Summary of Contents for Siemens SIMEAS-Hub 7KE6000-8AD /CC
Page 1
7KE6000-8AD /CC 7KE6000-8AE /CC Betriebsanleitung/Operating Instructions Bestell-Nr./Order No.: E50417-K1074-C299-A1 Hinweise für den Einsatz Deutsch: Seite 3 SIMEAS-Hub Directions for use English: page 27 SIMEAS-Hub Copyright Siemens AG 2004...
Page 2
Subject to change without prior notice. Release: 1.00.04 tered trademarks of SIEMENS AG. All other product and brand names in these operating instructions might be trademarks, the use of which by third persons for their purposes might infringe the rights of their respective owners.
Betriebsmittel zur Verwendung innerhalb bestimmter Spannungsgrenzen (Niederspan- nungsrichtlinie 73/23/EWG). Diese Konformität ist das Ergebnis einer Prüfung, die durch die Siemens AG gemäß Artikel 10 der Richtlinie in Übereinstimmung mit den Fachgrundnormen EN 61000-6-4 und EN 61000-6-2 für die EMV-Richtlinie und der Norm EN 61010-1 für die Niederspannungs- richtlinie durchgeführt worden ist.
SIMEAS-Hub Deutsch Hinweise und Warnungen Die Hinweise und Warnungen in dieser Betriebsanleitung sind zu Ihrer Sicherheit und einer angemessenen Lebensdauer des Gerätes zu beachten. Folgende Signalbegriffe und Standarddefinitionen werden dabei verwendet: GEFAHR bedeutet, dass Tod, schwere Körperverletzung oder erheblicher Sach- schaden eintreten wird, wenn die entsprechenden Vorsichtsmaßnah- men nicht getroffen werden.
Page 6
Deutsch SIMEAS-Hub WARNUNG Beim Betrieb elektrischer Geräte stehen zwangsläufig bestimmte Teile dieser Geräte unter gefährlicher Spannung. Nichtbeachtung kann Tod, Körperverletzung oder erheblichen Sach- schaden zur Folge haben. Nur entsprechend qualifiziertes Personal soll an diesem Gerät oder in dessen Nähe arbeiten. Dieses muss gründlich mit allen Warnungen und Instandhaltungsmaßnahmen gemäß...
Instandhaltung berücksichtigen. Sollten Sie weitere Informationen wünschen, oder sollten besondere Probleme auftreten, die in dieser Unterlage nicht ausführlich genug behandelt werden, dann fordern Sie bitte die benötigte Auskunft von Ihrer örtlichen Siemens-Nieder- lassung an, oder wenden Sie sich direkt an unsere Kontaktadresse (siehe Seite 52).
Deutsch SIMEAS-Hub Aus- und Einpacken des Gerätes Die Geräte werden im Werk so verpackt, dass sie die Anforderungen nach IEC 60255-21 erfüllen. Das Aus- und Einpacken ist mit der üblichen Sorgfalt ohne Gewaltanwendung und nur unter Verwendung von geeignetem Werkzeug vorzunehmen. Die Geräte sind durch Sichtkontrolle auf einwandfreien mechanischen Zustand zu überprüfen.
SIMEAS-Hub Deutsch Verwendung Mit dem SIMEAS-Hub kann eine Kopplung von mehreren Segmenten realisiert werden. Dabei wird jedes Signal vom SIMEAS-Hub auf die angeschlossenen Segmente übertragen (10Base-T / 10Base-FL). Weiterhin kann der SIMEAS-Hub auch zur Signalregenerierung verwendet werden (Repeater-Funktion). Zum Betrieb des SIMEAS-Hub werden keine Software-Komponenten benötigt. Eine Para- metrierung des SIMEAS-Hub ist nicht notwendig.
Deutsch SIMEAS-Hub Funktion Bild 1 Blockschaltbild des SIMEAS-Hub Bild 1 zeigt die Funktionsweise des SIMEAS-Hub. Der vorliegende SIMEAS-Hub besitzt sechs Anschlüsse für 10Base-T und einen 10Base-FL Anschluss. Eigenschaften: Erfüllt Spezifikation IEEE 802.3 Ethernet Version 1.0 und 2.0 kompatibel 6 Twisted Pair 10Base-T Anschlüsse 1 Lichtwellenleiteranschluss 10Base-FL Automatische, taktgerechte Signalregenerierung Kollisionserkennung...
