hit counter script

Ranger Tugs R-29 Sedan Owner's Manual

Hide thumbs Also See for R-29 Sedan:

Advertisement

R-29
Sedan &
Command Bridge
Owner's Manual
Quality Craftsmanship Since 1958

Advertisement

Table of Contents
loading

Summary of Contents for Ranger Tugs R-29 Sedan

  • Page 1 R-29 Sedan & Command Bridge Owner’s Manual Quality Craftsmanship Since 1958...
  • Page 2: Table Of Contents

    Port Fittings ......................7 Main Cabin Top Deck Components ............... 8 Safety is always a concern at Ranger Tugs. Please read all manuals to ensure that Stern Components ....................9 equipment is used in a safe manner. We highly recommend attendance in a Coast Main Cabin And Cockpit Lights ................
  • Page 3: Symbol Glossary

    SYMBOL GLOSSARY SPECIFICATIONS  R-29 S Attention! – Important Operating or Maintenance Instructions Length ..................28' 10" 8.79 m Length Overall (w/swim step) ............33' 4" 10.16 m Beam .................... 10' 0" 3.05 m  Draft ..................... 28" .71 m Attention! –...
  • Page 4: Equipment Location

    EQUIPMENT LOCATION PORT FIT TINGS STARBOARD FIT TINGS 1 2 3 4 5 6 7 8 9 10 11 12 13 Keep all vents, drains and exhausts clear of any obstructions to ensure proper performance of each system. Keep all vents, drains and exhausts clear of any obstructions to ensure proper performance of each system.
  • Page 5: Main Cabin Top Deck Components

    MAIN CABIN TOP DECK COMPONENTS STERN COMPONENTS 1 3 5 6 7 8 1 2 3 4 5 6 7 8 10 11 12 13 14 15 16 9 18 19 ➊ ➋ ➊ ➋ ➌ ➌ ➌ ➎ ➍ ➍...
  • Page 6: Main Cabin And Cockpit Lights

    MAIN CABIN AND COCKPIT LIGHTS FUEL SYSTEM, ENGINE, GENERATOR & WEBASTO FURNACE Volvo D4 300hp There is a secondary on-engine fuel fi lter that is not shown on this drawing. You will be able to fi nd information about this fi lter in the diesel engine manual supplied with your boat. The sec- ondary fi lter is where the water-in-fuel sensor is located.
  • Page 7: Closed Engine Cooling System

    CLOSED ENGINE COOLING SYSTEM RAW WATER / SEA STRAINER SYSTEM Provides an alternate heating system for the Fresh Water Heater and provides primary heating • Engine raw water thru-hull and strainer source for the Forced Air Cabin Heater. This system is also designed to provide cooling to the •...
  • Page 8: Fresh Water Plumbing System

    FRESH WATER PLUMBING SYSTEM SHOWER SUMP 60 Gallon Fresh Water Tank, 8 Gallon Hot Water Heater, 3.5 GPM Fresh Water Pump. 12V, 800 GPH (This should be inspected for debris on a regular basis if shower is used frequently.) The shower sump box is located underneath a removable panel in the stateroom fl oor positioned just outside the head door.
  • Page 9: Bilge Pump System

    BILGE PUMP SYSTEM WASTE SYSTEM WITH MACERATOR PUMP 12V 1100GPH 40 Gallon Tank with standard pump out, and vent The bilge pumps operate automatically with electronic fl oat switches even with battery switches Macerator pump out and breakers in the OFF position. However, the BILGE PUMP and BILGE PUMP2 will run continuously once their switches are placed in the on position.
  • Page 10: Electric Pumps Onboard

    ELEC TRIC PUMPS ONBOARD AIR CONDITIONING A/C Vent Forward A/C Unit (Under Berth) Macerator (Under Berth) Shower Sump (Under floor panel just outside of Forward A/C head door) Air Intake Grill (keep uncovered) Front A/C Control Panel A/C Vent A/C Vent Main Cabin A/C Unit (Under Helm Seat) Main Cabin A/C...
  • Page 11: Webasto Furnace

    WEBASTO FURNACE SOLAR PANEL Webasto furnace is located under access panel below refrigerator. Solar panel 160 watt, with display panel The control panel is located at the quarter berth power management center. The fuel pump is in the salon fl oor hatch compartment inside of the black box. •...
  • Page 12: Battery Configuration

