Sign In
Upload
Manuals
Brands
ABB Manuals
Protection Device
REM630
User Manuals: ABB REM630 Motor Protection Relay
Manuals and User Guides for ABB REM630 Motor Protection Relay. We have
3
ABB REM630 Motor Protection Relay manuals available for free PDF download: Product Manual, Applications Manual
ABB REM630 Applications Manual (76 pages)
Motor Protection and Control
Brand:
ABB
| Category:
Protection Device
| Size: 5.94 MB
Table of Contents
Table of Contents
7
Section 1 Introduction
11
This Manual
11
Intended Audience
11
Product Documentation
12
Product Documentation Set
12
Document Revision History
12
Related Documentation
13
Symbols and Conventions
13
Symbols
13
Document Conventions
14
Functions, Codes and Symbols
14
Section 2 REM630 Overview
19
Overview
19
Product Version History
19
PCM600 and IED Connectivity Package Version
19
Operation Functionality
20
Product Variants
20
Optional Functions
20
Physical Hardware
21
Local HMI
22
Display
23
Leds
25
Keypad
25
Web HMI
25
Authorization
27
Communication
27
Section 3 REM630 Variants
29
Presentation of Preconfigurations
29
Preconfigurations
30
Preconfiguration a for Asynchronous Motor
32
Application
32
Functions
33
Input/Output Signal Interfaces
34
Preprocessing Blocks and Fixed Signals
35
Control Functions
35
Motor Bay Control QCCBAY
35
Apparatus Control SCILO, GNRLCSWI, DAXCBR, DAXSWI
35
Protection Functions
37
Thermal Overload Protection MPTTR
37
Emergency Start ESMGAPC
38
Motor Startup Supervision STTPMSU
38
Motor Stall Protection JAMPTOC
38
Loss of Load Protection LOFLPTUC
39
Phase Reversal Protection PREVPTOC
39
Motor Negative-Sequence Overcurrent Protection MNSPTOC
40
Non-Directional Overcurrent Protection Phxptoc
41
Non-Directional Earth-Fault Protection Efxptoc
41
Positive-Sequence Overvoltage Protection PSPTOV
41
Positive-Sequence Undervoltage Protection PSPTUV
42
Negative-Sequence Overvoltage Protection NSPTOV
42
Circuit-Breaker Failure Protection CCBRBRF
43
Tripping Logic TRPPTRC
43
Combined Operate and Start Alarm Signal
44
Combined Restart Inhibit and Restart Enable Signal
44
Supervision Functions
44
Trip Circuit Supervision TCSSCBR
44
Fuse Failure and Current Circuit Supervision SEQRFUF, CCRDIF
44
Circuit-Breaker Condition Monitoring SSCBR
45
Measurement and Analog Recording Functions
45
Binary Recording and LED Configuration
47
Preconfiguration B for Asynchronous Motor Including Differential Protection
49
Application
49
Functions
51
Input/Output Signal Interfaces
51
Preprocessing Blocks and Fixed Signals
53
Control Functions
53
Motor Bay Control QCCBAY
53
Apparatus Control SCILO, GNRLCSWI, DAXCBR, DAXSWI
53
Protection Functions
55
Stabilized Three-Phase Differential Protection MPDIF
55
Thermal Overload Protection MPTTR
56
Emergency Start ESMGAPC
57
Motor Startup Supervision STTPMSU
57
Motor Load Jam Protection JAMPTOC
57
Loss of Load Protection LOFLPTUC
58
Phase Reversal Protection PREVPTOC
58
Motor Negative-Sequence Overcurrent Protection MNSPTOC
58
Non-Directional Overcurrent Protection Phxptoc
59
Non-Directional Earth-Fault Protection Efxptoc
60
Positive-Sequence Overvoltage Protection PSPTOV
60
Positive-Sequence Undervoltage Protection PSPTUV
60
Negative-Sequence Overvoltage Protection NSPTOV
60
Circuit-Breaker Failure Protection CCBRBRF
61
Tripping Logic TRPPTRC
61
Combined Operate and Start Alarm Signal
62
Combined Restart Inhibit and Restart Enable Signal
62
Supervision Functions
63
Trip Circuit Supervision TCSSCBR
63
Fuse Failure and Current Circuit Supervision SEQRFUF, CCRDIF
63
Circuit-Breaker Condition Monitoring SSCBR
63
Measurement and Analog Recording Functions
64
Binary Recording and LED Configuration
65
Section 4 Requirements for Measurement Transformers
69
Current Transformers
69
Current Transformer Requirements for Overcurrent Protection