Page 11
SIMEAS-Hub Deutsch Für die 10Base-FL Ports wurde ein Link-Integritätstest definiert. Um sicherzustellen, dass die Verbindung in beiden Richtungen aktiv ist, werden von 10Base-FL-Repeatern, wie auch von 10Base-FL-Endgeräten, in regelmäßigen Abständen neben den eigentlichen Datensig- nalen Link-Integritätssignale an das gegenüberliegende Gerät gesendet. LEDs: Sechs LEDs zeigen die Verbindung für jeden Port an.
Page 12
Deutsch SIMEAS-Hub A-F: Link-Status-LED (grün) Für jeden 10Base-T Anschluss existiert eine Link-Status-LED. Diese LED leuchtet, wenn die Twisted Pair Leitung des entsprechenden Ports korrekt verbunden ist, wenn der Port einen gültigen Link empfangen hat und die automatische Separation fehlerhafter Netz- segmente freigegeben wurde.
SIMEAS-Hub Deutsch Anschlusshinweise Hilfsenergieanschluss Direktanschluss: Massivleiter oder Litzenleiter mit Aderendhülse für Leitungsquerschnitte von 0,5 mm bis 2,5 mm (entsprechend AWG 22 bis 12). Die Spannungsfestigkeit der Anschlussleitungen muss min. 300 V AC betragen. Drehmoment: min 0,5 Nm. Der maximale Nennstrom des Gerätes beträgt 0,5 A. Um eine ausreichende Selektivität in der Sicherungskette zu gewährleisten, sollte der vorgeschaltete Leitungsschutzschalter mindestens 2 A betragen.
Deutsch SIMEAS-Hub Montage Warnung Beim Betrieb elektrischer Geräte stehen zwangsläufig bestimmte Teile dieser Geräte unter gefährlicher Spannung. Bei Nichtbeachtung der Bedienhinweise können deshalb schwere Körperverletzungen oder Sachschäden auftreten. Montage und elektrischer Anschluss des Geräts sollten nur durch ent- sprechend qualifiziertes Personal vorgenommen werden. Insbesondere müssen alle Warnhinweise unbedingt beachtet werden.
SIMEAS-Hub Deutsch Inbetriebsetzung Prüfen Sie, ob die Betriebsdaten mit den Werten auf dem Typenschild übereinstimmen. Nehmen Sie am SIMEAS-Hub keine Veränderungen vor. Schnappen Sie den SIMEAS-Hub mittels der Gehäuseschnappbefestigung auf eine Hutschiene auf. Schließen Sie die 10Base-T-Kanäle an die RJ45-Buchsen (10Base-T Ports A … F) an. Schließen Sie, wenn vorhanden, den 10Base-FL-Kanal über die Sendediode die Empfangsdiode mittels F-SMA Schraubverbindung an.
SIMEAS-Hub Deutsch Technische Daten Hilfsenergie U Nenneingangsspannung U - Gleichspannung 24 … 60 V DC; 110 … 250 V DC - Wechselspannung 100 … 230 V AC; 45 … 65 Hz Eingangsbereich - Gleichspannung ±20% - Wechselspannung ±20% Leistungsaufnahme - Gleichspannung - Wechselspannung 15 VA vorzuschaltende Sicherung...
Page 20
Deutsch SIMEAS-Hub Sicherheit nach IEC/EN 61010, Teil 1 (VDE 0411 Teil 1) Überspannungskategorie Verschmutzungsgrad Brandbeständigkeitsklasse des Gehäuses V0 nach UL94 Spannungsprüfungen (Typprüfung) 10Base-T Ports gegen Hilfsspannung U = 5,2 kV DC / 1 min Stoßspannung nach IEC 60255-5 (Typprüfung) 5 kV Spannungsprüfung (Stückprüfung) 10Base-T Ports gegen Hilfsspannung U = 3,1 kV DC / 2 s...
Page 21
SIMEAS-Hub Deutsch Mechanische Prüfungen Schwing- und Schockbeanspruchung IEC 60255-21 und IEC 60068 bei stationärem Einsatz - Schwingung IEC 60255-21-1, Klasse 2, IEC 60068-2-6 - Schock IEC 60255-21-2, Klasse 1, IEC 60068-2-27 - Schwingung bei Erdbeben IEC 60255-21-3, Klasse 1, IEC 60068-3-3 Schwing- und Schockbeanspruchung IEC 60255-21 und IEC 60068-2 beim Transport...
SIMEAS-Hub Deutsch Bestellhinweise Benennung Bestellnummer Kurzangabe SIMEAS-Hub – ↑ Hilfsenergie DC 24 … 60 V DC 110 … 250 V AC 100 … 230 V; 45 … 65 Hz Wartung, Instandsetzung und Reinigung Die Geräte 7KE6000 bedürfen keiner besonderen Wartung. Sie können bei Bedarf in einem Labor geprüft werden.
