Installation instructions

Ceramic hobs
KM 6200 / 6202 / 6203
KM 6204 / 6206 / 6207 / 6208
KM 6212 / 6213 / 6215 / 6216
en - GB
To avoid the risk of accidents or
damage to the appliance it is
essential to read these instructions
before it is installed and used for the
first time.
M.-Nr. 09 198 690

Advertisement

Table of Contents
loading

Summary of Contents for Miele KM 6200

  • Page 1: Installation Instructions

    Installation instructions Ceramic hobs KM 6200 / 6202 / 6203 KM 6204 / 6206 / 6207 / 6208 KM 6212 / 6213 / 6215 / 6216 en - GB To avoid the risk of accidents or damage to the appliance it is...
  • Page 2: Table Of Contents

    KM 6200 / KM 6202 ........
  • Page 3: Safety Instructions For Installation

    Safety instructions for installation After installing the hob, ensure that The appliance must only be installed the connection cable cannot come into and connected to the electricity contact with the underside of the supply by a suitably qualified and appliance. Make sure that there is no competent person in strict mechanical obstruction, such as a accordance with current national...
  • Page 4 Safety instructions for installation Safety distance above an interim Safety distance above the hob shelf It is not necessary to fit an interim shelf underneath the hob. If an interim shelf is fitted underneath the hob, a minimum safety distance of 110 mm must be maintained between the top of the worktop and the top of the interim shelf.
  • Page 5 (e.g. tall unit) or wall: 50 mm = KM 6200 / 6202 / 6203 100 mm = KM 6204 / 6206 KM 6207 / 6208 / 6212 KM 6213 / 6215 / 6216...
  • Page 6 Safety instructions for installation Safety distance when installing the appliance near a wall with additional niche cladding A minimum safety distance must be maintained between the worktop cut-out and any niche cladding to protect it from heat damage. If the niche cladding is made from a combustible material (e. g. wood) a minimum safety distance e of 50 mm must be maintained between the cut-out and the cladding.
  • Page 7 Safety instructions for installation Hob with frame or bevelled Tiled worktop edges Seal between the hob and the worktop Grout lines a and the hatched area underneath the hob frame must be smooth and even. If they are not the hob will not sit flush with the worktop and the sealing strip underneath the The sealing strip under the edge of the...
  • Page 8: Hob With Frame Or Bevelled Edge

    Hob with frame or bevelled edge Building-in dimensions KM 6200 / KM 6202 a Spring clamps b Front c Casing depth d Casing depth including mains connection box with mains connection cable, L = 1440 mm e Connection for Miele|home...
  • Page 9 Hob with frame or bevelled edge KM 6204 a Spring clamps b Front c Casing depth d Casing depth including mains connection box with mains connection cable, L = 1440 mm e Connection for Miele|home...
  • Page 10 Hob with frame or bevelled edge KM 6206 a Spring clamps b Front c Casing depth d Casing depth including mains connection box with mains connection cable, L = 1440 mm e Connection for Miele|home...
  • Page 11 Hob with frame or bevelled edge KM 6207 a Spring clamps b Front c Casing depth d Casing depth including mains connection box with mains connection cable, L = 1440 mm e Connection for Miele|home f Safety bracket...
  • Page 12 Hob with frame or bevelled edge KM 6208 a Spring clamps b Front c Casing depth d Casing depth including cable exit e Wiring harness, L = 1550 mm f Connection for Miele|home g Mains connection box with mains connection cable, L = 1440 mm...
  • Page 13 Hob with frame or bevelled edge KM 6212 a Spring clamps b Front c Casing depth d Casing depth including mains connection box with mains connection cable, L = 1440 mm e Connection for Miele|home...
  • Page 14 Hob with frame or bevelled edge KM 6213 a Spring clamps b Front c Casing depth d Casing depth including mains connection box with mains connection cable, L = 1440 mm e Connection for Miele|home f Safety bracket...
  • Page 15 Hob with frame or bevelled edge KM 6216 a Spring clamps b Front c Casing depth d Casing depth including mains connection box with mains connection cable, L = 1440 mm e Connection for Miele|home...
  • Page 16: Installation

    Hob with frame or bevelled edge Installation Worktops made of wood ^ Seal the cut surfaces with a suitable The exact positions of the spring heat-resistant sealant to avoid clamps and the safety brackets (only swelling caused by moisture. for hobs with bevelled edge) are shown in the building-in dimensions Make sure that the sealant does not for the particular hob.
  • Page 17 Hob with frame or bevelled edge Granite and marble worktops You will require double-sided tape and silicone (not supplied). ^ Apply silcone to the side edges and the lower edges of the spring clamps and safety brackets. ^ Fix the spring clamps and safety brackets (only for hobs with bevelled edge) in place using double-sided tape c.
  • Page 18: Installing The Hob

    Hob with frame or bevelled edge Installing the hob ^ Feed the hob connection cable down through the cut-out. ^ Position the hob on the spring clamps. ^ Using both hands, press down evenly on the sides of the hob until it clicks into position.
  • Page 19: External Mains Connection Box

    Hob with frame or bevelled edge External mains connection box A minimum safety distance of 150 mm must be maintained between the connection box and the hob and also any other source of heat (cooker, oven etc). If an interim shelf is fitted beneath the hob, the connection box must The connection box can be sited as not be sited between the hob and...
  • Page 20: Flush-Fitted Hobs

    Please take careful note of the detailed diagrams for the cut-out b Casing depth dimensions in granite and marble c Casing depth including mains worktops. connection box with mains connection cable, L = 1440 mm d Stepped cutout e Connection for Miele|home...
  • Page 21 Please take careful note of the detailed diagrams for the cut-out b Casing depth dimensions in granite and marble c Casing depth including mains worktops. connection box with mains connection cable, L = 1440 mm d Stepped cutout e Connection for Miele|home...
  • Page 22: Installation

    Flush-fitted hobs Installation The hob can be installed – in a suitable cut-out in a granite or Flush fit hobs are only suitable for marble worktop. installation in granite, marble, tiled or solid wood worktops. – in a suitable cut-out in a tiled or solid When using a worktop made from wood worktop or a glass worktop any other material, please check first...
  • Page 23 Flush-fitted hobs ^ Make the worktop cut-out as shown Granite and marble worktops in "Building-in dimensions". Preparing the worktop Observe the safety distances (see "Safety instructions for installation"). ^ Feed the mains connection cable down through the cut-out. ^ Centre the hob b in the cut-out. ^ Connect the hob to the mains.
  • Page 24 Flush-fitted hobs ^ Make the worktop cut-out as shown Solid wood, tiled and glass in "Building-in dimensions". worktops Observe the safety distances (see "Safety instructions for installation"). Preparing the worktop ^ Fix the wooden frame d 7 mm below the top edge of the worktop (see diagram).
  • Page 25: Electrical Connection

    3 mm in type H 05 VV-F, available from the isolator switch (including switch, Miele. fuses and relays). Ensure power is not supplied to the Important U.K. appliance until after installation or The appliance is supplied for repair work has been carried out.
  • Page 26: Wiring Diagram

    Electrical connection Wiring diagram The electrical safety of this appliance can only be guaranteed when continuity is complete between it and an effective earthing system, which complies with current local and national safety regulations. It is most important that this basic safety requirement is present and regularly tested and where there is any doubt, the electrical wiring in the home should be inspected by a...