205