All manuals and user guides at all-guides.com Safety Symbol Legend Indicates a procedure, condition, or statement that, if not strictly observed, could result in personal injury or death. Warning Indicates a procedure, condition, or statement that, if not strictly observed, could result in damage to or destruction of equipment.
All manuals and user guides at all-guides.com Physical Characteristics The following diagrams illustrate the physical layout of the QuickPanel Operator Interface, including locations of status LEDs, communications ports, and connectors. 36 mm (1.42 in) x 2 192 mm (7.56 in) x 2 115.2 mm (4.5 in) SD Card...
Page 4
All manuals and user guides at all-guides.com Status SD Card Indicator LED MICRO USB Touchscreen LINE OUT MIC IN Input USB Host Power Ports Battery Cover IC755CxW07CDx Profile and Hardware Features Note: Refer to the table IC755CxW07CDx Specifications for drawing dimensions. QuickPanel Quick Start Guide GFK-2893K...
Page 5
All manuals and user guides at all-guides.com SD Card Status Indicator LED Touchscreen Input LAN1 MICRO COM1 LINE LAN2 COM2 Power Host Ports IC755CxS10CDx Profile and Hardware Features Note: Refer to the table IC755CxS10CDx Specifications for drawing dimensions. GFK-2893K QuickPanel Quick Start Guide...
Page 6
All manuals and user guides at all-guides.com IC755CxS12CDx Profile and Hardware Features Note: Refer to the table IC755CxS12CDx Specifications for drawing dimensions. QuickPanel Quick Start Guide GFK-2893K...
Page 7
All manuals and user guides at all-guides.com SD Card Status Indicator Touchscreen LINE Input LAN2 LAN1 MICRO COM2 COM1 Power Host Ports IC755CxS15CDx Profile and Hardware Features Note: Refer to the table IC755CxS15CDx Specifications for drawing dimensions. GFK-2893K QuickPanel Quick Start Guide...
All manuals and user guides at all-guides.com Specifications 2.1 Physical Specifications and Mounting Options IC755CxS06RDx Specifications Item Specification Freescale i.MX535 Processor (1 GHz ARM Cortex A8) DDR3 SDRAM 512 MB Memory NAND FLASH 256 MB SRAM 512 KB (with battery backup) Microsoft Windows Operating System Embedded Compact 7...
Page 9
All manuals and user guides at all-guides.com IC755CxW07CDx Specifications Item Specification Freescale i.MX535 Processor (1 GHz ARM Cortex A8) DDR2 SDRAM 512 MB Memory SLC NAND 256 MB SRAM 512 KB (with battery backup) Microsoft Windows Operating System Embedded Compact 7 Type 7”...
Page 10
All manuals and user guides at all-guides.com IC755CxS10CDx Specifications Item Specification Freescale i.MX535 Processor (1 GHz ARM Cortex A8) DDR3 SDRAM 1 GB Memory SLC NAND 512 MB SRAM 512 KB (with battery backup) Microsoft Windows Operating System Embedded Compact 7 Type 10.5”...
Page 11
All manuals and user guides at all-guides.com IC755CxS12CDx Specifications Item Specification Freescale i.MX535 Processor (1 GHz ARM Cortex A8) DDR3 SDRAM 1 GB Memory SLC NAND 512 MB SRAM 512 KB (with battery backup) Microsoft Windows Operating System Embedded Compact 7 Type 12.1”...
Page 12
All manuals and user guides at all-guides.com IC755CxS15CDx Specifications Item Specification Freescale i.MX535 Processor (1 GHz ARM Cortex A8) DDR3 SDRAM 1 GB Memory SLC NAND 512 MB SRAM 512 KB (with battery backup) Microsoft Windows Operating System Embedded Compact 7 Type 15”...
Page 13
All manuals and user guides at all-guides.com 2.2 Environmental Specifications Note: Install the QuickPanel in a well-ventilated location that is not exposed to dust, corrosive gases or liquids, rain, strong ultra- violet light or direct sunlight, and meets the following specifications. Item Specification (All Display Units) Cooling...
All manuals and user guides at all-guides.com Initial Startup Note: For installation requirements, complete installation procedures, and operating information, refer to the QuickPanel Operator Interface User Manual (GFK-2847). You will need the following: A Safety Extra Low Voltage (SELV) and Limited Energy Circuit or SELV and Class 2 dc power supply.
