hit counter script

Advertisement

HONEYWELL EXCEL 5000 OPEN SYSTEM
Overview of Hardware.................................................................................................................................................................. 2
Terminal Blocks ....................................................................................................................................................... 3
LonWorks Interface.................................................................................................................................................. 3
Ethernet Interface .................................................................................................................................................... 3
RS232C Serial Interface Ports ................................................................................................................................. 3
CF Port LED, Request Button, and Slot ................................................................................................................... 4
USB Interface Downloads ........................................................................................................................................ 4
LEDs and Buttons .................................................................................................................................................... 4
Power Supply LED ................................................................................................................................................... 4
Binary Input (terminals 3+4) LED ............................................................................................................................. 4
Binary Output (terminals 7+8) LED .......................................................................................................................... 5
Binary Output (terminals 9+10) LED ........................................................................................................................ 5
Ethernet LEDs.......................................................................................................................................................... 5
LED's L1 and L2....................................................................................................................................................... 5
Reset Button ............................................................................................................................................................ 5
Mounting ....................................................................................................................................................................................... 5
Before Installation .................................................................................................................................................... 5
Dimensions .............................................................................................................................................................. 5
Power Supply................................................................................................................................................................................ 6
Wiring....................................................................................................................................................................... 6
Transformer Data..................................................................................................................................................... 7
Lightning Protection ................................................................................................................................................. 7
RIN-APU24 .............................................................................................................................................................. 7
LonWorks Communications........................................................................................................................................................ 7
General Information ................................................................................................................................................. 7
Binary Input and Outputs ............................................................................................................................................................ 8
Wiring....................................................................................................................................................................... 8
Binary Input.............................................................................................................................................................. 8
Binary Outputs ......................................................................................................................................................... 8
Engineering, Commissioning...................................................................................................................................................... 8
Required Preparations ............................................................................................................................................. 9
Engineering, Downloading, and Commissioning Procedure..................................................................................... 9
Protocolling ............................................................................................................................................................ 10
Updating Firmware................................................................................................................................................. 10
® U.S. Registered Trademark
Copyright © 2006 Honeywell Inc.
All Rights Reserved

TABLE OF CONTENTS

Network .................................................................................................................... 7
Excel Web
XL1000A/B
INSTALLATION INSTRUCTIONS
EN1B-0256GE51 R0506C

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell Excel Web XL1000A

  • Page 1: Table Of Contents

    Excel Web XL1000A/B HONEYWELL EXCEL 5000 OPEN SYSTEM INSTALLATION INSTRUCTIONS TABLE OF CONTENTS Overview of Hardware.................................. 2 Terminal Blocks ............................... 3 LonWorks Interface..............................3 Ethernet Interface ..............................3 RS232C Serial Interface Ports ..........................3 CF Port LED, Request Button, and Slot ........................4 USB Interface Downloads ............................
  • Page 2: Overview Of Hardware

    EXCEL WEB CONTROLLER – INSTALLATION INSTRUCTIONS OVERVIEW OF HARDWARE binary output (terminals 9+10) LED (yellow) binary output (terminals 7+8) LED (red) (LED = application has closed contact) (LED = watchdog has closed contact) power supply LED (green) LED2 (currently unused) (LED = power supplied) binary input (terminals 3+4) LED (yellow)
  • Page 3: Terminal Blocks

    EXCEL WEB CONTROLLER – INSTALLATION INSTRUCTIONS • Terminal Blocks via terminals 5+6 and 11+12 of the terminal blocks (see Fig. 1 on page 2); and/or The Excel Web features two rows of removable terminal • via the corresponding jack located to the right of the blocks (located at the front left-hand side;...
  • Page 4: Cf Port Led, Request Button, And Slot

    EXCEL WEB CONTROLLER – INSTALLATION INSTRUCTIONS Port 2 (Browser Interface) NOTE: Before removing a CF card, always first push the CF request button and wait (usually just a few Port 2 is intended for the connection (as needed, or per- seconds) until the CF LED turns OFF.
  • Page 5: Binary Output (Terminals 7+8) Led

    In case of a problem, check if the L service LED's ORKS behavior is changed by resetting the Excel Web controller using the reset button. Please contact Honeywell if this does not solve the problem. 220 +/- 0.3 5 +/- 0.3 Ethernet LEDs Fig.
  • Page 6: Power Supply

    EXCEL WEB CONTROLLER – INSTALLATION INSTRUCTIONS Its housing conforms to IP20. Its pollution degree (2) makes it suitable for use in residential controls, commercial controls, in a clean environment, or non-safety controls for installation on or in appliances. step The Excel Web is suitable for mounting on a standard rail (DIN EN 50022-35 x 7,5), on walls or in panels, as well as for installation in appropriately-sized wiring cabinets or fuse boxes.
  • Page 7: Transformer Data

    (see also Fig. 12). Fig. 12. Connection of Excel Web Table 3. Cable sizing (use only copper cables) Lightning Protection cross-sectional area Please contact your local Honeywell representative for type of signal ≤ 300 ft ≤ 550 ft ≤ 1300 ft information on lightning protection.
  • Page 8: Binary Input And Outputs

    Two wires with a total thickness of 14 AWG can be twisted together and connected using a wire nut (include a pigtail When possible, use Honeywell AK3781, AK3782, AK3791, with this wire group and attach the pigtail to the individual or AK3792 cable (US part numbers).
  • Page 9: Required Preparations

    EXCEL WEB CONTROLLER – INSTALLATION INSTRUCTIONS Required Preparations Engineering, Downloading, and In order to access (with a laptop or PC) the Excel Web via Commissioning Procedure Ethernet/IP for the first time, you may employ any one of 1. The user must first create (on a Windows-compatible the following three options: platform, using CARE 7.0) the application data for the Excel Web controller.
  • Page 10: Protocolling

    Excel Web, this can be done either via USB or Ethernet. Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, Ecublens, Route du Bois 37, Switzerland by its Authorized Representative: Automation and Control Solutions Honeywell GmbH Böblinger Straβe 17...

This manual is also suitable for:

Excel 5000 open systemExcel web xl1000b

Table of Contents