    BAT TERY CONFIGURATION FUSE LOCATION & VALUES FUSE LOCATION & VALUES Dash Navigation Dash 1 Switch Panel (4 switch) Navigation 4 House Batteries, 1 Engine Battery, 1 Thruster Battery. These DC fuse blocks and windlass breaker are located behind a hinged access panel on the star- Switch Panel (8 switch) board side in the head behind the mirror.
  • Page 13: Fuse Location & Values

    FUSE LOCATION & VALUES POWER PANEL AND SOLAR PANEL CONTROLLER BOX Located in the port side cockpit lazerette These DC fuse blocks are located behind the wood hatch in the midberth. Fuses are automotive blade type and all values shown below are in Amps. Solar Panel Controller may be mounted forward of the power panel on boats with a generator Hot powered (always on) Bilge Pump #1...
  • Page 14: Ac Distribution Panel & Rotary Switch

    AC DISTRIBUTION PANEL & ROTARY SWITCH 12V HELM CONTROL OPERATION ANCHOR/ CHART WIPER WIPER WIPER BILGE BILGE HORN LIGHTS PUMP PUMP AC Distribution Panel AC Rotary Selector Switch (Available with Generator) AC Main Line 2 (with AC) Armed = Red light/audible alarm Off = Red light only.
  • Page 15: Ranger Tug R-29 Wiring Schematic (Acc. 1)

    RANGER TUG R-29 WIRING SCHEMATIC (ACC. 1) RANGER TUG R-29 WIRING SCHEMATIC (ACC. 2) R-29 Accessories #1 R-29 Accessories #2 ELECTRICAL SCHEMATIC ELECTRICAL SCHEMATIC -12V +12V -12V +12V Dash Fuse Block #1 Switched w/ House Battery Switch Dash Fuse Block #2 To Subpanel 4 Switch (Bridge) Switched w/ House Battery Switch ORG/WHT 16...
  • Page 16: Ranger Tug R-29 Wiring Schematic (Acc. 3)

    RANGER TUG R-29 WIRING SCHEMATIC (ACC. 3) RANGER TUG R-29 WIRING SCHEMATIC (LIGHTING) All Switched w/ House Battery Switch R-29 Accessories #3 R-29 Lighting -12V +12V -12V ELECTRICAL SCHEMATIC +12V ELECTRICAL SCHEMATIC Dash Fuse Block #1 RED 10 PDP Fuse Block Wipers (Port, Mid.
  • Page 17: Ranger Tug R-29 Wiring Schematic (P.d.p.)

    RANGER TUG R-29 WIRING SCHEMATIC (P.D.P.) RANGER TUG R-29 WORKING DECK R-29 Power Distribution ELECTRICAL SCHEMATIC To Generator Control Panel 6 RED 6 RED To Bridge Fuse Block To AC Panel HOUSE 2/O RED 6 RED 6 RED To Quarter Berth Fuse Block 150A SWITCH 1 RED...
  • Page 18: Mast Set Up And Takedown

    MAST SET UP AND TAKEDOWN CARE AND MAINTENANCE MAST SET UP PROCEDURE The following checklists are examples and are not all inclusive and are provided only as a guide. Please customize to your personal needs. Consult your engine and trailer user manuals for ad- 1.
  • Page 19: Example Of A Spring Pre-Launch Checklist

    EXAMPLE OF A SPRING PRE-LAUNCH CHECKLIST EXAMPLE OF WINTER STORAGE CHECKLIST CLEANING GENERAL MAINTENANCE Remove debris from scuppers and scupper drains. Fill Fuel Tank and add a fuel stabilizer. £ £ £ Clean hull using a mild biodegradable detergent and then wax. £...
  • Page 20: Warning Label Locations

    WARNING LABEL LOCATIONS NOTES...
  • Page 21 All rights reserved. Reproduction or translation by any means in whole or in part is not permitted without written authorization from Ranger Tugs. The information contained herein is correct to the best of Ranger Tugs knowledge and the contents may change without notice and without incurring obligation.

This manual is also suitable for:

R-29 command bridge

Table of Contents