hit counter script
Frigidaire FGET2765KFB Installation Instructions Manual
Frigidaire FGET2765KFB Installation Instructions Manual

Frigidaire FGET2765KFB Installation Instructions Manual

27" (68.6 cm), 30" (76,2 cm) electric wall oven
Table of Contents

Advertisement

Available languages

Available languages

iNSTALLATiON
AND SERVICE MUST BE PERFORMED
BY A QUALiFiED
iNSTALLER.
iMPORTANT:
SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE.
READ AND SAVE THESE INSTRUCTIONS
FOR FUTURE REFERENCE.
FOR YOUR SAFETY: Do not store or use gasoline or other flammable
vapors
and liquids in the vicinity
of this or any other appliance.
Your new wall oven has been designed to fit a limited variety
of cutout sizes to make
the job of installing easier. The first step of your installation should be to measure your
current cutout dimensions
and compare them to the cutout dimensions
chart below for
your model. You may find little or no cabinet work being necessary.
Canada
UnitedStates
Do not remove spacers (if equipped)
on the side walls and/or
on the back of the built=
in oven. These spacers center the oven in the space provided.
The oven must be centered
to prevent
excess heat buildup
that may result in heat damage
or fire.
NOTES:
,,
1. Base must be capable of supporting 150 pounds (68 kg) for 27"
lY2 (3 8 cm) __j_
models and 200 pounds (90 kg) for 30" models.
" Min.
_
2. Allow at least 21 " (53.3 cm) clearance in front of oven for door
_
(_
depth when it is open.
.
_
,_--_- _
°
_- -._____
3. Dimension G (cutout depth) is critical to
__
"C._. J
"--_ ---.._
GT_
::_',
Holefor
the proper installation of the built-in oven.
,
--_
_---_ .......
i zCable
f the oven decorat ve tr m does not butt
_
H
F _
.....
_
_'_._
27 3/16"
aga nst the cab net or f no se s heard on
<_
.....
_
:
,,
convection models, verify dimension G to
r_
";-_
_L-
.......
:
c7_ _,_
assure it is the required depth.
,,
/
,,.-
"'
4. For a cutout height greater than 28V8" o ..-_-'<
,_ 31 ,
_
__-_
-----t._
(71.4 cm) add one 2"(5 cm)
DdSiO_en
_-
X
t,_., _m)
_.4,,.
_
"_
v
_
.......
_pacer
wide wood shim of appropriate
(see note 2)
....._
D_
,|
_ ¢
""C%,, _
/
-'_
\2"
\
height to each side of the
...... -""
_"-_. _
....
\
:
tb. 1 cm)
opening under the appliance side rails.
A
_
Min. /]
5.30"
MODELS ONLY: For a cutout height (H)
_
_
'-_-/
Electrical
s ,,
___,V
Junction Box
greater than 28/8
(72.7 cm) you can order a
2" (5 cm) Wide Wood
larger bottom trim, contact a Service Center and
Spacerif Needed
ask for part #318259703
(for white models),
318259704 (black models), 318259705 (bisque
* Suggested distance from floor is 31 " (78.7cm).
models) or 318259707 (stainless steel models).
Minimum required distance is 4 _/2" (11.4cm).
....
Figure 1
27 and 30 Single Wall Ovens (Double
ovens see Figure 2)
PRODUCT DIM ENSIONS
MODEL
I
A
I
27" (68.6 cm) Wall Oven
27 (68.6)
29 (73.7)
245/_ (62.5)
241/2 (62.2)
30" (76,2 cm) Wall Oven
30 (76,2)
29 (73,7)
281/4 (71.8)
241/2 (62,2)
CUTOUT
DIMENSIONS AND CABINET WIDTH
27" (68.6 cm) Wall Oven
24% (63.2)
251/4(64.1)
231/2 (59.7)
271/4 (69.2)
285h (72.7)
27_A (68.9) Min
30" (76.2 cm) Wall Oven
281/2(72.4)
29 (73.7)
231/2 (59.7)
271/4 (69.2)
28V_ (72.7)
30V8 (76.5) Min
All dimensions are in inches (cm).
Printedin Canada
P/N 318206002
(1106)
Rev. A
English - pages 1-8
Espaflol-
p_iginas 9-16
Fran_ais -pages 17-24

Advertisement

Table of Contents
loading

Summary of Contents for Frigidaire FGET2765KFB

  • Page 1 Canada iNSTALLATiON AND SERVICE MUST BE PERFORMED BY A QUALiFiED iNSTALLER. iMPORTANT: SAVE FOR LOCAL ELECTRICAL iNSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 2: Product Dimensions

