hit counter script

Error And Warning Conditions Reported By The Control Unit - Honeywell QUIETPRO QP100Ex User Manual

Hide thumbs Also See for QUIETPRO QP100Ex:
Table of Contents

Advertisement

13 Error and Warning Conditions Reported by the Control Unit

The table below shows error and warning conditions that will be reported by the control unit when appropriate.
Available voice feedback messages may vary dependent on the configuration of the unit.
Problem
Voice feedback
Fit test failed
"Poor fit left/right/both ear(s)"
followed by warning signal
(repeated until warning
acknowledged by user)
Dose exceeding
"Dose level too high"
upper limit
followed by wobble tone
(repeated until warning
acknowledged by user)
Battery level
"Battery level very low"
very low
Automatic
"System shutdown
shutdown
Press any button to stop
shutdown."
"Cable not detected"
Radio cable
not detected
when connecting
the cable
Headset failure
"Problem detected.
Check headset."
HONEYWELL SAFETY PRODUCTS
Indicator lights
Red blinking during
voice message
Continous red blinking
until acknowledged
Red blinking during
voice message
Red blinking during
voice message
N/A
N/A
Recommended action
Re-fit the eartip(s)
Work in a quiet area for
the remainder of the work
shift
Charge battery
Press any button to stop
shutdown. This feature
can be disabled if desired
The cable memory chip
is present, but not
compatible with the unit.
Replace cable.
Headset might have
breakages. Ear tips may
have failures. Having the
control unit turned on
without the ear tips being
inserted in the ears or
touching the outside of
the ear tips repeatedly
with the control unit
turned on might cause a
false alarm. Replace ear
tips. If warning still
appears; check headset
and replace if it is found
to be faulty.
21

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents