hit counter script
GE MDS Setup Manual
GE MDS Setup Manual

GE MDS Setup Manual

Orbit managed connected router (mcr)
Hide thumbs Also See for MDS:

Advertisement

1.0
INTRODUCTION
This guide provides installation and startup instructions for the MDS
Orbit Managed Connected Router (MCR) shown Figure 1. The
MCR is a highly secure, industrial wireless solution for broad based
applications, including control center monitoring, well site pad
operations and video surveillance.
The unit provides wireless communication via multiple technologies
in a single, industrial package, without the need for additional
modules or add-ons. In addition, wired serial, Ethernet and USB
interfaces are provided at the front panel, reducing network cost
and complexity. Depending on order entry options the unit may be
equipped with a combination of Cell, Wi-Fi, and 900 MHz
unlicensed FHSS/DTS radio.
Units are offered in two different interface offerings; 2 Ethernet/1
Serial (2E1S), or 2 Serial/1 Ethernet (2S1E). The 2E1S configura-
tion is the standard model and is shown here, although most in-
formation applies equally to both configurations.
Figure 1: MCR Sample Unit, Showing Connectors & Indicators
1.1
Technical Manual
This Setup Guide covers basic installation and startup instructions
for the unit. A more detailed Technical Manual is also available
(05-6632A01). Refer to the Technical Manual for important warn-
ings, cautions and notes. GE MDS manuals, Setup guides, Firm-
ware, drivers and Application Notes are available free of charge at
www.gemds.com.
GE MDS has produced a series of instructional videos for config-
uration and setup of the Orbit MCR products on YouTube. These
are available free of charge at:
2.0
INSTALLATIONS
2.1
Main Requirements
WARNING: When the unit is to be installed in hazardous
locations, use only the serial or Ethernet connections on the unit's
front panel. Do not use the USB port in hazardous locations.
Figure 2 shows a typical installation of the unit. There are three
main requirements for installation:
• Adequate and stable primary power (10-60 VDC).
• Efficient and properly installed antennas for configured op-
tions.
05-6709A02, Rev. A
http://tinyurl.com/pey2ull
GE MDS MCR Setup Guide - Brazil
• Correct interface connections between the unit and associ-
ated data equipment.
2.2

Installation Steps

Installation details for the product may vary, depending on
site-specific factors. The steps here provide the basic tasks needed
at most sites.
1. Mount the unit. Attach the supplied brackets to the bottom of
the case (if not already attached), using the screws provided.
Mounting bracket dimensions are shown in Figure 2. If DIN Rail
mounting brackets are to be used, consult the Technical
Manual for details.
NOTE: To prevent moisture from entering the unit, do not
mount the case with the cable connectors pointing up. Also, dress
all cables to prevent moisture from running along the cables and
into the enclosure.
Figure 2: Typical MCR Installation
Figure 3: Mounting Bracket Dimensions
2.
Install the antennas and feedlines. The antennas used must
be designed to operate in the appropriate frequency band and
be mounted in a location providing a clear path to the associ-
GE MDS MCR
Setup Guide - Brazil
1

Advertisement

Table of Contents
loading

Summary of Contents for GE MDS

  • Page 1: Installation Steps

    Application Notes are available free of charge at www.gemds.com. Figure 2: Typical MCR Installation GE MDS has produced a series of instructional videos for config- uration and setup of the Orbit MCR products on YouTube. These are available free of charge at: http://tinyurl.com/pey2ull...
  • Page 2: Unit Configuration

    HyperTerminal or a similar supported by a suitable service plan. communications program. The following parameters must be used: 115200 bps, 8 bits, no parity, one stop bit (8N1), flow control disabled, VT100 emulation. GE MDS MCR Setup Guide - Brazil 05-6709A02, Rev. A...
  • Page 3: Lte, Hspa+,Gsm/Gprs (Emea/Apac)

    % show details command. band. Similar to the older MDS iNET-II 900 transceivers, it supports Tab-completion is a useful feature that presents CLI users connection of Ethernet and/or Serial devices in the field in a Point-to-Multipoint or Point-to-Point wireless network topology.
  • Page 4: Led Functions

    NOTE: The unit is hardwired as a DCE device For proper operation, all units must meet the basic requirements which follow. Check these items first when troubleshooting: • Adequate and stable primary power GE MDS MCR Setup Guide - Brazil 05-6709A02, Rev. A...
  • Page 5 When installed in hazardous locations, please contact GE MDS, using the information at the back of this guide. use only the serial and Ethernet In addition, manual updates can be found on our web site at connections on the unit’s front panel.
  • Page 6 SPECIAL INFORMATION FOR BRAZIL —GE MDS MCR Applicability For Brazil, the equipment model GE MDS MCR will be provided only with the settings described below in Table 1, Table 2 and Table 3, below Additionally, the unit will not be provided with antennas.

Table of Contents