hit counter script
ABB Ability User Manual

ABB Ability User Manual

Edge industrial gateway
Hide thumbs Also See for Ability:

Advertisement

Quick Links

U S E R M A N UA L
ABB Ability
TM
Edge Industrial Gateway

Advertisement

Table of Contents
loading

Summary of Contents for ABB Ability

  • Page 1 — U S E R M A N UA L ABB Ability Edge Industrial Gateway...
  • Page 2 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 3 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Trademarks All trademarks, registered trademarks, logos, trade names, products names contained in this document are the property of their respective owners.
  • Page 5 INTRODUCTION — CONVENTIONS USED IN THIS DOCUMENT ABB Ability Edge Industrial Gateway PRODUCT OVERVIEW Index NORMS AND CERTIFICATIONS INTERFACES OVERVIEW INTERFACES IN DETAIL MECHANICAL SPECIFICATIONS HOW TO INSTALL THE PRODUCT HOW TO SUPPLY POWER TO THE PRODUCT HOW TO MAINTAIN...
  • Page 7: Table Of Contents

    A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Introduction 1.1 Contents 1.1.1 Overview 1.1.2 Recipients 1.2 Safety 1.2.1 Safety prescriptions 1.2.2 Warnings 1.3 Cybersecurity 1.3.1 Disclaimer...
  • Page 8: Overview

    All the remaining tasks described in the manual must be performed by trained persons in an electrical environment. ABB accepts no liability for damage to property or personal injury due to failure to comply with the instructions contained in this document.
  • Page 9: Warnings

    • Install the unit in compliance with the environmental, electrical and mechanical limits described in the product documentation. • ABB Ability™ Edge Industrial Gateway has been designed to operate with voltage and current values within the rated limits: do not install in systems that work at values exceeding these rated limits.
  • Page 10: Cybersecurity

    ABB and its affiliates are not liable for damage and/or losses related to such security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information.
  • Page 11: Warning Messages For Damage To Property

