hit counter script
Download Print this page

Water Specialties TR15 Operation And Maintenance Manual

Totalizer-transmitter, indicator-totalizer transmitter, propeller meter

Advertisement

TOTALIZER-TRANSMITTER
INDICATOR-TOTALIZER
TRANSMITTER
OPERATION AND MAINTENANCE MANUAL
*P/C CARD MOUNTED OPTIC SWITCH
HEMET, CALIFORNIA 92545 U.S.A.
VISIT OUR WEBSITE:
MODEL TR15
MODEL TR16

PARTS LIST

FEATURING:
*SOLID STATE CONSTRUCTION
*CURRENT OUTPUT SIGNAL
*CUB TYPE ACTUATOR
*SEALED HOUSING OUTPUT SIGNAL
*CUP TYPE ACTUATOR
*SEALED HOUSING
3255 WEST STETSON AVENUE
PHONE:
951-652-6811
FAX:
951-652-3078
www.mccrometer.com
30119-33 Rev. 1.8/04-14

Advertisement

loading

Summary of Contents for Water Specialties TR15

  • Page 1: Parts List

    30119-33 Rev. 1.8/04-14 TOTALIZER-TRANSMITTER MODEL TR15 INDICATOR-TOTALIZER TRANSMITTER MODEL TR16 OPERATION AND MAINTENANCE MANUAL PARTS LIST FEATURING: *P/C CARD MOUNTED OPTIC SWITCH *SOLID STATE CONSTRUCTION *CURRENT OUTPUT SIGNAL *CUB TYPE ACTUATOR *SEALED HOUSING OUTPUT SIGNAL *CUP TYPE ACTUATOR *SEALED HOUSING 3255 WEST STETSON AVENUE HEMET, CALIFORNIA 92545 U.S.A.
  • Page 2 30119-33 Rev. 1.8/04-14 WARRANTY This Warranty shall apply to and be limited to the original purchaser consumer of any McCrometer product. Meters or instruments defective because of faulty material or workmanship will be repaired or replaced, at the option of McCrometer, free of charge, FOB the factory in Hemet, California, within a period of one (1) year from the date of delivery.
  • Page 3: Table Of Contents

    8. Adapter Plate 9. Transmitter Drive Clevis DESCRIPTION 10. Transmitter Base O-Ring 11. Position of Transmitter MODEL TR15 TOTALIZER-TRANSMITTERS provide a totalization 12. Transmitter Wiring of flow volume and pulse output. V. SERVICE MANUAL MODEL TR16 INDICATOR-TOTALIZER TRANSMITTERS provide an instantaneous flow rate indication and totalization of flow VI.
  • Page 4: Remove

    Proper paper work or damaged. Install the vertical shaft collar and bearing must be enclosed with any returned material. assembly on the new (3/16” diameter tip) vertical shaft, The shipping carton contains the following items: Model TR15 or TR16 ..............1 Base O-Ring...
  • Page 5: Totalizer Drive Magnet

    30119-33 Rev. 1.8/04-14 MCCROMETER products have been carefully designed to be as main- but do not tighten the collar bearing set screw yet. Insert the vertical shaft assembly, plastic tip first, into the meter head and rotate the tenance free as possible. Periodic preventive maintenance, however, shaft gently until it is engaged in the driven miter gear shaft of the is highly recommended and should be practiced according to schedule miter gear frame assembly.
  • Page 6 30119-33 Rev. 1.8/04-14 ‡1. BONNET MOUNTING SCREWS (#2) located beneath the four screws (#3). indicator-totalizer bonnet lid, should be removed and the entire bon- net (#1) lifted off of the transmitter. Replace the o-ring seals around ‡4. CHANGE GEARS (#8 & #9) should be checked again to make each of the four screws (#3) and at the bottom of the bonnet (#4) and certain they are in proper alignment (see section VIII-3).
  • Page 7: Vertical Shaft

