hit counter script
Download Print this page

Identiv Freedom Bridge FB3 Installation Manual

Input / output

Advertisement

Quick Links

Input / Output (FB3) Freedom Bridge
Installation Guide
PART NUMBERS
PHYSICAL SPECIFICATIONS
Length
Width
Height
Weight
Max Readers
Max Input
Max Output
Certifications
BASE PLATE MOUNTING
Dimension
Millimeters
A
116.07
B
78.74
C
15.24
D
85.59
E
10.16
F
58.42
E
F
SUMMARIZED LEVELS OF
ACCESS CONTROL COMPONENTS
Destructive Attack
Line Security
Endurance
Standby Power
Single Point Locking
50-40-I/O, 50-40-I/OL
Replaces 50-40-3
76 mm (3.00 in.)
47 mm (1.85 in.)
17 mm (0.67 in.)
34 g (1.20 oz.)
0
12
2
Electrical: UL294 and UL294B
Power over ethernet: IEEE 802af
Mode A only, Class 2 (6.49 Watts)
EMI Radiation: FCC Part 15 Class B
Inches
4.57
3.10
0.60
3.37
0.40
2.30
D
C
B
A
Level I
Level I
Level I
Level I
Level I
identiv.com
sales@identiv.com
INSTALLATION REQUIREMENTS
Freedom Bridges should only be installed in dry, non-condensing
environments. The ambient temperature of the environment should
range between -40°C and 50°C.
Freedom Encryption Bridges should only be mounted to non-conductive
surfaces. Incorrect mounting may short-circuit the electronics, which will
cause it to malfunction.
DC power, reader, input contact, and output device wires should
be between 16-28 AWG. They should also be stripped 5.5mm to
sufficiently fit the terminal blocks and ensure that they do not come in
contact with each other.
INSTALLATION PROCEDURE
For each of the following steps, be sure to reference the wiring
diagram on page 2 for additional details:
1.
If you have any supervised input contacts, wire them to the Digital
Contact Inputs using Method 1 or Method 2. Note: Only In5, In6,
In11, and In12 support Input Supervision.
2.
If you have any non-supervised input contacts, wire them to the
Digital Contact Inputs.
3.
Wire the output devices to the Relay Outputs.
4.
Supply power to the Freedom Bridge using either or both of the
following methods:
A.
A 2.25 – 5.25W Power over Ethernet (PoE) port on an
Ethernet switch connected to the Freedom Bridge using
a Cat5e or Cat6 cable. (Passive injectors not supported;
Mode A PoE only)
B.
12 – 16Vdc & 350mA (300mA external & 50 mA internal)
DC power connected directly to the TB1 terminal on the
Freedom Bridge.
5.
If you are not using PoE to power your Freedom Bridge, connect
a Cat5e or Cat6 cable from any port on an Ethernet Switch to
the RJ-45 connector on the Freedom Bridge. Note: Ethernet only
supports a maximum cable length of 100 m.
6.
To configure and add the Freedom Bridge to a MESH/Freedom
Server, refer to the MESH/Freedom Solution Guide manual.
+1 888-809-8880
50-24-I/O
Replaces 50-24-3

Advertisement

loading

Summary of Contents for Identiv Freedom Bridge FB3

  • Page 1 100 m. Endurance Level I To configure and add the Freedom Bridge to a MESH/Freedom Server, refer to the MESH/Freedom Solution Guide manual. Standby Power Level I Single Point Locking Level I identiv.com sales@identiv.com +1 888-809-8880 • •...
  • Page 2 Take precautions while handling the product by using proper grounding straps at all times. NOTE Identiv (NASDAQ: INVE) is a global provider of physical security and secure identification. Identiv’s products, software, systems, and INSTALLATION GUIDE services address the markets for physical and logical access control, video analytics and a wide range of RFID-enabled applications.

This manual is also suitable for:

50-40-i/o50-40-i/ol50-24-i/o