    A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY To indicate a potentially hazardous situation which, if not avoided, could result in minor or moderate injury, the following message is used: CAUTION! Sign (if necessary)
  • Page 13 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Conventions used in this document 2.1 Conventions for signal names 2.2 Conventions for signal types...
  • Page 14 2.1 Conventions for signal names Convention Description Ground Active low signal Positive signal; Positive signal in differential pair Negative signal; Negative signal in differential pair 3.3 V signal level 5 V signal level No Connection Reserved Use is reserved to ABB...
  • Page 15 2.2 Conventions for signal types Convention Description Signal is an input to the system Signal is an output from the system Signal may be input or output Power and Ground Analog signal No Connection Reserved Use is reserved to ABB...
  • Page 16 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 17 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Product overview 3.1 Product description 3.2 Product models 3.3 Intended use and not allowed uses of the product 3.3.1 Intended use 3.4 Technical specifications...
  • Page 18 ABB Ability™ Edge Industrial Gateway is an independent IoT gateway which can gather data from field devices – as well as consumption of water and gas, among others – and connect the system to ABB Ability™ Energy and Asset Manager, our cloud platform. As a result, all downstream field devices can be monitored from the cloud via an Ethernet cable, wi-fi or mobile connectivity.
  • Page 19 • Must include an external 2 A fuse on the line coming from the negative terminal. — 3.4 Technical specifications The ABB Ability™ Edge Industrial Gateway family is available either as cloud-connected or local view model with the following connectivity options: • ABB Ability™ Edge Industrial Gateway standard version.
  • Page 20 The following labels are placed on the product: — Label example Label type and content Label position the symbol Part Number Label ABB and Eurotech stands for direct current logo Manufacturer name Manufacturer address (EU versions only) Product number Model number (xx = product version)
  • Page 21 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 22 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 23 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Norms and certifications 4.1 CE Marking 4.2 Directive RED 2014/53/EU 4.2.1 Modification statement 4.3 FCC Marking 4.4 FCC/ISED regulatory notices...
  • Page 24 Some versions of the product described in this document are CE marked; for more information see “Technical Specifications” on page 19. ABB is not responsible for the use of this product together with equipment (for example: power supplies, personal computers, etc.) that are not CE marked and not compliant with the requirements specified in this document.
  • Page 25 2.5 GHz Wi-Fi 802.11a,b,g,n / BLE 4.2 BLE 5.47 dBi Wi-Fi / Bluetooth 50Ω Dipole Bluetooth 5 GHz Wi-Fi 802.11a,b,g,n 7.07 dBi The ABB Ability™ Edge Industrial Gateway has been certified with the following antennas: Types Manufacturer and Model Bands Peak Gain (dBi) VSWR 2.40–2.483 MHz...
  • Page 26 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY However, there is no guarantee that interference will not occur in a particular installation. If this product does cause harmful interference to radio or television reception, which can be determined by turning the product OFF and ON, the user is encouraged to try to correct the interference by one or more of the following measures:...
  • Page 27 4.5.1 EU restrictions on 5 GHz Wi-Fi usage Due to EU restrictions on 5 GHz Wi-Fi bands the ABB Ability™ Edge Industrial Gateway is limited to indoor operation and should only be operated in the frequency band 5150 MHz – 5250 MHz (U-NII-1) covering 20 MHz channels (36,40,44,48) and 40 MHz channels(38,46).
  • Page 28 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 29 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Interfaces overview 5.1 Front side interfaces overview 5.2 Rear side interfaces overview 5.3 Service panel interfaces 5.4 Right side interface overview 5.5 Left side interface overview...
  • Page 30 Description Antenna connector for 2.4 GHz Wi-Fi / Bluetooth Main antenna connector for Internal Cellular Modem: CELL MAIN (only for ABB Ability™ Edge Industrial Gateway with 3G) Reserved Diversity antenna connector for Internal Cellular Modem: CELL DIV (only for ABB Ability™ Edge Industrial Gateway with 3G)
  • Page 31 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — 5.2 Rear side interfaces overview The Rear Side Interfaces are as follows: —...
  • Page 32 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — 5.4 Right side interface overview The Right Side Interface is as follows: —...
  • Page 33 LED OFF: System OK LED ON: Error Amber N/A (ABB Ability™ Edge Industrial Gateway std version) CELLULAR (ABB Ability™ Edge Industrial Gateway with 3G) LED ON: Internal Cellular Modem ON LED Blinking: Internal Cellular Modem connected to cellular network Green...
  • Page 34 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 35 — Interfaces in detail 6.1 Wi-Fi 6.1.1 Wi-Fi specifications 6.2 Internal cellular modem (only for ABB Ability™ Edge Industrial Gateway with 3G with cellular connectivity) 6.2.1 Internal cellular modem specifications (according to product versions) 6.2.2 LTE - single antenna operation notes 6.2.3 Main antenna requirements...
  • Page 36 — Interfaces in detail — 6.1 Wi-Fi The ABB Ability™ Edge Industrial Gateway provides the following Wi-Fi function: 2.5 GHz Wi-Fi 802.11a,b,g,n / 5 GHz Wi-Fi 802.11a,b,g,n. The antennas connectors are placed on the front side. 6.1.1 Wi-Fi specifications • Integrated 2.4 & 5G GHz Power Amplifier (PA) for WLAN solution.
  • Page 37 Single LTE antenna operation can be supported; however, typically, wireless carriers (Mobile Network Operators) impose restrictions. Please consult with your carrier before considering single LTE antenna usage. For optimum performance of the cellular interface, ABB recommends the use of both CELL MAIN and CELL DIV antenna connectors.
  • Page 38 VSWR recommended ≤ 2:1 6.2.5 The MicroSIM card holders The ABB Ability™ Edge Industrial Gateway includes the following MicroSIM card holders: • 1st MicroSIM card holder: • Integrated in a Combo MicroSD (push-pull) + MicroSIM (pull-lever) cards holder. • Placed on the top side of the circuit board in the Service Panel.
  • Page 39 COM 1 has 2 pairs of pins (each signal is doubled): • If the ABB Ability™ Edge Industrial Gateway is located at the beginning, or at the end, of a RS-485 chain, spare pair of pins can be used to connect permanently standard axial resistor 120Ω, if the application requires that.
  • Page 40 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY 6.3.4 COM connector specifications Connector Layout: Connector Pinout: Pin # Signal Type Description COM port 0:...
  • Page 41 E D G E I N D U S T R I A L G AT E W AY — 6.4 Ethernet ports The ABB Ability™ Edge Industrial Gateway provides 2x 10/100 Mbps Ethernet ports: • ETH 0. • ETH 1 (Local LAN).
  • Page 42 E D G E I N D U S T R I A L G AT E W AY — 6.5 Host USB ports The ABB Ability™ Edge Industrial Gateway provides 3x Host 2.0 USB ports (Noise and Surge Protected) for general purpose applications: • USB 0 on the rear side; max load: 500 mA.
  • Page 43 E D G E I N D U S T R I A L G AT E W AY — 6.6 Expansion connector The ABB Ability™ Edge Industrial Gateway provides, on the right side, an expansion connector with the following interfaces: • I/O additional Module.
  • Page 44 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 45 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Mechanical specifications Product mechanical dimensions 7.2 Mounting bracket mechanical dimensions...
  • Page 46 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Mechanical specifications — 7.1 Product mechanical dimensions The product electronics are housed in an ABS enclosure having the following dimensions: 139 (L) x 115 (W) x 46 (H);...
  • Page 47 E D G E I N D U S T R I A L G AT E W AY — 7.2 Mounting bracket mechanical dimensions The Mounting Bracket fastened on the bottom side of the ABB Ability™ Edge Industrial Gateway has the following dimensions. ll dimensions are in millimeters.
  • Page 48 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 49 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — How to install the product 8.1 How to install the product using the mounting bracket 8.2 How to replace the mounting bracket with the DIN rail mounting clip or vice versa...
  • Page 50 The product must be installed in a secured location, accessible to authorized personnel only (for example in a cabinet / technical compartment). By default, the ABB Ability™ Edge Industrial Gateway comes with a DIN rail mounting clip fastened on the bottom side. You can use this to install the ABB Ability™ Edge Industrial Gateway.
  • Page 51 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — 8.2 How to replace the mounting bracket with the DIN rail mounting clip or vice versa 8.2.1 How to replace the mounting bracket with the DIN rail mounting clip To replace the Mounting Bracket with the DIN Rail Mounting Clip on the product, complete...
  • Page 52 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY 8.2.2 How to replace the DIN rail mounting clip with the mounting bracket To replace the DIN Rail Mounting Clip with the Mounting Bracket on the product, complete the following steps:...
  • Page 53 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — 8.3 How to install/remove the product on/from a DIN rail 8.3.1 How to install the product on a DIN rail Prerequisite: Replace the Mounting Bracket with the DIN Rail Mounting Clip To install the product on a horizontal DIN rail, complete the following steps:...
  • Page 54 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 55 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — How to supply power to the product 9.1 How to supply power to the product 9.1.1 Power IN connector and mating connector specifications 9.2 How to supply power and turn ON the product...
  • Page 56 NOTICE The Power IN connector is NOT protected against short circuit. Always include an external fuse to protect the product! The ABB Ability™ Edge Industrial Gateway provides the Power IN connector on the rear side. Connector layout: Connector Pinout: Pin #...
  • Page 57 9. Connect power after the installation of the system has been completed. 10. Never connect or disconnect the cables with the system or the external apparatus switched ON. To supply power and turn ON the ABB Ability™ Edge Industrial Gateway, complete the following steps: 1. Setup a DC power source that: •...
  • Page 58 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 59 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — How to maintain the product 10.1 How to safely remove the power supply 10.2 How to verify the installation of the product 10.3 How to clean the product...
  • Page 60 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — How to maintain the product Periodically inspect the product to verify its integrity and to ensure proper operation. To maintain the product, complete the following steps: 1.
  • Page 61 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 62 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 63 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Cyber Security Deployment Guideline 11.1 Secure system setup 11.1.1 Basic system hardening rules 11.2 Access control (Local view) 11.2.1 Web server access 11.2.2 User accounts...
  • Page 64 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Cyber Security Deployment Guideline — 11.1 Secure system setup 11.1.1 Basic system hardening rules Today's distribution automation systems are basically specialized IT systems.
  • Page 65 — 11.2 Access Control (Local view) This section describes system hardening measures that can be taken to limit access to various components in ABB Ability Edge Industrial Gateway only for users with predefined permissions/ access rights. 11.2.1 Web server access By default, Edge Gateway Web Server will have only below User ID and password from FACTORY: User ID: OWNER@abb.com...
  • Page 66 11.2.3 SSH (Secure Shell) Access - only for developer & maintenance role In ABB Ability Edge Industrial Gateway, SSH (Secure Shell) is NOT available for customer and is disabled. This is available only to internal ABB Developers & Maintenance Role users for debugging purpose.
  • Page 67 E D G E I N D U S T R I A L G AT E W AY 11.2.4 Adding Gateway hostname in client machine (Windows) For the device name to be used with communications (example: https://xxx.elgateway.abb.local:5003) user computer needs to have host defined in hosts file. This can be added with Administrative rights,...
  • Page 68 Web server is only available in Local view version. To access the web server, user need to replace “xxx” below with the digits 4 to 7 (for example A490050..000 → 0050) of the ABB Gateway Serial number: https://xxx.elgateway.abb.local:5003 For example: https://006.elgateway.abb.local:5003...
  • Page 69 IP Address, Port and a communication protocol. A communication protocol, such as HTTP, Modbus TCP, signifies a set of rules to be used when sending/receiving data over the network. The table below list the ports used by various software processes in ABB Ability Edge Industrial Gateway accomplishing a specific functionality.
  • Page 70 Internal firewall is a software application which allows or blocks any software program executing within ABB Ability Edge Industrial Gateway from establishing a connection on the network. The network connection can be an outgoing connection initiated from ABB Ability Edge Industrial Gateway or an incoming connection to ABB Ability Edge Industrial Gateway.
  • Page 71 11.6 Security event monitoring (Local view) Audit policies provide a means to monitor various actions by a user or a software process in ABB Ability Edge Industrial Gateway. The events generated by a specific audit policy denote a success or failed result for some action.
  • Page 72 11.6.1 Web server security events (only for Edge Gateway) Audit policies provide a means to monitor various actions by a user or a software process in ABB Ability Edge Industrial Gateway. The events generated by a specific audit policy denote a success or failed result for some action.
  • Page 73 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY 11.6.3 System security events For system audit log events, below are the events which will be logged: Sr.
  • Page 74 The firmware update process in Gateway is initiated with Provisioning Tool sending the relevant information to the Gateway to download the firmware file from ABB hosted cloud. With this download process in initiated and once it is completed, Gateway will apply the update & reboot gateway.
  • Page 75 In case any errors are detected, the reader is kindly requested to notify the manufacturer. Other than under explicit contractual commitments, in no event shall ABB be responsible or liable for any loss or damage resulting from the use of this manual or the application of the equipment.
  • Page 76 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 77 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Annex 1: additional I/O module 12.1 Product labels 12.2 Configuration...