    30119-33 Rev. 1.8/04-14 If the meter totalizer or indicator-totalizer does work but the turn when the driven clevis shaft (#28) turns, then the transmitter remote instrument does not operate (not receiving proper signal), gear train is damaged and must be returned to the factory for repair then use troubleshooting procedures #2 thru #4 and #8 thru #11.
  • Page 8 Be sure to route the communication lines connected to the terminal strip away from the totalizer drive magnet (#9) or indicator Standard Model TR15 & TR16 current transmit- A-drive gear (#8). These rotating parts within the transmitter can ters have an output of 4-20 mA at maximum scale of the damage the wires.
  • Page 9 Model TR15 & TR16 current output (4-20 mA). line. Communications lines should be kept from tangling up in high Because 4 mA equals ZERO it must be subtracted from voltage lines inside the panel or wiring cabinet.
  • Page 10 > 12 VDC able responses. Potential noise sources: Relay coils, solenoids, AC power wires, current carrying cables, or radio frequency transmis- sions. NOTES TR15/16 BOARD GREEN 0.400 MULTIMETER 2 WIRE CIRCUIT CONNECTION...
  • Page 11 30119-33 Rev. 1.8/04-14 PROCEDURES FOR CHECKING INOPERATIVE INSTRUMENT SYSTEMS WITH mA AND PULSE OUTPUT TRANSMITTERS TESTING TRANSMITTER PULSE OUTPUT AND INSTRUMENT POWER SUPPLY TR15/TR16 TRANSMITTER (150 PPM AND 600 PPM PULSE OUTPUT) WIRED TO A MODEL IN62 BLACK INPUT RESET INPUT...
  • Page 12 30119-33 Rev. 1.8/04-14 PROCEDURES FOR CHECKING INOPERATIVE INSTRUMENT SYSTEMS HAVING A TRANSMITTER WITH 4-20 mA TESTING TRANSMITTER OUTPUT AND POWER SUPPLY VOLTAGE TR15/TR16 TRANSMITTER (4-20 mA OUTPUT) WIRED TO A MODEL IN41 10” CHART RECORDER MAIN PCB IN36-1 (24 V) POWER SUPPLY...
  • Page 13 30119-33 Rev. 1.8/04-14 WIRING DIAGRAM FOR TR15/16 TO IN41 TR15/TR16 TRANSMITTER (4-20 mA OUTPUT) WIRED TO A MODEL IN41 10” CHART RECORDER IN36-1 RECORDER POWER SUPPLY MAIN PCB OUTPUT INPUT TB-2 24 VDC 115 VAC 115 VAC WHITE BLACK TERM.
  • Page 14 30119-33 Rev. 1.8/04-14 MODEL TR15 and TR16 TRANSMITTER SOLID STATE CONSTRUCTION CURRENT OUTPUT - PULSE RATE OUTPUT (TWO) 2-WIRE CIRCUITS 2 WIRE CIRCUIT CONNECTION (STANDARD TRANSMITTER SUPPLIED WITHOUT PULSE OUTPUT) (AVAILABLE SEPARATELY) MODEL IN36-1 POWER SUPPLY 115 VAC 60 Hz...
  • Page 15 30119-33 Rev. 1.8/04-14 NOTES...
  • Page 16 30119-33 Rev. 1.8/04-14 TOTALIZER-TRANSMITTER MODEL TR15 PARTS LIST Part Number Description none 7-TR15-150/600 Model TR15 Totalizer Transmitter (Specify Pulse Rate) none 6-4260 Totalizer & Bonnet Complete (Items 1 thru 6) none 7-4260 Totalizer & Bonnet Complete (Items 1 thru 8) 5-4316...
  • Page 17 30119-33 Rev. 1.8/04-14 TOTALIZER-TRANSMITTER MODEL TR15...
  • Page 18: Bonnet Mounting Screws

    30119-33 Rev. 1.8/04-14 INDICATOR-TOTALIZER-TRANSMITTER MODEL TR16 PARTS LIST Description Part Number none 7-TR16-150/600 Model TR15 Totalizer Transmitter (Specify Pulse Rate) none 5-4337 Indicator Totalizer Bonnet Assembly none 1-4338 Indicator Totalizer Bonnet Lid with Pin 1-1115-10-56H Screw, Bonnet Mounting 1-1551-6 Screw, Bonnet Mounting O-ring...
  • Page 19: Totalizer

    30119-33 Rev. 1.8/04-14 INDICATOR-TOTALIZER-TRANSMITTER MODEL TR16...
  • Page 20: Gears

    30119-33 Rev. 1.8/04-14 REPAIR RECORD PURCHASE DATE SERIAL NUMBER SPECIFICATIONS INDEX ODOMETER READING METER SIZE & MODEL NO. CHANGE GEARS REGISTRATION INDICATOR DIAL GEARING RATIO NOTES: DATE REPAIR METER LOCATION COMMENTS...

This manual is also suitable for:

Tr16