Deutsch SIMEAS-Hub Begriffe 10Base-T 10Base-T spezifiziert ein CSMA/CD-Netz mit 10 Mbit/s auf TP-Leitung mit RJ-45-Stecker. Der Bus konzentriert sich bei dieser 802.3-Version in einem Hub. Alle Stationen sind mit diesem Hub sternförmig über Vierdraht-Leitungen verbunden. Es werden zwei Adernpaare der TP-Leitung verwendet: Receive und Transmit. 10Base-FL Der 10Base-FL-Standard bildet eine Erweiterung von FOIRL.
Page 25
SIMEAS-Hub Deutsch FSMA (Field Installable Subminiature Assembly) Dieser LWL-Stecker zählt zu den wenigen international standardisierten. Er ist genormt durch das Dokument IEC-SC 86B(CO)20. Bei dem FSMA-Stecker handelt es sich um einen Schraubstecker, bei dem die Faser in einer metallischen Hülle mit einem Stiftdurchmesser von 3,175 mm geführt wird, die an der Kontaktfläche plan geschliffen ist.
Page 27
SIMEAS-Hub English Contents Statement of Conformity ....................28 Hints and Warnings ......................29 General Remarks ......................31 Unpacking and Repacking ....................32 Storage ..........................32 Range of Application ......................33 Characteristics ......................... 33 Function ........................... 34 Connections ........................37 Connection Hints ......................39 Mounting ..........................
(EMC Council Directive 89/336/EEC) and concerning electrical equipment for use within specified voltage limits (Low-voltage directive 73/23 EEC). This conformity is proved by tests conducted by Siemens AG in accordance with Article 10 of the Council Directive in agreement with the generic standards EN 61000-6-4 and EN 61000-6-2 for EMC directive, and with the standard EN 61010-1 for the low-voltage directive.
SIMEAS-Hub English Hints and Warnings The warnings and notes contained in these operating instructions serve for your own safety and for an appropriate lifetime of the device. Please observe them! The following indicators and standard definitions are used: DANGER indicates that death, severe personal injury or substantial property damage will result if proper precautions are not taken.
Page 30
English SIMEAS-Hub Warning During operation of electrical equipment, certain parts of this device are subject to dangerous voltages. Severe personal injury or significant equipment damage could result from improper behaviour. Only qualified personnel should work on this equipment or in the vicinity of this equipment.
Siemens subsidiary or from our contact address (refer to page 52). Furthermore, the contents of this operating instructions are not part of an earlier or existing agreement, consent, or a legal regulation and do not represent a modification of any of these.
English SIMEAS-Hub Unpacking and Repacking When dispatched from the factory, the equipment is packed in accordance with the guide- lines laid down in IEC 60255-21. Unpack and pack them with appropriate care and without using force, using only suitable tools. Inspect the devices and verify that they are in proper mechanical condition. Note any further instructions which may be enclosed.
SIMEAS-Hub English Range of Application A SIMEAS-Hub is used to connect several segments to one another. The SIMEAS-Hub transfers each signal to the connected segments. (10Base-T/ 10Base-FL). In addition, the SIMEAS-Hub can be used for signal regeneration (repeater function). No software components are required to operate the SIMEAS-Hub. No parameterization is required.
English SIMEAS-Hub Function SIMEAS-Hub Figure 4 Block diagram of the Figure 4 shows the block diagram of the SIMEAS-Hub. The SIMEAS-Hub has six 10Base-T connections and one 10Base-FL connections. Properties: Compliant with specification IEEE 802.3 Compatible with Ethernet version 1.0 and 2.0 6 twisted-pair 10Base-T connections 1 10Base-FL fibre-optic cable connection Automatic signal retiming and regeneration...
Page 35
SIMEAS-Hub English LED for status indication of sender and receiver FO cable A link integrity test has been defined for the 10Base-FL ports. To ensure that the link is active in both directions, the 10Base-FL repeaters and the 10Base-FL terminal units send at regular intervals link integrity signals to the opposite device, in addition to the actual data signals.
Page 36
English SIMEAS-Hub A-F: Link status indicator LED (green) For each 10Base-T connection a link status LED is provided which shines when the twisted-pair cable of the port is correctly connected, the port has received a valid link and the autopartitioning of faulty network segments has been enabled. Note: If the LED does not shine, check if the twisted-pair cable is connected correctly.
SIMEAS-Hub English Connections Figure 5 Connection terminals Power supply Auxiliary voltage according to the ordering data (refer to page 47) Electrical Sync-Input LWL sender LWL receiver 10Base-T Ports E50417-K1074-C299-A1...