  • Page 78 I/O module is a fast and simple way to expand the capabilities of ABB Ability™ Edge Industrial Gateway with extra digital and analog ports. Designed to be fitted to the side of the ABB Ability™ Edge Industrial Gateway, it is rated for the same level of reliability and operating temperature range.
  • Page 79 E D G E I N D U S T R I A L G AT E W AY — 12.2 Configuration The additional IO module can be confirued using Provision Tool. Please refer to: ABB Ability™ Energy and Asset Manager Cloud Provisioning Guide...
  • Page 80 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 81 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Declaration of conformity 13.1 CE Marking 13.2 WEEE compliance 13.3 RoHS 2 compliance 13.4 Electromagnetic compatibility 13.4.1 Electromagnetic compatibility (for EU)
  • Page 82 The product meets the guidelines listed in the following sections. ABB is not responsible for the use of this product together with equipment (eg power supplies, personal computers, etc) that are not CE marked and compliant with the requirements specified in this document.
  • Page 83 ADC Conversion: 12 bit Sigma Delta Sampling Frequency: 1kHz Max Input I/O interfaces Analog Input Protection Circuitry (5kV DC) Other LEDs 4x Digital Output Status 2x Input Provided by ABB Ability™ Edge Industrial Gateway Power Consumption 0.3W Typical Operating Temp -25 °C to +85 °C Environment Storage Temp -40 °C to +85 °C...
  • Page 84 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 85 E D G E I N D U S T R I A L G AT E W AY — Mechanical specifications How to install the product 14.1 I/O module mechanical dimensions 14.2 How to install the product 14.2.1 How to attach I/O module to ABB Ability™ Edge Industrial Gateway...
  • Page 86 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Mechanical specifications How to install the product — 14.1 I/O module mechanical dimensions The I/O modules are housed in an ABS enclosure having the following dimensions: 90.3 (W) x 59.0 (L) x 43.7 (H);...
  • Page 87 • Attach the I/O additional module 10-12-xx unit to the ABB Ability™ Edge Industrial Gateway as shown below using M2.5 x 5 CAP Head screw. • Screw the I/O additional module module mounting plate to the same flat surface as the ABB Ability™ Edge Industrial Gateway.
  • Page 88 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 89 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Basic configuration via provisioning tool 15.1 Connect 15.2 Configuration 15.3 Connectivity (Ethernet settings) 15.4 Wifi settings (Cloud-connected) 15.5 Cellular settings (Cloud-connected)
  • Page 90 Be sure that your laptop is connected directly to ETH1 of the EL Edge Gateway. The ABB Ability™ Edge Industrial Gateway is configured using windows based ABB Provisioning Tool. After installation of the tool and after the login the user will find a gateway configuration button called "Configure the gateway".
  • Page 91 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY After clicking "Start Discovery": • If automatic discovery is selected, the auto-scan process starts with visual feedback of the status (like on gateway discovery for provisioning).
  • Page 92 The connectivity page has configuration • internet setting (ETH0). • connection needed for firmware update (local view). • connection to ABB cloud (cloud-connected) • Device settings (ETH1). • devices connected to gateway (local LAN). • Site Manager (Local view only).
  • Page 93 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — 15.4 Wifi settings (Cloud-connected) Cloud connection can be established also via WLAN network. Settings can be changed using Connectivity page.
  • Page 94 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 95 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Annex 2: Web server Configuration (Local view) 16.1 Configuration of the connections to web server 16.2 Navigation to web server...
  • Page 96 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — Annex 2: Web server Configuration (Local view) — 16.1 Configuration of the connections to web server The FACTORY shipped device will have below configuration steps A.
  • Page 97 E. Install certificates & configure hostname in windows machine (please refer CSDG section no. ) Include if any certificate needed for CCT?? F. Link: https://xxx.elgateway.abb.local where xxx – is the last 3-digits of ABB device Serial number, please check the label of the ABB Ability™ Edge Industrial Gateway for serial number.
  • Page 98 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY — 16.2 Navigation to web server a. Web Server Dashboard • Only 1-dashboard & 28-widgets available in Web server with max. 15 widgets can be added to the dashboard at a time.
  • Page 99 A B B A B I L I T Y E D G E I N D U S T R I A L G AT E W AY...
  • Page 100 The information contained in this document is for general information purposes only. While ABB strives to keep the information up to date and correct, it makes no representations or warranties of any kind, expressed or implied, about the completeness,...

Table of Contents