Page 15
All manuals and user guides at all-guides.com 3.1 QuickPanel Battery Installation Installing the battery should only be performed by trained personnel and in a non- hazardous location. If the QuickPanel is VESA mounted, detach from the VESA arm when replacing the battery.
Page 16
All manuals and user guides at all-guides.com To install the battery Remove the battery cover by pressing down while sliding outward. IC755CxS06RDx Battery Cover Removal Connect the battery harness connector to the header, noting keyed orientation. IC755CxS06RDx Battery Harness Connection Verify that positive (red) is down and negative (black) is up.
Page 17
Use of batteries not specified for use with the QuickPanel product may present a risk of fire or explosion. Warning Replace the battery for the IC755CxS06RDx only with GE battery part number IC755ACCBATT. Caution Replace the battery for the IC755CxW07CDx only with GE battery part number IC755ACCBATT.
Page 18
All manuals and user guides at all-guides.com 3.3 Connecting Input Power To connect input power Verify that the power cable is not energized. M2.5 Loosen the Mounting clamps screw clamps Screw clamps on the mating power connector. Strip the insulation from the power +24 V dc...
Page 19
All manuals and user guides at all-guides.com 3.4 LED Indicators 3.4.1 Operation Status LEDs The QuickPanel has one tri-color LED that provides visual operation status indication for the IC755CxS06RDx, IC755CxW07CDx, and IC755CxSxxCDx units. LED State QuickPanel State Amber, solid Operating system starting Green, solid Normal operating state Green, blinking...
All manuals and user guides at all-guides.com 4. Mounting and Installation 4.1 Protective Sheet Installation To install the protective sheet Remove the protective film from the QuickPanel display screen. Wipe the display unit of any dust or fingerprints. Peel back a corner of the clear side of the protective sheet.
Page 21
All manuals and user guides at all-guides.com 4.2 Mounting Location When mounting the QuickPanel Operator Interface, make sure the mounting area allows room to insert and remove the SD card, cables, and mounting brackets. Select a location that allows natural convection air flow from bottom to top of the QuickPanel enclosure.
Page 22
All manuals and user guides at all-guides.com 4.3 Panel Mounting To mount the QuickPanel in an enclosure, you will need the following equipment: • One #2 Phillips head screwdriver • Mounting brackets (supplied) The mounting holes for the IC755CxS06RDx, IC755CxW07CDx, and IC755CxS10CDx are located on the top and bottom sides of the unit.
Page 23
All manuals and user guides at all-guides.com IC755CxS10CDx Mounting Holes The IC755CxS12CDx and IC755CxS15CDx mounting holes are located on the top, bottom, and sides of the unit. IC755CxS12CDx Mounting Holes IC755CxS15CDx Mounting Holes GFK-2893K QuickPanel Quick Start Guide...
Page 24
All manuals and user guides at all-guides.com 4.4 Mounting and Installation Procedure When installing the QuickPanel into the panel, pay careful attention while handling the unit so it does not drop and damage the unit. Caution To install the QuickPanel Cut an opening in the panel according to the specifications in the following figures.
Page 25
All manuals and user guides at all-guides.com 266 mm (10.47 in) Panel Thickness: 1.6 to 5.0 mm (0.06 to 0.20 in) IC755CxS10CDx Panel Cutout Dimensions 302 mm (11.89 in) Panel Thickness: 1.6 to 5.0 mm (0.06 to 0.20 in) IC755CxS12CDx Panel Cutout Dimensions 379 mm (14.92 in) Panel Thickness: 1.6 to 5.0 mm...
Page 26
All manuals and user guides at all-guides.com Insert the hook of the mounting bracket into the mounting hole as displayed in the following figure. Tighten the screws on the mounting bracket in a clock-wise direction. Torque Range for Mounting Clamp Screws Display Unit Torque Range IC755CxS06RDx...
Page 27
All manuals and user guides at all-guides.com 4.5 VESA Arm Mounting The QuickPanel can be installed on a commercially available Video Electronics Standards Association (VESA) MIS-D arm, stand, or apparatus that complies with the UL1678 standard. To VESA mount the QuickPanel unit: use the mounting holes located on the back of the unit (displayed in the following figures).
