hit counter script
Download Print this page
Panasonic ADP5100 Manual
Panasonic ADP5100 Manual

Panasonic ADP5100 Manual

Pressure sensor with built-in amplification and temperature compensation circuit ps-a pressure sensor
Hide thumbs Also See for ADP5100:

Advertisement

Quick Links

PS-A (ADP5)
ORDERING INFORMATION
Ex. ADP
5
Part No.
Terminal profile
ADP5:
1:
PS-A pressure sensor
2:
PRODUCT TYPES
Pressure inlet
hole length
Terminal
Pressure
±100kPa
–100kPa
25kPa
50kPa
100kPa
200kPa
500kPa
1,000kPa
Pressure sensor with
built-in amplification
and temperature
compensation circuit
FEATURES
1. Contains built-in amplification and
temperature compensation circuit.
Circuit design and adjustment of
characteristics are not required by
users.
2. High-level precision and high
reliability realized. (Overall accuracy is
±1.25% FS.)
3. Compact pressure sensor unit that
saves space.
Same size and footprint (7.0 mm (W) x 7.2
mm (D)) as previous PS pressure sensor.
Rated pressure
±100 kPa
DIP terminal
0:
1:
–100 kPa
2:
25 kPa
3:
50 kPa
SMD terminal
4:
100 kPa
5:
200 kPa
6:
500 kPa
7:
1,000 kPa
Part No.
3mm
DIP
DIP
terminal
terminal
ADP5100
ADP5110
ADP5120
ADP5130
ADP5140
ADP5150
ADP5160
ADP5170
Pressure inlet hole length
0: 3 mm
.118 inch
1: 5 mm
.197 inch
5mm
3mm
SMD
terminal
ADP5101
ADP5200
ADP5111
ADP5210
ADP5121
ADP5220
ADP5131
ADP5230
ADP5141
ADP5240
ADP5151
ADP5250
ADP5161
ADP5260
ADP5171
ADP5270
PS-A PRESSURE
SENSOR
(built-in amplification and
temperature compensating circuit)
Example of pressure characteristics
(ADP5140)
Drive voltage: 5V DC rated voltage;
ambient temperature: 25°C
5
4
3
2
1
0
0
50
Pressure (gauge pressure), (kPa {kgf/cm
TYPICAL APPLICATIONS
• Gas equipment: Microprocessor gas
meter, gas leakage detector
• Industrial equipment: Absorption
device, etc.
Part No.
5mm
SMD
terminal
ADP5201
ADP5211
ADP5221
ADP5231
ADP5241
ADP5251
ADP5261
ADP5271
77°F
100
2
})
Packing quantity
Inner
Outer
100
1,000
pcs.
pcs.

Advertisement

loading

Summary of Contents for Panasonic ADP5100

  • Page 1 1,000 kPa PRODUCT TYPES Part No. Part No. Packing quantity Pressure inlet hole length Terminal Inner Outer terminal terminal terminal terminal Pressure ±100kPa ADP5100 ADP5101 ADP5200 ADP5201 –100kPa ADP5110 ADP5111 ADP5210 ADP5211 25kPa ADP5120 ADP5121 ADP5220 ADP5221 50kPa ADP5130 ADP5131...
  • Page 2: Specifications

    Pressure (kPa) Temperature, °C °F Temperature, °C °F 2-(1) Output voltage 2-(2) Overall accuracy (Offset voltage) 2-(3) Overall accuracy (Rated output voltage) ADP5100 ADP5100 ADP5100 Drive voltage: 5V DC; Drive voltage: 5V DC; Drive voltage: 5V DC; temperature: 25°C 77°F temperature: 0 to 50°C...
  • Page 3 PS-A (ADP5) 3. Evaluation test Tested item Tested condition Result Temperature: Left in a 85°C 185°F constant temperature bath Storage at high temperature Passed Time: 100 hrs. Temperature: Left in a –20°C –4°F constant temperature bath Storage at low temperature Passed Time: 100 hrs.
  • Page 4 PS-A (ADP5) 2. DIP terminal (Pressure inlet hole: 5mm) ADP51*1 inch General tolerance: ±0.3 ±.012 Recommended PC board pattern (TOP VIEW 2:1) Vcc NC Vout Pressure inlet hole 2.2 dia. .087 dia. .295 .276 .283 .098 .098 GND NC dia. –0.1 .118 dia.
  • Page 5 PS-A (ADP5) 4. SMD terminal (Pressure inlet hole: 5mm) ADP52*1 inch General tolerance: ±0.3 ±.012 Recommended PC board pattern (TOP VIEW 2:1) Vcc NC Vout Pressure inlet hole .043 2.2 dia. .087 dia. .075 .276 .283 .374 GND NC .098 .098 dia.
  • Page 6 PS-A (ADP5) 4. Cleaning 5) Since this pressure sensor chip does gases, etc.) and media that contains 1) Since the pressure sensor chip is not have a water-proof construction, moisture or foreign substances will cause exposed to the atmosphere, do not allow please do not use the sensor in a location malfunction and damage.