    Do not remove spacers (if equipped) on the side walls and/or on the back of the built- in oven. These spacers center the oven in the space provided. The oven must be centered to prevent excess heat buildup that may result in heat damage or fire.
  • Page 3: Electrical Requirements

    3. Electrical Requirements important Notes to the Installer Read all instructions contained in these installation This appliance must be supplied with the proper voltage instructions before installing the wall oven. and frequency, and connected to an individual, properly Remove all packing material from the oven grounded branch circuit, protected by a circuit breaker compartments before connecting the electrical supply or fuse.
  • Page 4: Electrical Connection

    (If your appliance is equipped with white neutral conductor.) This appliance is manufactured with a white neutral Electrical Shock Hazard power supply and a frame connected copper wire, • Electrical ground is required on this appliance. The frame is grounded by connection of grounding •...
  • Page 5: Cabinet Installation

    If oven is used in a new branch circuit installation 5. Cabinet Installation (1996 NEC), mobile home, recreational vehicle, or where local codes DO NOT permit grounding through the neutral (white) wire, the appliance Do not lift the oven by the door handle. frame MUST NOT be connected to the neutral wire...
  • Page 6 Olnstall the Anti-tip MountingScrews Install the Bottom Trim Thewall ovencantip when the door Place the top of the bottom trim over the side trim isopen.Theanti-tipmountingscrews supplied tabs on each side of the oven below the oven door with the wall ovenmustbeinstalledto prevent and fix it using the 2 screws supplied in the mounting tippingof the wall ovenandinjuryto persons.
  • Page 7 For typical under counter installation of an electric built-in oven see Figure below. Only certain cooktop models may be installed over Cabinet side filler panels certain built-in electric oven models. Approved cooktops are necessary to isolate the and built-in ovens are listed by the MFG ID number unit from adjoining cabinets.
  • Page 8: Checking Operation

    5" Max. 6 1/2" Min. Flare (12.7 cm) (16.5cm) Union Right Side of Cabinet 120V/6OHz Flexible Appliance Conduit Grounded (To be Outlet accessible Pressure for shut-off valve _ Regulator Cabinet sides or operation) filler panel Manual _Sh utoff Wall Oven Cabinet Valve Figure 9 =TYPICAL UNDER COUNTER INSTALLATION OF A SINGLE ELECTRIC BUILT-IN OVEN WITH A GAS COOKTOP ABOVE...
  • Page 9 Canada LA INSTALACION Y EL SERVICIO DEBEN SER EFECTUADOS POR UN INSTALADOR CAUFICADO. IMPORTANTE: GUARDE ESTAS INSTRUCCIONES PARA USO DEL iNSPECTOR LOCAL DE ELECTRICIDAD. LEA Y GUARDE ESTAS INSTRUCCIONES PARA REFERENCIA FUTURA. PARA SU SEGURIDAD: No almanece ni utilice gasolina u otros vapores y Iiquidos Estados Unidos inflamables en la proximidad de este o de cualquier...
  • Page 10 No quite los separadores de los muros laterales o/y de la parte posterior del homo empotrado. Estos espadadores centran el homo en el espado provisto. El homo debe estar centrado para prevenir una concentration excesiva de calor que podria resultar en da_os pot el calor o un incendio. I Y2"(3.8 cm) Min.
  • Page 11 cutlas de altura apropiada debajo de los rieles laterales del Notas importantes para el instalador homo. 1. Lea todas las instrucciones contenidas en este manual antes de instalar el homo. 3. Requerirnientos Electricos 2. Saque todo el material usado en el embalaje del Se debe proveer el voltaje y la frecuencia apropiados a compartimiento del homo antes de conectar el...
  • Page 12: Conexi6N Electrica

    (Si su electrodom_stico est_ equipado con un conductor neutro blanco,) Este electrodom_stico est_ fabricado con un Riesgo de choque electrico • Una puesta a tierra se requiere en este aparato, suministro el_ctrico neutro blanco y un alambre de • No Io conecte a la corriente electrica hasta que el cobre conectado al armazon, El armazon esta puesto...
  • Page 13 Si el horno se usa en una instalacion de circuito 5. Instalaci6n del Gabinete ramal nuevo (1996 NEC), en una casa rodante, IMPORTANTE un vehiculo para recreacion o si los codigos locales No levante el homo pot la manija de la puerta. NO permiten la conexion a tierra...
  • Page 14 Instalacion de los tornillos de montado Instaladon de la Guarnid6n Inferior: El homo de pared puede inclinarse Colocar la parte superior de la guarniciOn inferior cuando la puerta esta abierta. Los soportes de sobre las leng0etas laterales del homo, debajo de montaje que vienen con el homo de pared deben la puerta del homo, y fijarlas usando los 2 tornillos de estar ajustadas al armario y al aparato para...
  • Page 15: Dimensiones De Abertura

    Para una instalacion tfpica de un horno electrico incorporado debajo del mostrador, vease la figura 8. Los paneles de relleno laterales SOlo ciertos modelos de tapas de cocina se pueden instalar sobre del gabinete son necesarios para ciertos modelos de hornos electricos empotrados. Las tapas de aislar la unidad de los gabinetes cocina y los hornos empotrados...
  • Page 16 5" Max. 6 1/2" Min. (12.7 cm) (16.5 cm) de gas Lado derecho del Tomacorriente Conector flexible para artefactos gabinete puestoatierra Adaptor de 120Voltios (para tenet acceso a degas /60Hz m,!l Regulador de la wilvula Lados del gabinete de cierre presi6n o panel Ilenador manual)
  • Page 17 L'INSTALLATION ET L'ENTRETIEN DOIVENT f:TRE EFFECTUF:S PAR UN INSTALLATEUR Canada QUALIFliL iMPORTANT: CONSERVEZ POUR L'INSPECTEUR D'_:LECTRICIT_: LOCAL. LISEZ ET CONSERVEZ CES iNSTRUCTiONS POUR RF:FERENCES ULT_:RIEURES. POUR VOTRE SECURITE: N'entreposez pas ou n'utilisez pas d'essence ou d'autres produits inflammables a proximite de cet appareil ou de tout autre appareil _lectrom_nager.
  • Page 18: Dimensions De L'appareil

    N'enlevez pas les entretoises sur les patois laterales et/ou _ I'arri_re du four. Ces entretoises centrent le four dans I'espace fourni. Le four doit etre centre pour prevenir accumulation excessive de chaleur pouvant causer un feu ou des dommages. 1V2"(3.8cm) Min.
  • Page 19 Installateur 3. Exigences electriques 1. Lisez t outes lesinstructions contenues dans cefeuillet Ces appareils doivent _tre branch_s _ une alimentation avant I 'installation dufourencastr_. poss_dant la tension et la fr_quence appropri_es. IIs 2. Enlevez toutlemateriel d'emballage dufouravant d e doivent _tre connect_s _ un circuit d_di_ correctement mis proc_der auraccordement _lectrique.
  • Page 20: Connexions Electriques

    (Si votre appareil possede un c_ble rnuni d'un conducteur blanc neutre.) Cet appareil est fabriqu_ avec un c_ble d'alirnentation Risque de choc eiectrique rnuni d'un fil blanc neutre et d'un fil de rnise a la terre • Laraise_ la terrede cetappareil e st en cuivre branche sur le chassis.
  • Page 21 5. Installation dans I'armoire Cable d'alimentation Fil denude porte, Fil blanc soulevez pas I'appareil par la poign6e de la Fils rouges Risque de lourde charge o Soyez 2 personnes ou plus pour installer ou deplacer I'appareil. • Des blessures ou des dommages a I'appareil peuvent ou vert survenir si vous ne suivez pas cette instruction, _Fil blanc...
  • Page 22 Installation de la moulure inf_rieure: Installez les vis de fixation Le four encastre peut basculer Placez le haut de la moulure inf_rieure par dessus les quand la porte est ouverte. II faut fixer I'appareil petites languettes de chaque c6t_ du four encastr_, I'armoire, a I'aide des vis de fixation...
  • Page 23 L'installation t ypique d'unfour encastr_ _ lectrique s ouslecomptoir e stpr_sent_e _ lafigure8. Seulement certains m odules detables decuisson p euvent _treinstall_s au-dessus decertains m odules d efours II faut fermer les c6tes de I'habitacle encastr_s. Les modules approuv_s pour_trecombin_s par des panneaux de bois pour isoler sontidentifies _ I'aide d'unnum_ro MGF IDetd'un I'appareil des armoires de chaque c6te.
  • Page 24: Note Importante

    18"(45.7 cm) Max. -==='_I ÷ 4"(10 cm) COte droit Prise de I'armoire 120V/6OHz Conduit a gaz mise a la terre Raccord (Acces facile evase pour fermer Regulateur la robinet) de pression C6tes de I'armoire Robinet de ou panneau de fermeture Armoire ou le four est insta% manuel Figure 9 = INSTALLATION TYPIQUE D'UNE TABLE DE CUISSON A GAZ MONTleE AU DESSUS...

This manual is also suitable for:

Ffet2725lsbFpet3085kfc