Multi-voltage Terminal Connection Type Photoelectric Sensor
VF Series
Thank you very much for purchasing Panasonic products. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use products which
meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protec-
tion applicable in each region or country.
1
SPECIFICATIONS
Type
Thru-beam
VF-M10(T)
Item
Model No. (Note 1)
Sensing range
10m
Hysteresis
Supply voltage
Emitter: 3VA or less
Average:
Power / Current
1.5W or less
consumption
Receiver: 3VA or less
Average:
1.5W or less
Relay contact 1a
Switching capacity: 250V 1A AC (resistive load)
Output
Electrical life: 500,000 or more switching operations
Mechanical life: 100,000,000 or more switching operations
Response time
Protection
Ambient temperature
-10 to +60
(No dew condensation or icing allowed), Storage: -20 to +70
Ambient humidity
Enclosure: PBT
Material
Lens: Acrylic (front surface of retroreflective type sensor with polarizing filters: Triacetate)
Emitter:
75g approx.
Weight
Receiver:
95g approx.
MS-N70 (Sensor mounting bracket): 1 set, Gland and gland washer: 1 set
Gland packing (large / small 1 pc. each): 1 set, VF-SKG (Short-circuit metal joint): 1 pc.
RF-230 (Reflector): 1 pc. for the retroreflective type sensor
Accessories
Adjusting screwdriver: 1 pc. for the diffuse reflective type sensor and for sensors with timer functions
2 sets of sensor mounting bracket, gland, gland washer and gland
packing are attached for the thru-beam type sensors.
Notes: 1)
The model No. with suffix 'T' stands for the timer incorporated models.
The model No. with suffix 'P' shown on the label affixed to the thru-beam type sensor is
the emitter, 'D' shown on the label is the receiver.
(e.g.) Thru-beam type sensor emitter: VF-M10P, Thru-beam type sensor receiver: VF-M10D
2)
The retroreflective type sensor with polarizing filters may not stably detect specular or
glossy objects through transparent film since light is polarized by the transparent film. For
9
RETROREFLECTIVE TYPE SENSOR WITH POLARIZING FILTERS'.
details, refer to '
The sensing range for the retroreflective type sensor are specified for the RF-230 reflector.
3)
Further, the sensing range is the possible setting range for the reflector. The sensor can
detect an object less than 0.1m (VF-PRM3: 0.2m) away.
4)
The sensing range of the diffuse reflective type sensor is specified for white non-glossy
paper (200 200mm) as the object.
2
CAUTIONS
This product has been developed / produced for industrial use only.
Make sure that the power supply is off while wiring.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
In case noise generating equipment (switching regulator, inverter motor, etc.) is
used in the vicinity of this product, connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
Do not run the wires together with high-voltage lines or power lines or put them in
the same raceway. This can cause malfunction due to induction.
Take care that the sensor is not directly exposed to fluorescent lamp from a rapid-
starter lamp, a high frequency lighting device or sunlight etc., as it may affect the
sensing performance.
Do not use during the initial transient time (200ms) after the power supply is
switched on.
The cable length should be up to 100m.
When connecting the induction load for a load,
such as DC relay, the measure against surge
should be done, as shown in the figure right.
This sensor is suitable for indoor use only.
Do not use this sensor in places having excessive vapor, dust, etc., or where it
may come in contact with water, or corrosive gas.
Take care that the sensor does not come in contact with water, oil, grease, organ-
ic solvents, such as, thinner etc., or strong acid, and alkaline.
The following items are required, as conditions for use in order to conform to CE Marking.
The output applied voltage should be the same as the supply voltage of the sensor.
Be sure to add a short-circuit protection (a fuse or a breaker) to the power sup-
ply input and the output.
INSTRUCTION MANUAL
WARNING
Retroreflective
Diffuse reflective
With polarizing
filters (Note 2)
VF-RM5 T
VF-PRM3
VF-D500(T) VF-D1000(T)
0.1 to 5m
0.2 to 3m
500mm
(Note 3)
(Note 3)
(Note 4)
15% or less of operation distance
+10
+10
24 to 240V AC
% or 12 to 240V DC
-15
-15
3VA or less
(Average: 1.5W or less)
30V 2A DC (resistive load)
(switching frequency 3,600 operations/hour)
(switching frequency 36,000 operations/hour)
20ms or less
IP66 (IEC)
35 to 85% RH, Storage: 35 to 85% RH
95g approx.
DC relay
Sensor
output
3
MOUNTING
The tightening torque should be
0.78N m or less.
4
I/O CIRCUIT DIAGRAMS
Output relay
Internal circuit
1m
5
WIRING
(Note 4)
%
Prepare the cable end as shown below.
To maintain a watertight performance, the cable should have an outer diameter
between
be securely tightened, however, the tightening torque of the screw should be of
0.96 to 1.44N m.
Cable
Outer dia:
Conductor cross section area:
0.25 to 0.75mm
Check the terminal No. first and
connect from the terminal No.
However, the tightening torque of
the screw should be of 0.48N m or
less.
Fix the cover with the mounting
screw.
However, the tightening torque of the screw should be of 0.48 to 0.76N m.
Dimensions of the suitable crimp terminals
3.6 or more
7
or less
Note: Use crimp terminals with insulating sleeves.
Recommended crimp terminal: Nominal size 1.25 3.5
6
MOUNTING THE SHORT-CIRCUIT METAL
JOINT (VF-SKG)
If the sensor and the load are supplied power from the same power supply, the
number of wires can be reduced by one by using the enclosed short-circuit metal
joint.
Connection example
Output relay
+
DC
power
-
How to mount
Loosen the screws on terminals
Mount the short-circuit metal joint VF-SKG on the
terminals as shown on the right.
Terminal No.
Power supply
Multi-
+10
24 to 240V AC
%
-15
voltage
or
circuit
+10
12 to 240V DC
%
-15
Relay contact
(1a)
Note: The emitter of the thru-beam type sensor
6 to
10mm with a smooth covering material that allows the gland to
80mm
}
Output
}
Power
supply
65mm
Gland
Gland washer
6 to
10mm
2
.
Round type
3.6 or more
10 or less
7
7
or less
or less
19 or less
(After crimping)
Terminal No.
Multi-
voltage
Power supply
circuit
Short-circuited by the short-
circuit metal joint (VF-SKG)
and
.
Sensor mounting bracket
MS-N70
(Accessory)
has only two terminals for power supply
(terminal No.
and
).
Gland packing (2 Nos. enclosed)
Small hole: For
6 to
8mm cable
Large hole: For
8 to
10mm cable
Terminal No.
(Unit: mm)
Y-shaped type
10 or less
7
or less
19 or less
(After crimping)
Load
Short-circuit
metal joint

Advertisement

loading

Summary of Contents for Panasonic VF Series

  • Page 1 Sensor mounting bracket MS-N70 (Accessory) Thank you very much for purchasing Panasonic products. Please read this Instruction Manual carefully and thoroughly for the correct and optimum use of this product. I/O CIRCUIT DIAGRAMS Kindly keep this manual in a convenient place for quick reference.
  • Page 2 Phone: +81-568-33-7861 FAX: +81-568-33-8591 Europe Headquarter: Panasonic Electric Works Europe AG Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany Phone: +49-8024-648-0 US Headquarter: Panasonic Electric Works Corporation of America 629 Central Avenue New Providence, New Jersey 07974 USA Phone: +1-908-464-3550 PRINTED IN CHINA...

This manual is also suitable for:

Vf-m10Vf-rm5Vf-prm3Vf-d500Vf-d1000Vf-m10t ... Show all