Key Features
• Highly Expandable:
Up to 6 additional monitors can be connected to the main monitor using a combination of 7-inch wired monitors and 2.2-inch wireless monitors (However, the
maximum possible number of 7-inch wired monitors is 3). In addition, PBX connectivity is also supported.
• Wireless Monitor:
Using the wireless monitor, check visitors and respond promptly from the living room, kitchen and elsewhere in the home even while you
are doing something else. Up to 6 wireless monitors connectable. Max wireless range is 100 m with no obstacles. You can add on repeaters to expand the range.
Up to 2 DECT repeaters connectable.
• 7-inch Screen:
The main monitor and extension monitor have a 7-inch wide screen that offers easy viewing of wide vertical and horizontal views.
• Voice Change Function:
• Electric Lock Release Support for Gate:
The gate or door lock can be easily and quickly released using monitors (wired or wireless) from anywhere in the house.
• Wide-Angle Camera:
Wide-angle lens covers approximately 170 degrees horizontally and 115 degrees vertically.
• Picture Recording Function:
sessions. (up to 8 still images per visitor/session)
• Night Vision with LED lights (illumination lamp):
Door station is equipped with LED lights (illumination lamp). It enables the colour display of visitors at a distance of about 50 cm at night.
Wiring Schematic Diagram
DOORPHONE 1
D1 D2 S1 S2
MAIN MONITOR
NP
1
D1
2
D2
3
D3
4
D4
NP
5
Ml-1
6
Ml-2
7
MO-1
NP
8
MO-2
9
MO-3
NP
10
MO-4
11
MO-5
NP
12
MO-6
13
IN1
NP
14
IN2
15
IN3
NP
16
IN4
17
P1
NP
18
P2
19
S1
NP
20
S2
21
S3
22
S4
NP
*4
NP
220-240 V AC
Power
supply
*5
Electric lock
24 V DC
POWER SUPPLY UNIT
*1 When you use an additional doorphone, the maximum number of the electric locks that can be connected to the
doorphone depends on the type of doorphone. Consult your dealer for further information.
For VL-V554 users:
- Make sure to only connect electric door locks to the S1/S2 terminals of the doorphones.
*2 You can also connect an optional lobby station or Video Intercom System for Apartment Complexes.
*3 Connection devices for option input (A contact) can be used when a VL-V900 and VL-V700 series Video Intercom System
for Apartment Complexes is used.
- Make sure to connect emergency terminals to the IN1/IN2 terminals.
- Make sure to connect doorbells to the IN3/IN4 terminals. A doorbell and doorphone 2 cannot be used together.
*4 VL-MWD273BX/VL-MWD273ML models only
*5 VL-SWD273AZ/VL-SVD273AZ/VL-MWD273AZ: Use only the supplied AC cable.
Optional Accessories
Door Station (Doorphone)
CMOS 1.0 M pixels
VL-V554
(Surface mount)
VL-V554U
(Flash mount)
CMOS 0.3 M pixels
VL-V555
(Surface mount)
This function makes woman's voice (higher keys) sounds like a man's (lower keys).
The main monitor and extension monitor can record doorphone images from up to 50 doorphone calls or monitoring
*1
*1
DOORPHONE 2
D1 D2 S1 S2
Electric lock
Power supply
*2
Power supply
EXTENSION
5
Ml-1
MONITOR 1
6
Ml-2
EXTENSION
5
Ml-1
MONITOR 2
6
Ml-2
EXTENSION
5
Ml-1
MONITOR 3
6
Ml-2
Connection device for
*3
option input (A contact)
Terminal box
(4-conductor wiring)
Power
supply
Electric lock
PBX
NP: Non-polarised
Door Station
Extension Monitor
(Doorphone)
VL-MWD273
VL-V522L
VL-MWD272
(Surface mount)
(Power source)
VL-MWD273: 24 V DC Power supply unit (supplied)
VL-MWD272: 220-240 V AC, 50/60 Hz
Wireless Video Intercom System
Wire type and length
Wiring run
Doorphone –
Main monitor –
*7
Extension monitor
Electric lock
Main monitor –
Power supply unit
Power supply unit –
AC power source
*8
Main monitor – Electric lock
*8
Doorphone – Electric lock
Main monitor – Connection device
*8
for option input (A contact)
Main monitor – PBX
*6 Type: Single-pair cable with outer sheath (jacket)
Conductor: Copper solid
• A certified power supply wiring has to be used with this equipment. The relevant national installation and/or
equipment regulations shall be considered. A certified power supply wiring not lighter than ordinary polyvinyl
chloride flexible wiring according to IEC 60227 shall be used.
*7 When an extension monitor is used, make sure that the total wiring length from the doorphone to the main
monitor and then to the extension monitor, is within about 100 m.
*8 When using an electric lock or a connection device for option input (A contact), select a device that meets the
following guidelines:
• Electric lock connection terminal (S1/S2, S3/S4):
- N/O dry closure contact
- 30 V AC (1 A)/24 V DC (1 A) or lower
• Connection device for option input (A contact) terminal (IN1/IN2/IN3/IN4):
- Input method: No-voltage contact
- Open-circuit voltage between terminals: DC 7 V or less
- Detection definite time: 0.1 seconds or more
- Short-circuit between terminals: 5 mA or less
- Resistance value: make: 500 Ω or less, break: 15 KΩ or more
Wireless
Monitor Station
(Sub monitor)
VL-WD613
VL-SWD273
VL-SVD273
VL-SVD273:
Wireless monitors sold separately
*6
Wire type
Diameter
Length (Max.)
φ 0.65 mm
22 AWG
φ 1.0 mm
18 AWG
φ 0.5 mm
CAT 5
φ 0.65 mm
22 AWG
φ 1.0 mm
18 AWG
φ 1.2 mm - φ 2.0 mm
No requirement
(17 AWG - 12 AWG)
φ 0.5 mm - φ 1.2 mm
According to the specification
of connected device.
(24 AWG - 17 AWG)
φ 0.5 mm - φ 1.2 mm
According to the specification
of connected device.
(24 AWG - 17 AWG)
φ 0.5 mm - φ 1.2 mm
According to the specification
of connected device.
(24 AWG - 17 AWG)
φ 0.65 mm
CAT 3 or 22 AWG
DECT Repeater
Lobby Station
VL-FKD2
Up to 20 main
monitors can
be connected.
100 m
130 m
50 m
10 m
20 m
100 m