hit counter script
Sanyo PLC-ZM5000L - 5000 Lumens Manual
Sanyo PLC-ZM5000L - 5000 Lumens Manual

Sanyo PLC-ZM5000L - 5000 Lumens Manual

Expand serial command function spcifications
Hide thumbs Also See for PLC-ZM5000L - 5000 Lumens:
Table of Contents

Advertisement

EXPAND SERIAL COMMAND
FUNCTIONAL SPECIFICATIONS
PLC-ZM5000
PLC-ZM5000L
Ver.1.00
SANYO Electric Co., Ltd
DS Company
Projector Division

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo PLC-ZM5000L - 5000 Lumens

  • Page 1 EXPAND SERIAL COMMAND FUNCTIONAL SPECIFICATIONS PLC-ZM5000 PLC-ZM5000L Ver.1.00 SANYO Electric Co., Ltd DS Company Projector Division...
  • Page 2: Table Of Contents

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications Contents Overview ........................9 Serial Interface Specification ..................9 Transfer Specification ....................9 Connection ......................9 Notes for communication ..................10 Notation Convention ....................10 Functional Execution Command Table ..............11 Image Command Table..................11 PC Adjust Control Command Table ..............11 Input Control Command Table ................11 Screen Control Command Table .................12 Lamp Command Table..................12 Sound Command Table..................12...
  • Page 3 PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.4.9 CF_COLTEMP Command ..................21 8.4.10 CF_OFFSET- Command ..................21 8.4.11 CF_NZRED Command ..................22 8.4.12 CF_PROGV Command..................22 8.4.13 CF_IMAGE Command...................22 8.4.14 CF_IMAGEADJ Command ...................23 PC Adjust Control Command ................24 8.5.1 CF_FSYNC Command ..................24 8.5.2 CF_TDOTS Command ..................24 8.5.3 CF_CLPPHASE Command ...................24 8.5.4...
  • Page 4 PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.7.14 CF_CEIL Command ....................37 8.7.15 CF_REAR Command ....................37 8.7.16 CF_SCREENASPECT Command.................37 Lamp Command ....................38 8.8.1 CF_LAMPMODE Command .................38 8.8.2 CF_LAMPLIFECONTRL_ Command ..............38 Sound Command ....................39 8.9.1 CF_VOLUME Command ..................39 8.9.2 CF_MUTE Command ....................39 8.9.3 CF_BLTINSP Command ..................39 8.10 Setting Command ....................40 8.10.1...
  • Page 5 PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.10.30 CF_STANDBYMODE Command ................48 8.10.31 CF_ON-STA Command ..................49 8.10.32 CF_POINTER Command..................49 8.10.33 CF_PTIMEMODE Command.................49 8.10.34 CF_PTIMER Command ..................49 8.10.35 CF_PTIME Command....................50 8.10.36 CF_KEYDIS Command ..................50 8.10.37 CF_PJPINCODE Command..................50 8.10.38 CF_SHUTPROT Command...................51 8.10.39 CF_SHUTRELEASE Command................51 8.10.40 CF_SHUTH Command ..................51 8.10.41 CF_CCAPTIONDISP Command ................51 8.10.42 CF_CCAPTIONCOLOR Command...............52...
  • Page 6 PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.4.14 CR_OFFSET-B Command ..................58 9.4.15 CR_NZRED Command..................58 9.4.16 CR_PROGV Command ..................59 9.4.17 CR_IMAGE Command ..................59 9.4.18 CR_IMGGMD Command ..................59 PC Adjust Status Read Command ..............60 9.5.1 CR_FSYNC Command ..................60 9.5.2 CR_TDOTS Command ..................60 9.5.3 CR_CLPPHASE Command ..................60 9.5.4 CR_H-POS Command...................60...
  • Page 7 PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.8.3 CR_VPOS Command ....................71 9.8.4 CR_HSCALE Command ..................71 9.8.5 CR_HPOS Command ....................71 9.8.6 CR_ KYSTNMODE Command ................72 9.8.7 CR_CORNERTESTPAT Command ..............72 9.8.8 CR_CEIL Command ....................72 9.8.9 CR_REAR Command ....................72 9.8.10 CR_SCREENASPECT Command ................72 Lamp Status Read Command ................73 9.9.1 CR_LAMPREPL Command ..................73 9.9.2...
  • Page 8 PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.11.19 CR_FILTIMER Command..................80 9.11.20 CR_FILCOND Command ..................80 9.11.21 CR_FILREPL Command ..................80 9.11.22 CR_FANSPEED Command...................80 9.11.23 CR_SIMPLEMODE Command ................81 9.11.24 CR_RCODE Command ..................81 9.11.25 CR_RSENS Command..................81 9.11.26 CR_RTYPE Command ..................81 9.11.27 CR_P-MANE Command ..................82 9.11.28 CR_P-MANETIME Command ................82 9.11.29 CR_STANDBYMODE Command ................82 9.11.30 CR_ON-STA Command..................82 9.11.31 CR_POINTER Command ..................82...
  • Page 9: Overview

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications Overview 0û This Functional Specification defines communication with PJ-Net organizer for PLC-ZM5000 / ZM5000L. 0û Supporting Firmware Ver. 1.x of the projector. 0û Commands in this document are to communicate with PJ-Net organizer, but most commands are used to control a projector remotely from a computer with RS-232C.
  • Page 10: Notes For Communication

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications Notes for communication Expand Serial Command is defined as a single command per line that starts with “C” and ends with carriage return (0x0D). There are two types of commands; Functional Execution Commands and Status Read Command.
  • Page 11: Functional Execution Command Table

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications Functional Execution Command Table 5.1 Image Command Table Item Execute command CF_BRIGHT_%1 [CR] Set value of Brightness CF_CONT_%1 [CR] Set value of Contrast CF_COLOR_%1 [CR] Set value of Color CF_TINT_%1 [CR] Set value of Tint CF_IRIS_%1 [CR] Set ON/OFF of Iris function CF_SHARP_%1 [CR]...
  • Page 12: Screen Control Command Table

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications Screen Control Command Table Execute command Item CF_SCREEN_%1 [CR] Select Screen size CF_DZCENT _%1 [CR] Cancel Digital Zoom mode CF_VSCALE_%1[CR] Set V Scale CF_VPOS_%1[CR] Set V Position CF_HSCALE_%1[CR] Set H Scale CF_HPOS_%1[CR] Set H Position CF_KEYSTONE _%1 [CR] Set Keystone correction CF_KYSTNMODE _%1 [CR]...
  • Page 13: Other Command Table

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications Set time to display Filter cleaning / replacement warning CF_FILTIMER_%1[CR] on screen CF_FILCTL_%1[CR] Execute operation of scroll of filter CF_FILSCRL_%1[CR] Reset Filter scroll counter CF_FANSPEED_%1 [CR] Set level of Fan Speed CF_SIMPLEMODE_%1 [CR] Set Simple mode function CF_RCODE_%1 [CR] Select Remote Control Code Select location of infrared remote receiver of remote...
  • Page 14: Status Read Command Table

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications Status Read Command Table Image Status Read Command Table Status Read command Item CR_BRIGHT [CR] Get value of Brightness CR_CONT [CR] Get value of Contrast CR_COLOR [CR] Get value of Color CR_TINT [CR] Get value of Tint CR_IRIS [CR] Get setting status of Iris function CR_SHARP [CR]...
  • Page 15: Screen Status Read Command Table

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications CR_NMSLOT4[CR] Get terminal information of Input4. CR_IDSLOT1[CR] Get ID information of Input1 CR_IDSLOT2[CR] Get ID information of Input2 CR_IDSLOT3[CR] Get ID information of Input3 CR_IDSLOT4[CR] Get ID information of Input4 Screen Status Read Command Table Status Read command Item CR_SCREEN [CR]...
  • Page 16: Other Status Read Command Table

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications CR_HDMISOUND[CR] Get status of Sound mode of HDMI setup. CR_FILREMAIN[CR] Get remaining number of usable Filter scroll CR_FILH[CR] Get Filter used time Get time to display Filter cleaning / replacement warning on CR_FILTIMER[CR] screen CR_FILCOND[CR] Get status of filter clog CR_FILREPL[CR]...
  • Page 17: Error Code Table

