hit counter script

Cisco ASR 1013 Hardware Installation Manual page 341

Asr 1000 series
Hide thumbs Also See for ASR 1013:
Table of Contents

Advertisement

Cisco ASR 1002-F Router Overview and Installation
Before performing any of the following procedures, ensure that power is removed from the DC circuit.
Danger
Statement 1003
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Warning
Statement 1030
This section provides the procedures for connecting AC-input and DC input power to your Cisco ASR 1002-F
Router.
The DC power supply for the Cisco ASR 1006, Cisco ASR 1004, Cisco ASR 1002, and Cisco ASR 1002-F
routers operate at individual specifications. The following table shows the common input ranges and circuit
breaker requirements.
Table 68: Cisco ASR 1000 Series Router DC Power Supply System Input Requirements
Cisco ASR 1000
Series Router
DC Power
Supply
Cisco ASR 1006
Cisco ASR 1004
Cisco ASR 1002
and Cisco ASR
1002-F 1
1 The Cisco
ASR 1002-F
Router DC
power supply,
with 16 A input
rating must use
an AWG #12
gauge wire for a
20 A circuit
breaker and an
AWG #10 gauge
wire for a 30 A
circuit breaker.
System Input
Circuit Breaker
Rating (Amps)
Amps
Minimum
40
Always 50
24
30
16
20
Connecting Power to the Cisco ASR 1002-F Router
AWG # Wire
Maximum
Minimum
Always AWG
#6 wire
40
10
30
12
Cisco ASR 1000 Series Router Hardware Installation Guide
Maximum
8
10
307