AND SERVICE MANUAL 
Congratulations on purchasing your new Lancaster Reverse Osmosis System. This 
unit is designed to give you many years of trouble free service. When installed in 
accordance with the following instructions and if given reasonable care, better water 
quality will be the result. For servicing and future inspection purposes, please file this 
booklet with your important documents.

Advertisement

Table of Contents
loading

Summary of Contents for Lancaster 7-TFC-50

  • Page 1 7­TFC­50  INSTALLATION, OPERATING  AND SERVICE MANUAL  Congratulations on purchasing your new Lancaster Reverse Osmosis System. This  unit is designed to give you many years of trouble free service. When installed in  accordance with the following instructions and if given reasonable care, better water  quality will be the result. For servicing and future inspection purposes, please file this  booklet with your important documents.
  • Page 2 INSTALLATION INSTRUCTIONS  1)   Place the filters in the unit. (Some units come with the filters installed, others have a bag with the  filters in them.) The white sediment and carbon filter should be put in the vertical 10” housing. The  membrane should be placed in the horizontal housing with the O­rings inserted first.  2)   Locate cold water line under the sink.  3)   Assemble saddle valve on cold water line. Turn the pipe clamp adjustment plate to fit the contour of  the pipe. Tighten the bolt so the saddle valve is attached firmly to the pipe.  4)  Drain saddle.  Clamp drain saddle securely, approximately 6 inches above P­trap.  Drill a hole through  one wall of pipe at opening of saddle valve.  5)   Faucet hole in sink. The faucet must be positioned with aesthetics, function and convenience in mind.  Ample flat area is required for the faucet base, so the base nut can be tightened. Conditions may be  present that would eliminate the need to drill a hole.  A.  A hole previously drilled, covered by a chrome hole cover. Remove the cover and install faucet.  B.  A spray hose that is either not functioning or not desired. Remove the spray hose and plug the outlet  under the main faucet. Install faucet.  Sink drilling. The sink drilling process requires a certain amount of caution and forethought. Porcelain  enameled sinks can be chipped if care is not exercised. Here are two suggested methods.  I. Drill carefully using a high speed drill and a 7/16” carbide tip drill bit.  II. Using a carbide grinding wheel, grind away the porcelain where the 7/16” is to be drilled. Drill a 7/16”  hole through the metal.  CAUTION: Do not allow metal shavings to remain on the porcelain surface of the sink for any length of  time. The metal chips will stain the sink and are hard to remove.  6)  Faucet installation. Remove parts from faucet package. Place chrome plate, then large rubber washer  on faucet stem. Slide stem through hole in sink. Place large washer, lock washer and nut on stem an  tighten securely.  7)  Attach product line to faucet. Place brass nut over tubing. Place plastic ferrule on tube. Insert plastic  tube support. Secure nut to base of faucet, making sure tube does not slide out.  8)  An air gap is provided for in the base of the faucet. Do NOT connect the system drain line to the  dishwasher drain or near the garbage disposal. Backpressure from these units may cause the air gap  to overflow.  Attach black drain line to the 3/16” hose barb on faucet.  Connect the black drain tubing which is shipped loose in the box, to the ¼” hose barb on the faucet by  firmly pressing over the barb. Allow the tubing to relax, then press firmly again to insure proper  seating. Attach other end of drain tubing to the drain saddle.  9)   Attach supply line to saddle valve using #7.  10) Screw ball valve onto tank and attach tubing.  11) Turn supply saddle valve closed tightly to pierce pipe.  Open slowly to make sure fittings are secure. ...
  • Page 4 1 YEAR LIMITED WARRANTY  LANCASTER, warrants your under sink Reverse Osmosis drinking water unit, to  be free of defects in material and workmanship, for a period of one year, under normal  use, within the operating conditions listed below. To resolve any warranty problems,  you must first contact your local dealer, they in turn will contact the factory.  Upon proof of purchase, LANCASTER, will repair or replace, at the factory, the  Defective part or unit, and return it to your local dealer. Freight to and from the factory is to be  paid by the buyer. The Pre and Post filter cartridges are warranted for  manufacturers defects only and not for taste and odor problems. The membrane is warranted  separately as stated below. Any accessories, such as pumps and motors, shall be warranted by  the manufacturer of these parts.  The REVERSE OSMOSIS MEMBRANE will be warranted for a three  month shelf life and a twelve month in use period, for a total fifteen months under the  manufactures warranty. Warranty begins from the date of purchase from the  manufacturer. Membrane is warranted against defects when used under standard  Operating conditions. Membranes sent for review will be sent to the manufacture of said  element for review.  Membranes must be kept moist at all times. Defective membranes must be  returned in a sealed bag and kept moist with an appropriate preservative solution or  R.O. water. Membranes returned dry, opened, or improperly packaged can not  be evaluated for warranty and will be returned to the sender at your expense.  Standard Operating Conditions  Membrane type TFM  Maximum feed water pressure 100psi  Water temperature  40­100°F  TDS 2000ppm  pH 3­11  Hardness 10­12 grains  THERE ARE NO OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED  AND THERE IS NO LIABILITY FOR CONSEQUENTIAL DAMAGES  OF ANY NATURE OR KIND.  SERIAL#  11/2008...