4-2-13 Replacement of fuse
Replace fuse of the controller when blowing.
The power of the laser marker cannot be turned on if the fuse is blown.
Models of replacement parts
Be sure to use the following type of fuse: If the user applies any other fuses than the specified one, failure might result.
Laser marker model
LP-S500, LP-S502, LP-S505
LP-S500W, LP-S505W
LP-S200, LP-S202, LP-S205
Steps for replacement
1.
Remove causes for fuse blowing.
2.
Turn OFF the key switch of the controller, and disconnect the AC power cable.
3.
Turn the fuse holder on the back side, and remove
the fuse.
4.
Replace it with new one.
5.
Turn the fuse holder, and install the fuse.
Type
Time Lag Fuse (Rating 250V 10A)
Time Lag Fuse (Rating 250V 6.3A)
ME-LPS-SSM-8
Model
0215010
(made by Littelfuse)
021506.3
(made by Littelfuse)
Fuse
holder
143