User Manual | Gas Detection Honeywell BW™ Ultra Portable Five-gas Detector with Internal Pump...
Page 2
Honeywell until receipt by the buyer of shipping instructions from Honeywell. • The right of Honeywell to require that the buyer provides proof of purchase such as the original invoice, bill of sale, or packing slip to establish that the product is within the warranty period.
Sensor T90 Ratings.........................17 Activate the backlight ........................ 7 Label Information........................18 Deactivate the detector ......................7 BW Ultra Battery label ....................18 BW Ultra Instrument label ..................20 Navigate the menu ........................7 Part Number Format .......................22 View detector’s general information ................... 7 Sensor Replacement .......................23...
Oxygen (O2) % volume In no event is Honeywell liable to anyone for any indirect, special, Combustible gases (LEL) a) percent of lower explosive limit (%LEL) or consequential damages. The information and specifications Lower explosive limit b) percent by volume methane 0-5.0% v/v...
• The lithium battery in this product presents a risk of fire, explosion, and chemical • DO NOT rely on the Bluetooth BW Ultra output indication for security purposes. burn if misused. Do not open, crush, disassemble, incinerate, or heat above 100°C (212°F).
Electrical Equipment for Explosive Atmospheres agréé ou un centre de traitement des matières dangereuses. Éloignez les enfants des piles au lithium. • Ne comptez PAS sur l’indication de sortie Bluetooth BW Ultra à des fins de Natural Institute of Metrology, Quality, and sécurité.
Bump test failed TWA alarm Correction factor Peak gas exposure Firmware update in Over limit alarm progress High alarm Sensor disabled This icon flashes to indicate regular Low alarm operation without any gas alarms or functional errors BW Ultra User Manual...
Depending on the type of Fast flash alarm, these flashes, vibrations, and noises will be different. NOTE: In Stealth mode the Honeywell BW™ Ultra only Black box around gas Over Limit vibrates. flashes...
Alternate Display Background To activate its functionality: 1. Go to Instrument Operation Tab. 2. Check or uncheck the Normal Display box to activate or deactivate the White Background. BW Ultra User Manual...
Configurator to reset readings in the detector. 1. Go to the main menu and select > See Information > Peak readings. 2. Select Hold to reset peak readings. Press and hold for 3 seconds to reset readings. BW Ultra User Manual...
Passed will be displayed. Press the button to exit be bypassed. calibration. If the calibration failed for some or all of the gases, either a Cal Error All gases applied mixed results message (if the detector was not successfully BW Ultra User Manual...
15 minutes between calibrations and all the nests used in gang should be for BW Ultra. If it is not the case, it 9. The detector will prompt you Did you see and hear...
The detector can be used in one of three modes: Essentials mode, Hole Watch mode, and Inert mode. : Honeywell BW™ Ultra always monitors gas levels, regardless of Note the operating mode. If the detector detects a sudden gas exposure, it will flash, vibrate, and produce a loud siren noise.
General Sensor Settings (for all sensors) • Sensor Enable/Disable • Calibration Gas Concentration : When the operator configures the Honeywell BW™ Ultra using Note Safety Suite Device Configurator, Honeywell strongly recommends reviewing the detector’s settings before the operation to ensure that settings were applied successfully and comply with performance requirements.
The type of sensor can only be configured at within 8 hours. factory during assembly process. Due to above, the user request a BW Ultra with a dummy sensor in the Analog sensor position, then this dummy Maintain the Battery position will not be able to configure and install an analog sensor.
Languages button to see the connected devices. 3. Click over the device serial number. Honeywell BW™ Ultra supports six languages: English, 4. Click the Update button on the Device Details screen French, German, Portuguese, Spanish, Simplified Chinese. below the Firmware Version section.
II 1 G Ex da ia IIC T4 Ga, -40°C ≤ Tamb ≤ +50°C (with LEL sensor installed and without IR sensor installed) The Honeywell BW™ Ultra gas detector is in conformity with the following standards and certifications: I M1 Ex db ia I Ma, -20°C ≤ Tamb ≤ +50°C II 2 G Ex db ia IIC T4 Gb, -20°C ≤...
Page 19
IP54. Other IP ratings are not the scope of ISA 60079- This device complies with FCC radiation exposure limits 29-1. Honeywell BW™ Ultra was pressure tested for 80, 100 set forth for an uncontrolled environment and meets the and 120 kPa in ISA 60079-29-1. Outside of 80 - 120 kPa is FCC radio frequency (RF) Exposure Guidelines.
Sensor T90 Ratings Please be advised of the following T90 ratings for the BW Ultra sensors stated below: Sensor Type T90 Ratings LEL Sensor (1LEL75C) for Methane is < 20 sec @ 20°C Oxygen (O2) Sensor: 1O2 for O2 is typically <15 sec Carbon Monoxide (CO) Sensor: CO 4R+ for CO is <...
4. Class Zone protection markingwhen BW Ultra is configured with LEL and without IR sensor 5. Class Zone protection marking when BW Ultra is configured with IR sensor and without LEL sensor 6. Class Zone protection marking when BW Ultra is configured with IR sensor and with LEL sensor 7.
Page 24
XXXX XXXX UL21UKEX2006X UL21UKEX2006X UL21UKEX2006X 5. ATEX certificate number 6. BW Ultra part number and 2D barcode 7. BW Ultra serial number and 2D barcode IECEx Ex ia I Ma, Ex ia I Ma, Ex ia I Ma, Ex ia IIC T4 Ga...
Part Number Format BW Ultra’s explosion-proof protection type varies per the sensor configuration. The user can notice the sensor configuration with the part number format. B. (5 mm X 5 mm) 2D barcode for Part Number: 14 digits 1 digit for country code...
4HYT, manufactured by City 50122982-089 032-0121-000, manufactured by RAE Systems 50122982-090 032-0112-000, manufactured by RAE Systems 50122982-091 4HN, manufactured by City 50122982-092 032-0111-000, manufactured by City 50122982-210 CO-AX, manufactured by Alphasense 50122982-203 Empty sensor, manufactured by RAE Systems BW Ultra User Manual...
Detector automatically deactivates. Automatic deactivation due to critical low Replace the battery. battery. Lockout on Self-Test Error is enabled and Change the sensor. a sensor(s) has failed the startup self-test. Sensor(s) require calibration. Calibrate the detector. BW Ultra User Manual...
Safety Suite Device Configurator accumulated averages of gases. Using the US Occupational Safety and A proprietary, Windows-based software developed by Honeywell to Health Administration (OSHA) method or the American Conference of configure and manage docking modules, calibration, bump tests, and data Governmental Hygienists (ACGIH) method, an average is calculated to logs.