PRESENTATION OF THE APPLIANCE Lacunza congratulates you on your choice. Certified under ISO 9001, Lacunza guarantees the quality of its appliances and undertakes to meet the needs of its customers. Confident of the know-how afforded by more than 50 years’ experience, Lacunza uses advanced technologies in the design and manufacture of its entire range of appliances.
Page 3
PRESENTATION OF THE APPLIANCE 4.1.3. Flue socket ................................18 4.1.4. Painted sheet-steel-cast-iron parts........................18 4.1.5. Firebox glass ................................18 4.2. Maintenance of the chimney flue ......................18 4.3. Important advice ............................18 TROUBLESHOOTING .......................... 19 BASIC BREAKDOWNS ........................20 DECLARATION OF PERFORMANCE ....................
P ≤ 10kW fixtures, etc.). 10 < P ≤ 15 Lacunza’s liability is limited to the 15 < P ≤ 20 supply of the material and does not include 20 < P ≤ 25 installation of the appliance.
• Make sure that the flueway is not Distance to obstructed with packing or loose parts. combustible Atlantic 500 • Make sure that the airtight joints materials (mm) on the flue circuit are in perfect From the right-hand side condition.
INSTRUCTIONS FOR THE INSTALLER the joint with fire sealant or fire cement to The flue must be clean and airtight over make it completely airtight. its entire length. The installer must ensure that the pipe The flue must be at least 6m tall and the connected to the appliance is well secured chimney cap must not hinder the free and there is no chance of it coming free...
INSTRUCTIONS FOR THE INSTALLER Figure No.6 - Distances between the chimney crown and objects within a 10m radius The chimney crown must clear any neighbouring building or obstacle located within a radius of 10m to 20m from the chimney outlet. Figure No.7 - Distances between the chimney crown and objects within a radius Figure No.5 - Distances between chimney...
Page 12
If sufficient updraught is not achieved by correcting the flue installation, Lacunza supplies an accessory for exceptional cases: a part which seals the top of the front part of the appliance and helps prevent smoke escaping into the room.
INSTRUCTIONS OF USE appliance to wear out more quickly INSTRUCTIONS OF USE than normal. • Resinous wood may mean that the The manufacturer accepts no liability appliance and the flue need to be whatsoever for damage caused to parts as cleaned more often.
INSTRUCTIONS OF USE 3.2. Description of the parts of the appliance 3.2.1. Operating components Figure No.10 - Operating components on the appliance • A: Firebox door handle • B: Primary air intake B1 open (right) B2 closed (left) • C: Secondary and double-combustion air intake C1 open (right) C2 closed (left) Certain weather conditions, such as fog,...
INSTRUCTIONS OF USE • Open the firebox door(s) and open The maximum load height is 2 logs with diameters of approx. 10 cm. all the firebox air-intake inlets to the full. The minimum interval between loads • Place paper or a firelighter and for nominal heat output is 60 minutes.
INSTRUCTIONS OF USE burned in the first combustion. This towards the front of the appliance to increases the performance of the appliance release it from the vermiculite parts. and reduces emissions. Ocean models, double- combustion air intake is the same as the secondary-air intake (both air intakes are controlled through the same inlet at the same time).
Page 17
INSTRUCTIONS OF USE The vermiculite deflectors can then be extracted as shown: Figure No.14 - Extracting the vermiculite deflectors Changing the position of the Ocean stainless-steel reinforcement The stainless-steel reinforcement has an open and closed position. When it is closed, a lot of combustion gas is retained, meaning that the flue and the fuel used must be in optimum conditions in order to ensure correct operation.
Page 18
INSTRUCTIONS OF USE Fitting the circular part on the flue socket A circular part is supplied inside the appliance. This part must be fitted in position inside the flue in order to achieve all the values in the UNE-EN 12815, UNE- EN 13229, UNE-EN 13240 standard.
4.1.4. Painted sheet-steel-cast-iron parts. used. These parts should be cleaned with a Lacunza accepts no liability for any brush or dry cloth. Do not dampen the modification to the product which it has parts: the steel could rust and the paint not authorised.
TROUBLESHOOTING TROUBLESHOOTING This symbol means that a qualified professional should be called to perform the operation. Problem Probable causes Solution Use hard woods, cut at least 2 years ago and stored in a Green or damp wood sheltered, ventilated place Use crumpled paper or firelighters and dry wood chips to light The logs are too large the fire.