Device designs
3.4.2
Name plate for model with integral mount design (single-compartment housing)
„A"
„C"
Fig. 2
„A" Name plate
1 Model number (for more detailed information about
the technical design, refer to the data sheet or the
order confirmation)
2 Order no.
3 Meter size and nominal pressure rating
4 Tmed = maximum permissible fluid temperature
Tamb = maximum permissible ambient temperature
5 Protection type according to EN 60529
6 Calibration value Qmax DN
7 Communications protocol of transmitter
8 Software version
9 CE mark
10 Client-specific TAG number (if specified)
11 Material: Flange/lining/electrode
12 Excitation frequency of sensor coils
13 Supplementary information: EE = grounding
electrodes, TFE = partial filling electrode
14 Calibration value Ss (span)
Calibration value Sz (zero point)
Accuracy to which the unit was calibrated
(e.g., 0.4% of rate)
„B" Ex mark according to FM and cFM (example)
IMPORTANT (NOTE)
Meters with 3A approval are labeled with an additional plate.
12 - EN
„A"
1
2
3
4
5
6
7
„B"
8
„B"
„C"
FEX300, FEX500
15Supply voltage
16 Year of manufacture
17 Label indicating whether the unit is subject to the
Pressure Equipment Directive (PED).
Information on the relevant fluid group.
Fluid group 1 = hazardous fluids, liquid, gaseous.
(Pressure Equipment Directive = PED).
If the pressure equipment is not subject to the
Pressure Equipment Directive 2014/68/EU, it is
classified in accordance with SEP (= sound
engineering practice) as per Art. 3 Para. 3 of the
PED.
If no such information is present, it means that the
device does not claim to comply with the
requirements of the Pressure Equipment Directive
2014/68/EU. Water supplies and connected
equipment accessories are classed as an exception
in accordance with guideline 1/16 of Art. 1 Para. 3.2
of the Pressure Equipment Directive.
„C" Safety mark
SM/FEX300/FEX500/FM/CSA-EN
9
10
11
12
13
14
15
16
17
G01333