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications Error Code Table Error Code Contents -When the received data cannot be decoded -Parameter designation error (wrong digit number, including invalid value, etc.) Normal reception (This is “Not” error) The function is not available in the selected Mode Selected value is out of range (Not reflected) Command mismatched to Hardware (the command is for Optional function which is not implemented)
  • Page 18: Functional Execution Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications Functional Execution Command 8.1 Format 1) PC issues commands in format as below: Pattern1: “CF_ COMMAND” [CR] Pattern2: “CF_ COMMAND _” %1 [CR] CF_: Header COMMAND: String %1: Parameter (String) _: Space (To separate COMMAND and Parameter) 2) The projector decodes the received command and when it is ready to receive the next command, it returns the response.
  • Page 19: Image Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications Image Command 8.4.1 CF_ BRIGHT Command Command “CF_BRIGHT_%1” [CR] “000-063”--------------- Directly specify setting value of Brightness “UP”--------------------- Increment setting value of Brightness by 1 “DN”--------------------- Decrement setting value of Brightness by 1 Set user controlled value of Brightness (Available only in the normal Power ON status) Details The value set by this command will not be stored in the projector’s memory.
  • Page 20: Cf_Iris Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.4.5 CF_IRIS Command Command “CF_IRIS_%1” [CR] “OFF” ---------------- Set Iris function to OFF “ON” ------------------- Set Iris function to ON Set Iris function to ON/OFF. (Available only in the normal Power ON status) The setting status with this command will not be stored in the projector’s memory. Details Therefore, when the power is turned to ALL OFF status, the value returns to the original setting.
  • Page 21: Cf_Wbal- Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.4.8 CF_WBAL- Command Command “CF_WBAL-%1_%2” [CR] “R” --------- RED “G” --------- GREEN “B” --------- BLUE “000-063”------ Directly specify value of Color selected in %1 of White Balance. “UP”-------- Increment setting value of Color specified in %1 of White Balance by 1 “DN”------- Decrement setting value of Color specified in %1 of White Balance by 1 Set value of Color specified in %1 of White Balance (Available only in the normal Power ON status)
  • Page 22: Cf_Nzred Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.4.11 CF_NZRED Command Command “CF_NZRED_%1” [CR] “OFF” ---------------- Cancel Noise Reduction “ON” ------------------- Set Noise Reduction “UP” ----------- The same operation as pressing Up key or Left key “DN” -----------The same operation as pressing Down key or Right key *”UP”...
  • Page 23: Cf_Imageadj Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.4.14 CF_IMAGEADJ Command Command “CF_IMAGEADJ_%1”[CR] “RST”------ Reset adjusted value for the Image “STR1”---- Store current adjusted value to Image 1 “STR2”---- Store current adjusted value to Image 2 “STR3”---- Store current adjusted value to Image 3 “STR4”---- Store current adjusted value to Image 4 “STR5”---- Store current adjusted value to Image 5 “STR6”---- Store current adjusted value to Image 6...
  • Page 24: Pc Adjust Control Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications PC Adjust Control Command 8.5.1 CF_FSYNC Command Command “CF_FSYNC_%1” [CR] “0000-0031” ----------------- Directly specify setting value of Fine Sync “UP” --------------------------- Increment setting value of Fine Sync by 1 “DN” --------------------------- Decrement setting value of Fine Sync by 1 Set value of Fine Sync in PC signal (Available only in the normal Power ON status) Details...
  • Page 25: Cf_H-Pos Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.5.4 CF_H-POS Command Command “CF_H-POS_%1” [CR] “0000-nnnn” -------- Directly specify setting value of Horizontal Position “nnnn” indicates maximum value, which is current value of (Total dots - Display area H) “UP” ------------------- Increment setting value of Horizontal Position by 1 “DN”...
  • Page 26: Cf_Dline Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.5.7 CF_DLINE Command Command “CF_DLINE_%1” [CR] “0100-nnnn” ----------- Directly specify setting value of Display Line “nnnn” indicates maximum value, which is current value of (Total Line - Position V). “UP” ------------------- Increment setting value of Display Line by 1 “DN”...
  • Page 27: Cf_Orgmode Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.5.9 CF_ORGMODE Command Command “CF_ORGMODE_%1” [CR] When input signal is PC Analog; “VGA1” ------------------------ Specify VGA1 “VGA2” ------------------------ Specify VGA2 “XGA1” ------------------------ Specify XGA1 “WXGA3” --------------------- Specify WXGA3 “1080I60” --------------------- Specify 1080i60 “1080I50” --------------------- Specify 1080i50 “1035I”...
  • Page 28: Cf_Pcmodefree Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.5.11 CF_PCMODEFREE Command Command “CF_PCMODEFREE_%1” [CR] “1” --------------------------- Set Mode1 to Free status “2” --------------------------- Set Mode2 to Free status “3” --------------------------- Set Mode3 to Free status “4” --------------------------- Set Mode4 to Free status “5”...
  • Page 29: Input Control Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.6 Input Control Command 8.6.1 CF_INPUT Command Command “CF_INPUT_%1” [CR] “1”------------------------- Select Input 1 (not switching Source) “2”------------------------- Select Input 2 (not switching Source) “3”------------------------- Select Input 3 (not switching Source) “4”------------------------- Select Input 4 (Network viewer) “UP”---------------------- Increment Input No.
  • Page 30: Cf_Input 1 Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.6.3 CF_INPUT 1 Command Command “CF_INPUT1_%1” [CR] “DIGITAL” ---------------- Select PC Digital Input “ANALOG” --------------- Select PC Analog Input “SCART” ----------------- Select SCART Input “HDCP” ------------------- Select DVI HDCP Input “HDMI” -------------------- Select HDMI Input Select Input 1 as well as Source specified in %1 Details (Available only in the normal Power ON status)
  • Page 31: Cf_System Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.6.7 CF_SYSTEM Command Command “CF_SYSTEM_%1” [CR] “VGA1” --------------------------- Select VGA1 “VGA2” --------------------------- Select VGA2 “XGA1” --------------------------- Select XGA1 “WXGA3” --------------------- Select WXGA3 “1080P” ------------------------ Select 1080p “1080I” ------------------------ Select 1080i “1035I” ------------------------ Select 1035i Input is “720P”...
  • Page 32: Screen Control Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.7 Screen Control Command 8.7.1 CF_SCREEN Command Command “CF_SCREEN_%1” [CR] “NORMAL” ---------------------- Select Normal mode “FULL” --------------------------- Select Full screen mode “WIDE” --------------------------- Select Wide(16:9) mode “ZOOM” -------------------------- Select Zoom mode “TRUE” -------------------------- Select True mode Input is Computer “CUSTOM”...
  • Page 33: Cf_Vscale Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.7.3 CF_VSCALE Command Command “CF_VSCALE_%1” [CR] “035” ---------------------- +35 “031” ---------------------- +31 ÿ “002” ---------------------- +2 “001” ---------------------- +1 “000” ---------------------- ±0 “ 01” --------------------- 1 “ 02” --------------------- 2 ÿ “ 31” --------------------- 31 “...
  • Page 34: Cf_Hscale Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.7.5 CF_HSCALE Command Command “CF_HSCALE_%1” [CR] “035” ---------------------- +35 “031” ---------------------- +31 ÿ “002” ---------------------- +2 “001” ---------------------- +1 “000” ---------------------- ±0 “ 01” --------------------- 1 “ 02” --------------------- 2 ÿ “ 31” --------------------- 31 “...
  • Page 35: Cf_Keystone Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.7.7 CF_KEYSTONE Command Command “CF_KEYSTONE _%1” [CR] “UP” ------------- Correct Keystone distortion to reduce upper part of image “FUP” ----------- Correct Keystone distortion to reduce upper part by 2 steps “DN” ------------- Correct Keystone distortion to reduce lower part of image “FDN”...
  • Page 36: Cf_Corner-Ur Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.7.10 CF_CORNER-UR Command Command “CF_CORNER-UR_%1”[CR] “UP” ------------ Correct the horizontal line of image upwards “DN” ------------ Correct the horizontal line of image downwards “LEFT” --------- Correct the vertical line of image to the left “RIGHT”...
  • Page 37: Cf_Cornertestpat Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.7.13 CF_CORNERTESTPAT Command Command “CF_CORNERTESTPAT_%1”[CR] “RED” ------------Select Red “WHITE” -------- Select White “BLUE” ---------- Select Blue “OFF” ------------ Select Off Display test patterns for Corner correction. (Available in normal Power ON status only) Details The value set by this command is stored in EEPROM and its setting is effective even after ALL is OFF.
  • Page 38: Lamp Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications Lamp Command 8.8.1 CF_LAMPMODE Command Command “CF_LAMPMODE_%1” [CR] “NORMAL” ------------------------ Set Lamp status to Normal mode “ECO1” ------------------------------- Set Lamp status to Eco1 mode “ECO2” ------------------------------- Set Lamp status to Eco2 mode “AUTO” ----------------------------- Set Lamp status to Auto mode Select Lamp mode (Available only in the normal Power ON status) Details The value set by this command is stored in EEPROM and the setting remains...
  • Page 39: Sound Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications Sound Command 8.9.1 CF_VOLUME Command Command “CF_VOLUME_%1” [CR] “000-063” --------------------------- Directly specify value of Volume. “UP” --------------------------------- Increment setting value of Volume by 1 “DN” --------------------------------- Decrement setting value of Volume by 1 Control level of Volume (Available only in the normal Power ON status) Set Volume Up/Down the same way as RC and also directly specify value of Volume.
  • Page 40: Setting Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.10 Setting Command 8.10.1 CF_LANG Command Command “CF_LANG_%1” [CR] “ENG” --------------------------- Select ENGLISH “DEU” --------------------------- Select German “FRA” --------------------------- Select French “ITA” ----------------------------- Select Italian “ESP” ---------------------------- Select Spanish “POR” --------------------------- Select Portuguese “NED” --------------------------- Select Dutch “SVE”...
  • Page 41: Cf_Inputbutton Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.10.4 CF_INPUTBUTTON Command Command “CF_INPUTBUTTON_%1” [CR] “MODE1” ------------------------- Set Input button operation to MODE1 “MODE2” ------------------------- Set Input button operation to MODE2 “MODE3” ------------------------- Set Input button operation to MODE3 Set Input button operation mode. (Available in normal Power ON status only). Details The status set by this command is stored in EEPROM and its setting is effective after ALL is OFF...
  • Page 42: Cf_Logo Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.10.7 CF_LOGO Command Command “CF_LOGO_%1_%2” [CR] “0000 – 9999” ------------- Directly set Logo PIN code “OFF” ---------------------------Cancel Logo display “DFLT” ------------------------- Select Logo of Factory Default “USER” ------------------------ Select User “UP” ---------- The same operation as pressing Up key or Left key “DN”...
  • Page 43: Cf_Pipmaininp Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.10.10 CF_PIPMAININP Command Command “CF_PIPMAININP_%1_%2” [CR] “1” -------------------- Select Input 1 “2” -------------------- Select Input 2 “3” -------------------- Select Input 3 “DIGITAL” ---------------- Select DVI Input “ANALOG” --------------- Select Analog Input “VIDEO” ------------------- Select Composite Video Input “S-VIDEO”...
  • Page 44: Cf_Pipsize Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.10.12 CF_PIPSIZE Command Command “CF_PIPSIZE_%1_%2” [CR] “1” -------------------- Set main picture size to 10% “2” -------------------- Set main picture size to 20% “3” -------------------- Set main picture size to 30% “4” -------------------- Set main picture size to 40% “5”...
  • Page 45: Cf_Pipstore Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.10.15 CF_PIPSTORE Command Command “CF_PIPSTORE_%1” [CR] “USER1”---- Store current setting status to User 1 “USER2”---- Store current setting status to User 2 “USER3”---- Store current setting status to User 3 “USER4”---- Store current setting status to User 4 “USER5”---- Store current setting status to User 5 Store setting status of “Picture in Picture”.
  • Page 46: Cf_Hdmi Sound Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.10.19 CF_HDMI SOUND Command Command “CF_HDMI SOUND_%1”[CR] “HDMI” ----------------------- Select PCM sound (Digital sound) “EXTERNAL” ------------- Select External sound input Select sound mode of HDMI setup. The status set by this command is stored in EEPROM and its setting is effective Details after ALL is OFF This command is available in normal Power ON status.
  • Page 47: Cf_Fanspeed Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.10.24 CF_FANSPEED Command Command “CF_FANSPEED_%1” [CR] “MAX” ------------------------------ Select maximum fan speed “NOR” ------------------------------ Select normal fan speed Switch Fan Control Speed mode.(Available only in the normal Power ON status) Details The status set by this command is stored in EEPROM and setting remains effective even after the power is turned to ALL OFF status.
  • Page 48: Cf_Rsens Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.10.27 CF_RSENS Command Command “CF_RSENS_%1” [CR] “ALL” ----------------------------------- Select top, front and back receiver of projector “FRONTTOP” ------------------------ Select front and top receivers of projector “BACKTOP” -------------------------- Select only back and top receivers of projector “FRONTBACK”...
  • Page 49: Cf_On-Sta Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.10.31 CF_ON-STA Command Command “CF_ON-STA_%1” [CR] “ON” --------------------------- Set Direct on active. “OFF” ------------------------- Set Direct on inactive. “UP” ---------- The same operation as pressing Up key or Left key “DN” ----------The same operation as pressing Down key or Right key *”UP”...
  • Page 50: Cf_Ptime Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.10.35 CF_PTIME Command Command “CF_PTIME_%1” [CR] “001” – “180” -------------------------- Directly specify setting time Set the time for Count down mode of P-timer. (Available only in the normal Power ON status) Details The status set by this command is stored in EEPROM and setting value remains effective even after the power is turned to ALL OFF status.
  • Page 51: Cf_Shutprot Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.10.38 CF_SHUTPROT Command Command “CF_SHUTPROT_%1” [CR] “OFF” ----------- RC and Side panel are both enabled. “RC” ------------- RC is disabled. “KEY” ----------- Side panel is disabled. “BOTH” --------- RC and Side panel are both disabled. Set valid / invalid of Side panel or RC key on Shutter control function Details (Valid only when in the normal Power ON status)
  • Page 52: Cf_Ccaptioncolor Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.10.42 CF_CCAPTIONCOLOR Command Command “CF_CCAPTIONCOLOR_%1”[CR] “COLOR” ------- Select Color “WHITE” -------- Select White Select color of Closed caption. (Valid only when in the normal Power ON status) The status set with this command is stored in EEPROM and its setting is effective even after ALL is OFF.
  • Page 53: Other Commands

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.11 Other Commands 8.11.1 CF_KEYEMU Command Command “CF_KEYEMU_%1” [CR] “RIGHT” ---------------- Move Pointer rightward in On-Screen Display Menu “LEFT” ------------------ Move Pointer leftward in On-Screen Display Menu “UP” ---------------------- Move Pointer to upward On-Screen Display Menu “DN”...
  • Page 54: Cf_Power Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 8.11.3 CF_POWER Command Command “CF_POWER_%1” [CR] “ON” ----------------------------- Power ON “OFF” --------------------------- Power OFF * Issuing another command during countdown process forced countdown operation to be terminated. * Error Code is returned in some projector statuses, which indicates the command is impossible to be executed.
  • Page 55: Status Read Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications Status Read Command 9.1 Format PC issues commands in format as below: “CR_ COMMAND” [CR] Command: String When projector receives the appropriate command, it returns the required data as a string. “000_” %1 [CR] %1: Required Data (String) When the received data cannot be decoded, the projector returns “?”...
  • Page 56: Image Status Read Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.4 Image Status Read Command 9.4.1 CR_BRIGHT Command Command “CR_BRIGHT” [CR] Details Get user controlled value of Brightness Acceptable “000_%1” [CR] Response “000 – 063” Unacceptable “Error Code” [CR] 9.4.2 CR_CONT Command Command “CR_CONT” [CR] Details Get user controlled value of Contrast Acceptable...
  • Page 57: Cr_Sharp Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.4.6 CR_SHARP Command Command “CR_SHARP” [CR] Details Get user controlled value of Sharpness Acceptable “000_%1” [CR] Response “000 – 031” Unacceptable “Error Code” [CR] 9.4.7 CR_GAMMA Command Command “CR_GAMMA” [CR] Details Get user controlled value of Gamma Acceptable “000_%1”...
  • Page 58: Cr_Coltemp Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.4.11 CR_COLTEMP Command Command “CR_COLTEMP” [CR] Details Get Color Temperature setting status Acceptable “000_%1” [CR] “000” --------------------------------- Xlow “001” --------------------------------- Low “002” --------------------------------- Mid Response “003” --------------------------------- High “BLANK” ---- OSD Menu is blank (Neither of Xlow / Low / Mid / High) Unacceptable “Error Code”...
  • Page 59: Cr_Progv Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.4.16 CR_PROGV Command Command “CR_PROGV” [CR] Details Get Progressive scan setting status Acceptable “000_%1” [CR] “ON” ------------------------------ Set Progressive scan On Response “FILM” ----------------------------- Select FILM mode “OFF” ------------------------------ Set Progressive scan Off Unacceptable “Error Code”...
  • Page 60: Pc Adjust Status Read Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.5 PC Adjust Status Read Command 9.5.1 CR_FSYNC Command Command “CR_FSYNC” [CR] Details Get value of Fine Sync Acceptable “000_%1” [CR] “0000 – 0031” Response “Error Code” [CR] --- When command is not available in the given Unacceptable condition (such as being selected input) “?”...
  • Page 61: Cr_Ddots Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.5.6 CR_DDOTS Command Command “CR_DDOTS” [CR] Details Get value of Display Dots Acceptable “000_%1” [CR] “0100 – nnnn” (nnnn = Total Dots – Position H) Response “Error Code” [CR] ---- When command is not available in the Unacceptable given condition (such as being selected input “?”...
  • Page 62: Cr_Orgmode Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.5.8 CR_ORGMODE Command Command “CR_ORGMODE” [CR] Get the original signal of current selected Mode that is set in PC Adj. Details When MODE1- 10 or EXT11-50 is not selected, get the current signal. Acceptable “000_%1”...
  • Page 63: Cr_Setpcadj Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.5.10 CR_SETPCADJ Command Command “CR_SETPCADJ” [CR] Details Get PC signal for current system Acceptable “000_%1” [CR] When input signal is PC Analog; “VGA1” ------------------------ Indicates VGA1 is selected “VGA2” ------------------------ Indicates VGA2 is selected “XGA1”...
  • Page 64: Video Status Read Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.6 Video Status Read Command 9.6.1 CR_SERSYS Command Command “CR_SERSYS” [CR] Get selected current signal. Auto detected signal is returned in Auto mode Details Only available when Input is Y,Pb/Cb,Pr/Cr, S-Video or Video. (This is not the case for PC-Analog and HDMI signals) Acceptable “000_%1”...
  • Page 65: Input Read Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.7 Input Read Command 9.7.1 CR_INPUT Command Command “CR_INPUT” [CR] Details Get selected INPUT No. Acceptable “000_%1” [CR] Response “1 – 4” Unacceptable “Error Code” [CR] 9.7.2 CR_SOURCE Command Command “CR_SOURCE” [CR] Details Get selected source Acceptable “000_%1”...
  • Page 66: Cr_Srcinp3 Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.7.5 CR_SRCINP3 Command Command “CR_SRCINP3” [CR] Details Get Source of INPUT3 Acceptable “000_%1” [CR] “VIDEO” ----------------------- in Video mode Response “S-VIDEO” -------------------- in S-video mode “YPBPR” ---------------------- in Y,Pb/Cb,Pr/Cr mode Unacceptable “Error Code” [CR] 9.7.6 CR_SRCINP4 Command Command...
  • Page 67: Cr_System Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.7.7 CR_SYSTEM Command Command “CR_SYSTEM” [CR] Details Get selected System Acceptable “000_%1” [CR] “VGA1” ------------------------- indicates VGA1 is selected “VGA2” ------------------------- indicates VGA2 is selected “XGA1” ------------------------- indicates XGA1 is selected “WXGA3” ---------------------- indicates WXGA3 is selected “1080P”...
  • Page 68: Cr_Syslist Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.7.8 CR_SYSLIST Command Command “CR_SYSLIST” [CR] Details Get possible systems for System list Acceptable “000_%1_%2_---_%x” [CR] Error Code “101” is returned for no signal. Otherwise following values are returned according to Source. When input is PC-Analog; “XGA1”...
  • Page 69: Cr_Hmslot Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.7.10 CR_HMSLOT Command Command “CR_HMSLOT” [CR] Details Get the total number of Input. Acceptable “000_%1” [CR] “004” ------------ When PJ-Net is attached. Response “003” ------------ When PJ-Net is not attached. Unacceptable “Error Code” [CR] 9.7.11 CR_NMSLOT1 Command Command “CR_NMSLOT1”...
  • Page 70: Cr_Idslot1 Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.7.15 CR_IDSLOT1 Command Command “CR_IDSLOT1” [CR] Get ID information of Input1. This command is to determine sources possible to Details input. Acceptable “000_%1” [CR] “32” --------------- On-board (HDMI and D-Sub) Response Available source: DIGITAL, ANALOG, SCART, HDCP, HDMI Unacceptable “Error Code”...
  • Page 71: Screen Status Read Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.8 Screen Status Read Command 9.8.1 CR_SCREEN Command Command “CR_SCREEN” [CR] Details Get selected screen image size Acceptable “000_%1” [CR] “NORMAL” ---------------------- Normal mode “FULL” --------------------------- Full screen mode “WIDE” --------------------------- Wide(16:9) mode “TRUE” --------------------------- True mode Response “ZOOM”...
  • Page 72: Cr_ Kystnmode Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.8.6 CR_ KYSTNMODE Command Command “CR_KYSTNMODE” [CR] Details Get setting status of Keystone Store Mode Acceptable “000_%1” [CR] “STR” ---------------------- Store mode is “Store” Response “RST” ---------------------- Store mode is “Reset” Unacceptable “?” [CR] -------------------- When unknown command is received 9.8.7 CR_CORNERTESTPAT Command Command...
  • Page 73: Lamp Status Read Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.9 Lamp Status Read Command 9.9.1 CR_LAMPREPL Command Command “CR_LAMPREPL” [CR] Details Get information of Lamp Replacement time Acceptable “000_%1” [CR] “1Y” ----------------- indicates over lamp replacement time Response “1N” ----------------- indicates under lamp replacement time Unacceptable “?”...
  • Page 74: Cr_Projh Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.9.6 CR_PROJH Command Command “CR_PROJH” [CR] Details Get total running time of Projector (in hours) Acceptable “000_%1” [CR] Response “0000000 – 0099999” Unacceptable “Error Code” [CR] 9.9.7 CR_HMLAMP Command Command “CR_HMLAMP” [CR] Details Get total lamp number Acceptable “000_%1”...
  • Page 75: Sound Status Read Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.10 Sound Status Read Command 9.10.1 CR_VOLUME Command Command “CR_VOLUME” [CR] Get volume value by user control Details * When input signal is Network, error code “101” is returned. Acceptable “000_%1” [CR] Response “000 – 063” Unacceptable “Error Code”...
  • Page 76: Setting Status Read Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.11 Setting Status Read Command 9.11.1 CR_LANG Command Command “CR_LANG” [CR] Details Get selected language Acceptable “000_%1” [CR] “ENG” -------------------------- English is selected “DEU” -------------------------- German is selected “FRA” -------------------------- French is selected “ITA” --------------------------- Italian is selected “ESP”...
  • Page 77: Cr_Backgnd Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.11.5 CR_BACKGND Command Command “CR_BACKGND” [CR] Details Get setting status of Screen for no signal Acceptable “000_%1” [CR] “BLUE” -------------------------------- Blue Back is selected Response “USER” ------------------------------- User is selected “BLACK” ------------------------------ Black Back is selected Unacceptable “Error Code”...
  • Page 78: Cr_Pipmaininp Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.11.10 CR_PIPMAININP Command Command “CR_PIPMAININP” [CR] Details Get Input and Source for “Picture in Picture”. (Main picture) Acceptable “000_%1_%2” [CR] “1” -------------------- Input1 is selected “2” -------------------- Input2 is selected “3” -------------------- Input3 is selected “DIGITAL”...
  • Page 79: Cr_Pipframelock Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.11.13 CR_PIPFRAMELOCK Command Command “CR_PIPFRAMELOCK” [CR] Details Get setting status of Frame lock in “Picture in Picture”. Acceptable “000_%1” [CR] “MAIN” -------------------- Main picture is selected Response “SUB” --------------------- Sub picture is selected Unacceptable “Error Code”...
  • Page 80: Cr_Filh Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.11.18 CR_FILH Command Command “CR_FILH” [CR] Details Get Filter used time Acceptable “000_%1” [CR] Response “00000 - 99999” Unacceptable “Error Code” [CR] 9.11.19 CR_FILTIMER Command Command “CR_FILTIMER” [CR] Details Get Filter used time Acceptable “000_%1”...
  • Page 81: Cr_Simplemode Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.11.23 CR_SIMPLEMODE Command Command “CR_SIMPLEMODE” [CR] Details Get setting status of Simple mode. Acceptable “000_%1” [CR] “ON” ------------------------ Simple mode is ON Response “OFF” ---------------------- Simple mode is OFF Unacceptable “Error Code” [CR] 9.11.24 CR_RCODE Command Command “CR_RCODE”...
  • Page 82: Cr_P-Mane Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.11.27 CR_P-MANE Command Command “CR_P-MANE” [CR] Details Get setting status of Power management Acceptable “000_%1” [CR] “OFF” ------------------------ Power Management is disabled “READY” -------------------- Power Management is set to Ready Response “SHUTDOWN” ------------ Power Management is set to Shut Down mode Unacceptable “Error Code”...
  • Page 83: Cr_Ptimemode Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.11.32 CR_PTIMEMODE Command Command “CR_PTIMEMODE” [CR] Details Get setting status of count up/down mode in P-timer Acceptable “000_%a” [CR] “COUNTUP” -------------------- Set P-timer to Count up mode Response “COUNTDN” -------------------- Set P-timer to Count down mode Unacceptable “Error Code”...
  • Page 84: Cr_Pjlocknow Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.11.37 CR_PJLOCKNOW Command Command “CR_PJLOCKNOW” [CR] Details Get actual setting status of PIN code lock Acceptable “000_%1” [CR] “LOCK” ------ PJ is locked PIN code lock is set to ON1/ON2 on the menu and PJ PIN code is not entered, therefore PJ is actually locked.
  • Page 85: Cr_Shuth Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.11.41 CR_SHUTH Command Command “CR_SHUTH” [CR] Details Get time setting to start the shutter management Acceptable “000_%1” [CR] “005” -------------------- 5 minutes “006” -------------------- 6 minutes Response “479” -------------------- 479 minutes “480” -------------------- 480 minutes Unacceptable “Error Code”...
  • Page 86: Cr_Testpat Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.11.45 CR_TESTPAT Command Command “CR_TESTPAT” [CR] Details Get setting status of Test pattern Acceptable “000_%1” [CR] “COLOR” ---------------------- Color bar is displayed “GRAD1” ---------------------- 16step(white→black) is displayed “GRAD2” ---------------------- 16step(white←black) is displayed “GRAD3” ---------------------- 16step(white↓black) is displayed Response “GRAD4”...
  • Page 87: Other Status Read Commands

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.12 Other Status Read Commands 9.12.1 CR_STATUS Command COMMAND “CR_STATUS” [CR] Get operating status of Projector Detail Same as “CR0” in basic command except error code follows it. Acceptable “000_%1” [CR] “00” = Power ON “80”...
  • Page 88: Cr_Tempfail Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.12.5 CR_TEMPFAIL Command Command “CR_TEMPFAIL” [CR] Get the temperature inside a projector when abnormal temperature status Details occurs. It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2_%3” [CR] %1 ------------------ Sensor 1 temp.
  • Page 89: Cr_Temp Command

    PLC-ZM5000/ZM5000L Expand Serial Command Functional Specifications 9.12.6 CR_TEMP Command Command “CR_TEMP” [CR] Get the current temperature information inside a projector. Details It is possible to get the temperatures all at once when several sensors installed. Acceptable “000_%1_%2_%3” [CR] %1 ------------------ Sensor 1 temp. (External temp.) %2 ------------------ Sensor 2 temp.

This manual is also suitable for:

Plc-zm5000Plc-zm5000l

Table of Contents