Page 1
CONFIDENTIAL BX B7S / BLED Heat Pump Tumble Dryer Step 11: “Start/Pause” button is pressed. “Anti-Creasing Led” lights on. Motor start to rotate in counter-clockwise direction. “Sound Warning Led” starts to blink and it is allowed to pass to the next step.
Page 2
CONFIDENTIAL Beko2013 Good+ Heat Pump Tumble Dryer Step 3: “Start/Pause” button is pressed. Version of main software is shown on display and service test program waits another “Start/Pause”press. Step 4: “Start/Pause” button is pressed. Revision of main software is shown on display and service test program waits another “Start/Pause”press.
Page 3
CONFIDENTIAL BX B7S / BLED Heat Pump Tumble Dryer Step 8: “Start/Pause” button is pressed. The door and compressor NTC are checked in this step. If there is no short or open circuit sensation error, door NTC value and compressor NTC value are sequentially shown on display and it is allowed to pass to next step.
Page 4
CONFIDENTIAL Beko2013 Good+ Heat Pump Tumble Dryer Step 12: “Start/Pause” button is pressed. Motor continues to rotate in clockwise direction. “Clean Filter Led” starts to blink for humidity sensor short circuit control. Open the door of tumble dryer and make the sensor short circuit by touching the sensor plate.
Page 5
CONFIDENTIAL BX B7S / BLED Heat Pump Tumble Dryer Step 15: “Start/Pause” button is pressed. “Crn” appears on display. Compressor starts to work. After that, compressor NTC value appears on display and the value starts to increase. If the compressor NTC value reaches the 50-55 °C, “C on”...
Page 6
CONFIDENTIAL Beko2013 Good+ Heat Pump Tumble Dryer Error Codes: Error Codes Definition E 00 : No error E 01 : Door Opened While Running E 02 : Tank Full E 03 : Drum Empty E 04 : Start While Door Open E 05 : Maximum Time E 06 : Door NTC: Open Circuit E 07 : Door NTC: Short Circuit...