hit counter script

B+B Sensors LogBox-RHT-LCD Operating Manual

Temperature and humidity data logger

Advertisement

Quick Links

Operating Manual
LogBox-RHT-LCD
Temperature and Humidity Data Logger
0568 0038-01
V1.1x F

Advertisement

Table of Contents
loading

Summary of Contents for B+B Sensors LogBox-RHT-LCD

  • Page 1 Operating Manual LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 V1.1x F...
  • Page 2: Table Of Contents

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 ONTENTS Foreword ........................................... 1 GENERAL ADVICE ......................................1 2.1. Labels ........................................1 Warning Advice ......................................1 Security Advices ......................................2 Introduction ........................................2 Identification ........................................ 2 Technical Specifications ....................................3 Measurement Accuracies .................................... 3 Operation ..........................................
  • Page 3 LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 9.3.3 Start Logging Field ..................................13 9.3.4 Stop Loggings ....................................13 9.3.5 Channels Field ....................................14 Data Download and Visualization ................................14 9.4.1 Graph window ....................................15 9.4.2 General information table ................................15 9.4.3...
  • Page 4: Foreword

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 OREWORD Dear customer, We thank you for having purchased the LogBox RHT-LCD Temperature and Humidity Data Logger and are very glad that you decided in favour of a product of B+B Thermo-Technik GmbH. We hope this product will fully satisfy you and will assist you effectively in your work.
  • Page 5: Security Advices

    NTRODUCTION The LogBox-RHT-LCD is an electronic logger of temperature and relative humidity. There are sensors that measure such data and values (data) obtained are displayed in an LCD screen and stored in an electronic memory. Data can be later viewed and analyzed on a PC where they can be opened in tabular and graphical forms.
  • Page 6: Technical Specifications

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 Channel Indicator: Indicates the channel selected. Battery Indicator: The battery symbol is shown when the battery voltage is low. MIN / MAX values indicator: Minimum and maximum value of each channel during readings.
  • Page 7: Operation

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 Figure 3 Mesurement Accuracies PERATION It is only possible to operate the device after the NXperience or LogChart II software are installed to a PC, according to the steps described in the corresponding chapters of this manual.
  • Page 8: Min / Max Indication

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 5.1.3 Min / Max Indication It indicates the minimum and maximum value during the acquisitions. The Channel for which the values are just displayed is indicated on the screen on the left side as CH1 or CH2 Figure 7 Min Max Indication Screen 5.1.4...
  • Page 9: Irlink3 Interface Installation

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 For saving battery energy it has to set the longest interval possible between acquisitions, as well as for display updating. Examples: Ex. 1: Acquisitions interval equal to 10 minutes and DISP screen in LO6 mode. In this case register remains sleeping and activates only in every 10 minutes to read the sensor, update the display and save the acquisitions to the memory.
  • Page 10: Communicating With Logger

    Figure 10 Driver Installation 7.2 Communicating with Logger You can communicatewith the LogBox-RHT-LCD using NXperience or LogChart II software. To do so, however, the Communication Interface must be connected to the computer. The interface must be constantly directed towards the front part of the logger (communication window) at a maximum distance of 50 cm, as shown in Fig 11.
  • Page 11: Nxperience Software

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 8 NX PERIENCE OFTWARE 8.1 Installation NXperience software allows you to explore all the features of the device by communicating through its USB interface. It is also a complete tool to perform the analysis of the data logged.
  • Page 12: Channels Parameters

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 8.2.2 Channels Parameters Figure 14 Channel parameters Tag: Allows you to set a name, which will be used as channel identification during a download, for the channel. The field allows up to •...
  • Page 13: Finalization

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 Figure 15 Log register START MODE Immediate Start: Start as soon as set up is ready and sent (OK) to the device. • • Date/Time: Logs start at predefined date and time.
  • Page 14: Downloading And Data Visualization

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 LOG CONTROL Start or Resume: Allows you to start or resume logs that have been interrupted by the Pause command, without discarding logs that • are in the device's memory, using the configured parameters.
  • Page 15: Logchart Ii Software

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 II S HART OFTWARE 9.1 Installing LogChart II The LogChart II is the software provided with the logger to allow for configuration and data collection. To install the LogChart II, execute the LC_II_Setup.exe program available on our website.
  • Page 16: General Information Field

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 Figure 23 Acquisition Parameters 9.3.1 General Information Field General information on the top of the screen informs the model, serial number, logger current date/time, PC date/time, firmware version (logger model version), memory capacity and used memory. This information is displayed in the upper part of the LogChart-II configuration screen.
  • Page 17: Channels Field

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 9.3.5 Channels Field By selecting the “Channels” option, the user is able to choose the individual settings for each input channel, as Fig. 7 shows Figure 24 Channels Configuration The Parameters are: Tag: Defines a name (up to 8 characters) for identifying the variable to be measured.
  • Page 18: Graph Window

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 9.4.1 Graph window The Graph is a convenient tool for analysis. It enables the logger acquisitions to be read in the form of a “values x time” graph. As one moves the mouse in the chart area, the time, and the value of the records of each channel are shown in the field located in the bottom of the window.
  • Page 19: Acquisitions Table Window

    LogBox-RHT-LCD Temperature and Humidity Data Logger 0568 0038-01 9.4.3 Acquisitions Table Window Data acquired by one or both input channels (user-defined) are displayed in engineering units in a table format. The table displays register number, date/time and the record values 9.4.4...

Table of Contents