Page 1
Spec.No.: MES-DG60B038A SPECIFICATIONS MANUAL INSERTION MAGNETIC CARD READER Z U – 1 8 7 0 M A 6 T 2 MATSUSHITA ELECTRIC INDUSTRIAL CO.,LTD. MATSUSHITA INDUSTRIAL EQUIPMENT CO.,LTD.
1. INTRODUCTION This specification applies to the Panasonic magnetic card reader, featuring small size, light weight and high performance. 2. COMPOSITION The magnetic card reader is composed of the mechanical portion, double circuits for reading. 1) Mechanical portion The mechanical portion is mainly composed of the following parts.
Page 4
3.3 BASIC PERFORMANCE (1) Performance ZU-1870MA6T2 ISO 7810,7811 Card standard IS01 IS02 Track used Track 1st Track 2nd Recording method Recording 210 BPI 75 BPI density Recording 79 characters 40 characters Capacity (7-bit code) (5-bit code) (2) Card operation speed : 10 cm/s to 100 cm/s (3) Magnetic head Channel Channel width : 1.4 mm...
3.5 PHYSICAL CHARACTERISTICS (1) Dimension : (W) 90 mm x (D) 119.5 mm x (H) 46 mm (2) Mass : Approx. 100 (3) Power supply : DC 5 V ± 0.5 V / Ripple(Less than 25 mA) (4) Ripple : Within 50 mV (5) Operating place : Indoor 3.6 ERROR RATE...
Page 6
5.2 OUTPUT SIGNALS The following paragraphs describe the requirements and interface signals between the user terminal and the Magnetic Card Reader shown in Figure 1. The general timing sequence for entering data from the Magnetic Card Reader to the user terminal is shown in Figure 2.
5.3 TIMING CHART Detail Chart When the jitter of the magnetic head output is 0 % , the following equation is satisfied. T=T1=T2=T3, t1=t2 2.54 cm/inch Note : T (s) = Recording density (BPI) Card speed (cm/s) 6. NOTES FOR BETTER OPERATION (1) The card should be inserted in the specified direction.
10. LIFE OF PARTS Magnetic head : 500,000 passes *Condition ·············· In a clean office room. In damp or dusty atmosphere, the life may be 1/3 to 1/5 of the above figure. 11. MAINTENANCE METHOD When replacing parts, exchange the card reader unit. 12.
Page 11
12.2 At the use (1) Be sure to use a card which conforms ISO standard. Anti-magnetic of the applied card should be 2.4x10 A/m to 2.4x10 A/m (300 Öe to 3000 Öe) of ISO standard. (2) Pulse width of the period “L” of /RCL is about 7.7µS for the card conformable to ISO1 (210 BPI specification),and about 19µS in case of ISO2(75 BPI specification).If sampling method other than falling edge sampling(such as a method detecting ”L”...