Page 38
English SIMEAS-Hub 8-pin RJ45 sockets Pin No Description Abbreviation Transmit + Tx + Transmit - Tx - Receive + Rx + not connected not connected Receive - Rx - not connected not connected E50417-K1074-C299-A1...
SIMEAS-Hub English Connection Hints Auxiliary Voltage Direct Cable Connection: Solid or stranded conductor with connector sleeve for conductor cross-sections from 0.5 mm to 2.5 mm , corresponding to AWG 22 to 12. The rated voltage of the connecting cables must be at least 300 V AC. Tightening Torque: min 0.5 Nm The maximum rated current of the device is 0.5 A.
English SIMEAS-Hub Mounting Warning When operating electrical devices, certain parts of these devices are subject to dangerous voltages. Therefore, noncompliance with the safe- ty notices may cause severe bodily injury or property damage. Only adequately qualified personnel may mount and connect the de- vice.
SIMEAS-Hub English Commissioning Check if the operating data correspond to the values stated on the rating plate. Do not modify the SIMEAS-Hub in any way. Snap the mounting device of the SIMEAS-Hub onto a DIN rail. Connect the 10Base-T cable to the desired RJ45 (10Base-T Ports A … F) sockets. Connect the 10Base-FL channel to the send diode and to the receive diode using the F-SMA screw-type terminals.
English SIMEAS-Hub Installation Instructions PC or PC or SIMEAS R SIMEAS R STP-Cable STP-Cable crossed SIMEAS-Hub FO-Cable FO-Cable STP-Cable SIMEAS-Hub SIMEAS-Hub STP-Cable STP-Cable STP-Cable crossed STP-Cable Simeas R STP-Cable crossed Simeas R Simeas R SIMEAS-Hub STP-Cable STP-Cable Simeas R STP: Shielded Twisted Pair Terminal: PC, SIMEAS R, SIMEAS Transceiver Hub:...
SIMEAS-Hub English Technical Data Auxiliary voltage V Rated input voltage V - DC voltage 24 … 60 V DC; 110 … 250 V DC - AC voltage 100 … 230 V AC; 45 … 65 Hz Input range - DC voltage ±20% - AC voltage ±20%...
Page 44
English SIMEAS-Hub Safety according IEC/EN 61010, part 1 (VDE 0411 part 1) Overvoltage category Pollution degree Fire resistance class of housing V0 according to UL94 Voltage test (type test) 10Base-T Ports vs. power supply U = 5.2 kV DC / 1 min Impulse voltage according to IEC 60255-5 (type test) 5 kV Voltage test (routine test)
Page 45
SIMEAS-Hub English Mechanical Tests Vibration and shock test IEC 60255-21 and IEC 60068 During operation - Vibration IEC 60255-21-1, class 2, IEC 60068-2-6 - Shock IEC 60255-21-2, class 1, IEC 60068-2-27 - Seismic vibration IEC 60255-21-3, class 1, IEC 60068-3-3 Vibration and shock test IEC 60255-21 and IEC 60068-2 During transport...
SIMEAS-Hub English Ordering Information Item Order number Short form SIMEAS-Hub – ¦ Auxiliary voltage DC 24 … 60 V DC 110 … 250 V AC 100 … 230 V; 45 … 65 Hz Maintenance, Repair and Cleaning The devices 7KE6000 do not require special maintenance. If necessary, they can be checked in a laboratory.
English SIMEAS-Hub Glossary 10Base-T 10Base-T specifies a CSMA/CD network with 10 Mbit/s based on TP cables with RJ-45 sockets. The bus is realized in this 802.3 version in a hub. All stations are connected to the hub via four wire connections. Two wire pairs are used: Receive and Transmit. 10Base-FL The 10Base-FL standard is a FOIRL extension.
Page 49
SIMEAS-Hub English FSMA (Field Installable Subminiature Assembly) This fibre optic connector is one of the few connectors internationally standardized. The norm is described in IEC-SC 86B(CO)20. The first FSMA connector was a screw drive connector with the fibre in a metallic sleeve. The diameter of the sleeve is 3.175 mm and the contact area is rubbed plane.
Page 50
English SIMEAS-Hub E50417-K1074-C299-A1...
Kontaktadresse Contact Address SIEMENS AG Power Transmission and Distribution Power Automation Postfach 4806 D-90026 Nürnberg Germany Hotline: Tel.: +49 180 524 7000 Fax: +49 180 524 2471 eMail: support@ptd.siemens.de Internet: http://www.powerquality.de Weitergabe sowie Vervielfältigung dieser Unterlage, Ver- wertung und Mitteilung ihres Inhalts nicht gestattet, soweit nicht ausdrücklich zugestanden.