hit counter script

Cd Mechanism Section; Fitting Of Dial Pointer - Sharp GX-CD30 Service Manual

Hide thumbs Also See for GX-CD30:
Table of Contents

Advertisement

CD MECHANISM SECTION

Perform steps 1, 2, 9 and 10 of the disassembly method to
remove the CD mechanism.
How to remove the pickup (See Fig. 7-1.)
1. Remove the hooks (F1) x 4 pcs., to remove the CD cover.
2. Remove the screws (F2) x 2 pcs., to remove the shaft (F3)
x1 pc.
3. Remove the stop washer (F4) x1 pc., to remove the gear
(F5) x 1 pc.
4. Remove the pickup.
1. Remove the three screws, and remove the tuner PWB from the tuner frame. (See Fig. 7-2)
2. Turn fully the dial wheel in the  direction. (See Fig. 7-3)
3. Set the dial pointer as shown in Figure 7-2, and mount the tuner PWB.
Tuner
Frame
Downloaded from
www.Manualslib.com

FITTING OF DIAL POINTER

"0" Point
Dial
Pointer
( 229 )
Figure 7-2
manuals search engine
CD Cover
( F1 ) x2
Screw x3
Tuner PWB
(Top view)
– 7 –
GX-CD30/30C/130/130C
( F1 ) x2
( F2 ) x2
ø2.6 x6mm
CD Mechanism
Shaft
( F3 ) x1
Gear
( F5 ) x1
Stop Washer
( F4 ) x1
Pickup
Figure 7-1
Tuner PWB
(Bottom view)
A
Figure 7-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gx-cd30cGx-cd130cGx-cd130

Table of Contents