Summary of Contents for Label NEXT 75

  • Page 1 NEXT 75 Automation for interior swing doors TRANSLATION OF THE ORIGINAL INSTRUCTIONS NEXT 75_Eng_Rel.1.0_01/2019 - CD0750En-MU...
  • Page 2 RECOMMENDATIONS THIS INSTRUCTION MANUAL IS INTENDED FOR THE FINAL USER OF A LABEL AUTOMATIC SWINGING DOOR SYSTEM; IT IS UNDERSTOOD THAT INSTALLATION AND TESTING MUST HAVE BEEN CARRIED OUT BY SPECIALISED PERSONNEL. GENERAL SAFETY WARNINGS BEFORE COMMISSIONING THE AUTOMATIC DOOR, PLEASE CAREFULLY READ THIS...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS: 1) INDICATIVE SYSTEM DESCRIPTION 2) TECHNICAL DATA 3) AUTOMATIC DOOR OPERATION 3.1) NORMAL DOOR OPERATION 3.2) DOOR OPERATION IN NIGHT LOCK MODE 3.3) DISABLED PEOPLE OPERATING MODE 4) PROGRAM SELECTORS 4.1) MANUAL PROGRAM SELECTOR 4.2) EV-MSEL MECHANICAL KEY SELECTOR 4.3) ET-DSEL DIGITAL PROGRAM SELECTOR 4.4) T-NFC DIGITAL PROGRAM SELECTOR 4.5) ET-DSEL SELECTOR GENERAL PROGRAMMING MENU...
  • Page 4: Indicative System Description

    EXTERNAL RADAR INTERNAL RADAR OPENING COMMAND PROGRAM SELECTOR SAFETY SENSOR FOR CLOSING SAFETY SENSOR FOR OPENING NEXT 75 AUTOMATION ELECTRIC LOCK FLOOR STOP 2) TECHNICAL DATA AUTOMATION MODEL NEXT 75 POWER SUPPLY 115/230~ , 50/60Hz...
  • Page 5: Automatic Door Operation

    3) AUTOMATIC DOOR OPERATION WARNING!! Always contact the service technician before commissioning the door, to learn how the automation works. Switch on the power supply by means of the system switch. The automation electronic control unit beeps shortly to indicate that the automatic door is powered. The first opening command starts a calibration cycle during which the door opening speed is very low until the end of the stroke, to find the stop point;...
  • Page 6: Program Selectors

    The program selector allows the user of the door to select the operating mode. Depending on the preference, it is possible to use the manual selector incorporated in the side panel of the automation NEXT 75, the mechanical key selector EV-MSEL, or the digital programmer ET-DSEL or T-NFC.
  • Page 7: Dsel Digital Program Selector

    4.3) ET-DSEL DIGITAL PROGRAM SELECTOR Pressing once the button select the automatic door operating mode. Whenever the button is pressed, you switch from a work program to the next. The operating programs which can be selected using the button are described below. Automatic bidirectional program The door automatically opens when each opening control activates.
  • Page 8: T-Nfc Digital Program Selector

    4.4) T-NFC DIGITAL PROGRAM SELECTOR DAILY USE The selector T-NFC allows to select 6 different types of programs for everyday use: AUTO: ENTRY: The door opens and closes automatically The door opens and closes automatically in both flow directions with all sensors only in entry direction: active.
  • Page 9: Dsel Selector General Programming Menu

    4.5) ET-DSEL SELECTOR GENERAL PROGRAMMING MENU The user can enter the general programming menu when he wishes to select the desired language for the texts that appear on the display, or when he wishes to enable a password to prevent any unauthorised access to the ET-DSEL digital programmer. DIAGRAM 1 SECTION RESERVED FOR SECTION RESERVED FOR...
  • Page 10: Dsel Selector User Password Management

    4.6) ET-DSEL SELECTOR USER PASSWORD MANAGEMENT To prevent the door work program from being modified, you can enter a password every time the ET-DSEL programmer is used. To enable the password perform the operations listed below: Press and hold the SET button for 5 seconds to access the general programming menu (see Diagram 1 at para. 4.3.1) Press the F1 button five times to switch to the Password Management sub-menu.
  • Page 11 HOW TO CHANGE THE SERVICE PASSWORD • Select “SERVICE PASSWORD” • Press OK (F1). • Enter the primary password • Enter the new service password, selecting a combination of 5 characters from the letters A-B-C-D. • You are prompted to repeat the new password, so enter again the previous combination •...
  • Page 12: T-Nfc Selector User Password Management

    4.7) T-NFC SELECTOR USER PASSWORD MANAGEMENT The selector T-NFC allows to prevent work program change by means of a password. This function is useful if you want to prevent unauthorized persons from setting the work program of the door. To do this, you need to activate the user password with the following steps: Press and hold button D for approximately 2 seconds.
  • Page 13: Language

    4.8) LANGUAGE To select the language on the selector ET-DSEL, perform the operations listed below: 1. Press the button for 5 seconds to enter the general programming menu. (see diagram 1 in the previous paragraph) 2. Press F1 three times to switch to the Language sub-menu. 3.
  • Page 14: Notification Of Errors And Operation Problems

    6) NOTIFICATION OF ERRORS AND OPERATION PROBLEMS PROBLEM LIKELY CAUSE SOLUTION The motion radars or the closing safety Check that the radars or the sensors are The door opens but it doesn't close back. sensor detect the presence of an object or not engaged.
  • Page 15: Maintenance

    7) MAINTENANCE The maintenance plan must be respected in order to ensure the service life and the safe operation of the automatic door. It is advisable to sign a maintenance contract that provides a periodic service visit on the system on the part of specialized technicians. If the user has the ET-DSEL or T-NFC digital program selector, he will be warned that the maintenance interval has expired when the message "PROGRAMMED MAINTENANCE"...
  • Page 16 LABEL service centre NEXT Made in Italy S.p.A Via Ilariuzzi, 17/A - S. Pancrazio P .se - 43126 PARMA - ITALIA CERTIFIED COMPANY QUALITY SYSTEM Tel. (+39) 05 21/ 67 52 - Fax (+39) 05 21/ 67 52 22 UNI EN ISO 9001:2000...