69
Current Transformer Accuracy Class and Accuracy Limit Factor
69
Non-Directional Overcurrent Protection
70
Example for Non-Directional Overcurrent Protection
71
Section 5 Glossary
73
Advertisement
ABB REM630 Applications Manual (56 pages)
Motor Protection and Control
Brand:
ABB
| Category:
Control Unit
| Size: 3.55 MB
Table of Contents
Table of Contents
7
Section 1 Introduction
9
This Manual
9
Intended Audience
9
Product Documentation
10
Product Documentation Set
10
Document Revision History
11
Related Documentation
12
Symbols and Conventions
12
Safety Indication Symbols
12
Manual Conventions
13
Functions, Codes and Symbols
13
Section 2 REM630 Overview
17
Overview
17
Product Version History
17
PCM600 and IED Connectivity Package Version
17
Operation Functionality
18
Product Variants
18
Optional Functions
18
Physical Hardware
18
Local HMI
20
Lcd
20
Leds
23
Keypad
23
Web HMI
23
Authorization
24
Communication
25
Section 3 REM630 Variants
27
Presentation of Preconfigurations
27
Preconfigurations
28
Preconfiguration a for Asynchronous Motor
29
Application
29
Functions
30
Input/Output Signal Interfaces
32
Preprocessing Blocks and Fixed Signals
33
Control Functions
34
Motor Bay Control QCCBAY
34
Apparatus Control SCILO, GNRLCSWI, DAXCBR, DAXSWI
34
Protection Functions
35
Thermal Overload Protection MPTTR
35
Emergency Start ESMGAPC
36
Motor Startup Supervision STTPMSU
36
Motor Stall Protection JAMPTOC
36
Loss of Load Protection LOFLPTUC
37
Phase Reversal Protection PREVPTOC
38
Motor Negative-Sequence Overcurrent Protection MNSPTOC
38
Non-Directional Overcurrent Protection Phxptoc
39
Non-Directional Earth-Fault Protection Efxptoc
40
Positive-Sequence Overvoltage Protection PSPTOV
40
Positive-Sequence Undervoltage Protection PSPTUV
40
Negative-Sequence Overvoltage Protection NSPTOV
40
Circuit-Breaker Failure Protection CCBRBRF
41
Tripping Logic TRPPTRC
42
Combined Operate and Start Alarm Signal
42
Combined Restart Inhibit and Restart Enable Signal
43
Supervision Functions
43
Trip Circuit Supervision TCSSCBR
43
Fuse Failure and Current Circuit Supervision SEQRFUF, CCRDIF
43
Circuit-Breaker Condition Monitoring SSCBR
43
Measurement and Analog Recording Functions
44
Binary Recording and LED Configuration
46
Section 4 Requirements for Measurement Transformers
49
Current Transformers
49
Current Transformer Requirements for Non-Directional Overcurrent Protection
49
Current Transformer Accuracy Class and Accuracy Limit Factor
49
Non-Directional Overcurrent Protection
50
Example for Non-Directional Overcurrent Protection
51
Section 5 Glossary
53
ABB REM630 Product Manual (76 pages)
Relion 630 Series Motor Protection and Control
Brand:
ABB
| Category:
Protection Device
| Size: 2.4 MB
Table of Contents
Table of Contents
2
Description
3
Application
3
Preconfigurations
5
Protection Functions
9
Control
11
Measurement
11
Disturbance Recorder
11
Event Log
11
Disturbance Report
12
Circuit-Breaker Monitoring
12
Trip-Circuit Supervision
12
Self-Supervision
12
Fuse Failure Supervision
12
Current Circuit Supervision
13
Access Control
13
Inputs and Outputs
13
Communication
15
Technical Data
17
Front Panel User Interface
55
Mounting Methods
55
Selection and Ordering Data
57
Accessories
61
Tools
62
Supported ABB Solutions
64
Terminal Diagrams
66
References
69
Functions, Codes and Symbols
70
Document Revision History
73
Advertisement
Advertisement
Related Products
ABB REM615 ANSI
ABB REM615 ANSI 5.0 FP1
ABB REM615 ANS
ABB RELION REB670
ABB RET650 2.1 IEC
ABB REF615 ANSI 5.0 FP1
ABB REL 551 2.3 Series
ABB REL 352
ABB Relion REG650
ABB REL 511-C1 2.5 Series
ABB Categories
Industrial Equipment
Controller
Measuring Instruments
Battery Charger
DC Drives
More ABB Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL