Frigidaire 242288302 Information
Frigidaire 242288302 Information

Frigidaire 242288302 Information

Ice & water - automatic defrost, side by side - r134a

Advertisement

Quick Links

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT
0° F FREEZER & 37° F FRESH FOOD (2500 ++ V5)
65°F (18°C) Ambient
90°F (32°C) Ambient
Type A with Run/
Start Capacitor
Variable Speed
Standard
Variable Speed
Operating Time
74 to 84%
32 to 40%
100%
Freezer
-2° to 2° F
0° to 4° F
-1° to 3° F
Temperature
-19° to -17° C
-18° to -16° C
-18° to -16° C
Refrigerator
34° to 39° F
34° to 39° F
34° to 39° F
Temperature
1° to 4° C
1° to 4° C
1° to 4° C
Low Side Pressure
5 to 12 psig
5 to 12 psig
N/A
(cut-in)
43 to 83 kPa
43 to 83 kPa
Low Side Pressure
-2 to 2 psig
-2 to 2 psig
-2 to 2 psig
(cut-out)
-14 to 14 kPa
-14 to 14 kPa
-14 to 14 kPa
High Side
90 to 105 psig
90 to 115 psig
120 to 135 psig
Pressure (last
621 to 724 kPa
621 to 793 kPa
827 to 931 kPa
1
/
cycle)
3
Wattage (last
1
/
cycle)
50 to 60
90 to 130
60 to 70
3
Amps (running)
0.5 to 0.9
0.7 to 1.1
0.6 to 1.0
Base Voltage
115 vac (127 vac max)
DEFROST SPECIFICATIONS
Thermostat
Heater
Cabinet Size
Cut-in
Cut-out
Watts
23' CD, 26'
25° F (-4° C)
47° F (8° C)
450
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
CONDENSER FAN MOTOR
Watts
RPM
Amps
3.1
1100 CW Opposite Shaft
0.03 Running
Standard
55 to 65%
-1° to 3° F
-18° to -16° C
IMPORTANT: PLEASE RETURN THIS SHEET TO ITS ORIGINAL LOCATION
34° to 39° F
1° to 4° C
Error Codes
5 to 12 psig
43 to 83 kPa
Display
-2 to 2 psig
FZ
FF
-14 to 14 kPa
--
OP-
130 to 155 psig
896 to 1069 kPa
--
OP¯
100 to 140
OP
--
0.8 to 1.2
--
SH-
--
SH¯
SH
--
Ohms
30
SY
CF
SY
CE
SY
EF
ISOLATED
INTERFACE
USER
SERVICE DATA SHEET
242288302
ICE & WATER - AUTOMATIC DEFROST
SIDE BY SIDE - R134a
Special Modes
Display
Activate/Deactivate
Interpretation
Mode
(press for up to 10 sec.
FZ
FF
simultaneously)
Open FF
Manual
d
F
+ and -/same to deactivate
mid-level thermistor
Defrost
Open FF upper-level
Display/
77
77
^ and -/set
thermistor
Showroom
Open FZ thermistor
Sabbath
Sb
Sb
V
and +/same to deactivate
Shorted FF mid-level
Diagnostic
No FF or FZ display,
^ and
V
/+ to deactivate
thermistor
all UI LEDs on.
Notes:
Shorted FF upper-level
thermistor
• Always check for pin back-outs, pinched or damaged wires
before replacing components.
Shorted FZ thermistor
• Determine whether failure is caused by the component, main
control board or wiring. Contact TID before replacing main
UI to Main Control Board
control board.
communication failure;
• Refer to Service Manual for additional information.
on start up
UI Main Control Board
communication error;
after a period in operation
Evaporator fan failure
Diagnostic Mode
Activate:
Press ^ and V temperature pads for up to 10 sec. simultaneously. Press + to advance through tests.
Deactivate:
Press + for up to 10 sec. Diagnostic Mode will automatically deactivate after 5 min. of inactivity.
Note: Silence alarm.
• Tests marked with "*" may not be applicable to this unit and will not be displayed in Diagnostic Mode.
• Tests displayed in diagnostic mode but not described below are for internal purposes only; advance through.
• View UI display for "on," "off," "CL," "OP," "SH," "LO," "HI" or numerical results of tests.
• Listen for operating sounds; feel for heat or air flow as appropriate to determine results of tests.
Test
To activate test:
Passing result
--
First Screen
--
All LED lights on UI illuminated
--
Second Screen
--
All segments on UI temperature displays illuminated
--
Third Screen
--
Blank UI display, no lights illuminated, no shadowing; "-" and "+"
blinking on FF display side to show location.
28
Dispenser Paddle
Press disp. paddle
"on" on UI when depressed; "off" when released
1*
Standard Compressor
Press set
Compressor and Condenser Fan running when "on"; stopped when "off"
and Condenser Fan
2
Defrost Heater
Press set
Defrost limit switch must be closed; verify "CL" in test 26.
Feel for heat from defrost heater when "on".
If "OP" in test 26, heater will not activate.
3
FF Light
Press set
With FF door open, FF lights on when "on"; off when "off"
8
Water Valve
Press set
Be prepared to collect water at dispenser.
(Dispenser)
Water dispenses when "on"; stops when "off"
9
FZ Light
Press set
With FZ door open, FZ lights on when "on", off when "off"
10
Auger Motor
Press set
FZ door must be closed.
Motor running when "on"; motor stopped when "off"
11
Cube/Crush
Press set
Do not leave solenoid in activated state.
Solenoid
Solenoid activated when "on"; deactivated when "off"
41*
Perfect Temp
Press set
PTD UI illuminated when "on", off when "off"
Drawer (PTD)
12*
VCC Condenser Fan
Press set
Fan running when "on"; stopped when "off"
38*
VCC Compressor
Press set
Compressor running when "on"; stopped when "off"
Fan running for minimum of 10 sec. when "LO" or "HI"; stopped when
15
Evaporator Fan
Press set
"off". Feedback failure if fan starts but runs less than 10 sec. Listen for
speed change from "LO" to "HI".
22
Damper
Press set
With inspection mirror, observe damper open when "OP"; closed when "CL"
23
FF Door
Open/close FF door
"CL" on UI when door closed; "OP" when open
24
FZ Door
Open/close FZ door
"CL" on UI when door closed; "OP" when open
26
Defrost Limit Switch
Activates automatically
"CL" on UI when closed; "OP" when open
36
Ice Chute Door
Depress ice chute door
"OP" on UI when manually opened; "CL" when closed. Or, using "set",
or press set
"OP" on UI when fully opened or "CL" when fully closed by the motor.
29
FF Thermistor
Activates automatically
UI shows temperature sensed by FF thermistor; pass if within 10°F of
Mid-level
temperature measured with gauge at mid-level FF thermistor location.
"OP-" if open; "SH-" if short
30
FZ Thermistor
Activates automatically
UI shows temperature sensed by FZ thermistor; pass if within 10°F of temperature
measured with gage at FZ thermistor location.
"OP" if open; "SH" if short
33
Ambient Thermistor
Activates automatically
UI shows temperature sensed at main board; pass if within +20°F/-10°F
@ Main Board
of temperature measured with gauge at main board location.
"OP" if open; "SH" if short
35
FF Thermistor
Activates automatically
UI shows temperature sensed by upper level FF thermistor; pass if within
Upper-Level
10°F of temperature measured with gauge at upper-level FF thermistor
location. "OP¯" if open; "SH¯" if short
34
Ambient Thermistor
Activates automatically
UI shows temperature sensed at UI; pass if within +20°F/-10°F of tem-
@ UI
perature measured with gauge at UI location. "OP" if open; "SH" if short
46
Humidity Sensor
Activates automatically
"OP" if open, "SH" if short
AC Heater System: Displays %RH
DC Heater System: "HI" – heater should be on
%RH is displayed when humidity is between "Lo" and "HI" values; heater
could be on or off.
47*
Dispenser
Press set
AC Heater System: "--" ; test not available
Pocket Heater
DC Heater System: heater on when "on", off when "off"
0-
Firmware Parameters
Press set
Displays digit sequence; record
2-
Main Board Firmware
Press set
Displays digit sequence; record
4-
UI Firmware
Press set
Displays digit sequence; record
IMPORTANT SAFETY NOTE
The information provided herein is designed to assist qualified repair personnel
only. Untrained persons should not attempt to make repairs due to the possibility of
electrical shock. Disconnect power cord before servicing this appliance.
IMPORTANT
If any green grounding wires are removed during servicing, they must be returned
to their original position and properly secured.
"Lo" – heater should be off
CAUTION
All electrical parts and wiring must be shielded
from torch flame. DO NOT allow torch to touch
insulation; it will char at 200°F and flash ignite
(burn) at 500°F. Excessive heat will distort the
plastic liner.

Advertisement

loading

Summary of Contents for Frigidaire 242288302

  • Page 1 0° F FREEZER & 37° F FRESH FOOD (2500 ++ V5) Activate: Press ^ and V temperature pads for up to 10 sec. simultaneously. Press + to advance through tests. 242288302 65°F (18°C) Ambient 90°F (32°C) Ambient Type A with Run/ Deactivate: Press + for up to 10 sec.
  • Page 2 ICE MAKER SPECIFICATIONS ICE MAKER INFORMATION Water Fill Electrical 115 vac (127 vac max) Test Cycling Adjustment Thermostat Opens at 48° F ( 9° C), Closes at 9° F ( -13° C) Press the momentary contact on the ON/OFF switch for approximately 15 seconds. Ice maker will continue to complete the cycle.