Page 28
VESA Mounting Holes 100 mm 100 mm (3.94 in) IC755CxSxxCDx VESA Mounting Holes Note: For user manuals, product updates, and other information, go to the Support website, http://www.ge-ip.com/support and refer to Operator Interfaces and PC. QuickPanel Quick Start Guide GFK-2893K...
Page 29
All manuals and user guides at all-guides.com 4.6 Connectors 4.6.1 Power Connector Details Pin # Signal Name Pin-out † +24 V dc † IC755CxSxxCDA supports both +12 V dc or +24 V dc IN 4.6.2 Ethernet Port Details Interface: Ethernet 10BASE-T/100BASE-TX Pin # Signal Name Pin-out...
Page 30
All manuals and user guides at all-guides.com 4.6.4 Serial Port Details 4.6.4.1 IC755CxS06RDx 4.6.4.1.1 Serial Port COM1 Interface: RS-232 Pin # Signal Name SGND Pin 5 Pin 1 IC755CxS06RDx Serial Port COM1 Pin-out QuickPanel Quick Start Guide GFK-2893K...
Page 31
All manuals and user guides at all-guides.com 4.6.4.2 IC755CxW07CDx Interface: x1 RS-232 Signal Name Pin # SGND Pin 1 Pin 5 IC755CxW07CDx Serial Port COM1 Pin-out GFK-2893K QuickPanel Quick Start Guide...
Page 32
All manuals and user guides at all-guides.com 4.6.4.3 IC755CxSxxCDx 4.6.4.3.1 Serial Port COM1 Interface: RS-232 Pin # Signal Name SGND C755CxSxxCDx Serial Port COM1 Pin-out QuickPanel Quick Start Guide GFK-2893K...
Page 33
All manuals and user guides at all-guides.com 4.6.4.3.2 Serial Port COM2 Interface: RS-232C/485 (default is RS-485 Half-duplex) RS-232 RS-485 Pin # Signal Name Signal Name Signal † † Name (Full-duplex (Half-duplex ‡ TXD+ DATA+ ‡ TXD- DATA- ‡ RXD+ DATA+ ‡...
Page 34
All manuals and user guides at all-guides.com 5. Product Certifications and Installation Guidelines for Conformance The QuickPanel Operator Interface is intended for use in industrial environments and, when properly installed, shall comply with the following agency approvals. 5.1 Agency Approvals Note: The agency approvals listed in the following table and on the Declaration of Conformities are believed to be accurate;...
Page 35
All manuals and user guides at all-guides.com Electromagnetic Compatibility Directive Self-declaration in accordance with European Directives European Electromagnetic EN61000-6-2, Compatibility (EMC) for Industrial Control EN61000-6-4 Equipment Det Norske Veritas (DNV) certification only applies to Maritime Society QuickPanel 7'' Display Certification marking unit (part number IC755CSW07CDACA)
Page 36
All manuals and user guides at all-guides.com The equipment shall be installed in an enclosure that provides a minimum ingress protection of IP 54 in accordance with IEC 60079-0. Transient protection shall be provided that is set at a level not exceeding 140% of the peak rated voltage value at the supply terminals to the equipment.
All manuals and user guides at all-guides.com EXPLOSION HAZARD - Do not connect or disconnect equipment power, communication, audio, or battery unless power has been removed or the area is known to be non-hazardous. EXPLOSION HAZARD - Substitution of components may impair suitability.
Page 38
Changes or modifications to this unit that are not expressly approved by GE Intelligent Platforms could void the user’s authority to operate the equipment. Industry Canada requires the following note to be...
Page 39
All manuals and user guides at all-guides.com 5.4 EMC Installation and Operation Considerations This equipment is intended for industrial use only and complies with a minimum level of EMC performance as defined by EN 61000-6-2 and EN 61000-6-4 standards. To meet these requirements, the following installation and operation considerations were taken into account: •...
Page 40
All manuals and user guides at all-guides.com GE Intelligent Platforms Contact Information If you purchased this product through an Authorized Channel Partner, contact the seller directly. General Contact Information Online technical support and http://support.ge-ip.com GlobalCare Additional information http://www.ge-ip.com/ Solution Provider solutionprovider.ip@ge.com...