Owner’s Manual Permanently Lubricated Single Stage Portable AIR COMPRESSOR Model No. 919.724700 • Safety Guidelines • Assembly • Operation • Maintenance • Service and Adjustments • Troubleshooting • Repair Parts CAUTION: Read the Safety Guidelines and All Instructions Carefully Before Operating.
If this air compressor is used for commercial or rental purposes, the warranty will apply for ninety days (90) from the date of purchase. This Craftsman Air Compressor warranty gives you specific legal rights and you may have other rights which vary from province to province.
SPECIFICATION CHART Model No. Max. Developed HP Bore Stroke Voltage-Single Phase Minimum Branch Circuit Requirement Fuse Type Air Tank Capacity Approx. Cut-In Approx. Cut-out SCFM @ 40 psig SCFM @ 90 psig SAFETY GUIDELINES - DEFINITIONS This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS.
RISK OF EXPLOSION OR FIRE WHAT CAN HAPPEN IT IS NORMAL FOR ELECTRICAL CONTACTS WITHIN THE MOTOR AND PRESSURE SWITCH TO SPARK. IF ELECTRICAL SPARKS FROM COMPRESSOR COME INTO CONTACT WITH FLAMMABLE VAPORS, THEY MAY IGNITE, CAUSING FIRE OR EXPLOSION. RESTRICTING ANY OF THE COMPRESSOR VENTILATION OPENINGS WILL CAUSE SERIOUS OVERHEATING AND COULD CAUSE...
RISK OF BURSTING AIR TANK: THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK, AND RESULT IN A VIOLENT TANK EXPLOSION AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY. WHAT CAN HAPPEN FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK, CAUSING RUST AND THINNING OF THE STEEL TANK.
RISK OF ELECTRICAL SHOCK WHAT CAN HAPPEN YOUR AIR COMPRESSOR IS POWERED BY ELECTRICITY. LIKE ANY OTHER ELECTRICALLY POWERED DEVICE, IF IT IS NOT USED PROPERLY IT MAY CAUSE ELECTRIC SHOCK. REPAIRS ATTEMPTED BY UNQUALIFIED PERSONNEL CAN RESULT IN SERIOUS INJURY OR DEATH BY ELECTROCUTION.
WHAT CAN HAPPEN TOUCHING EXPOSED METAL SUCH AS THE COMPRESSOR HEAD OR OUTLET TUBES, CAN RESULT IN SERIOUS BURNS. RISK FROM MOVING PARTS WHAT CAN HAPPEN MOVING PARTS SUCH AS THE PULLEY, FLYWHEEL AND BELT CAN CAUSE SERIOUS INJURY IF THEY COME INTO CONTACT WITH YOU OR YOUR CLOTHING.
Page 8
REVIEW AND UNDERSTAND ALL INSTRUCTIONS AND WARNINGS IN THIS MANUAL. BECOME FAMILIAR WITH THE OPERATION AND CONTROLS OF THE AIR COMPRESSOR. KEEP OPERATING AREA CLEAR OF ALL PERSONS, PETS, AND OBSTACLES. KEEP CHILDREN AWAY FROM THE AIR COMPRESSOR AT ALL TIMES.
Become familiar with these terms before operating the unit. CFM: Cubic feet per minute. SCFM: Standard cubic feet per minute; a unit of measure of air delivery. PSIG: Pounds per square inch gauge; a unit of measure of pressure. Code Certification: Products that bear one or more of the following marks: UL, CUL, ETL, CETL, have been evaluated by OSHA certified...
Air compressors should be operated on not more than a 50% duty cycle. This means an air compressor that pumps air more than 50% of one hour is considered misuse, because Contents of Carton 1 - Air Compressor 1 - Handle...
HOW TO SET UP YOUR UNIT Location of the Air Compressor Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air.
Page 12
Extension Cords Use extra air hose instead of an extension cord to avoid voltage drop and power loss to the motor, and to prevent overheating. If an extension cord must be used, be sure it is: • a 3-wire extension cord that has a 3-blade grounding plug, and a 3-slot receptacle that will accept the plug on the product...
“cut-out” pressure. Safety Valve: If the pressure switch does not shut off the air compressor at its “cut-out” pressure setting, the safety valve will protect against high pressure by “popping out” at its factory set pressure (slightly higher than the pressure switch “cut-out”...
This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced. Make sure the On/Auto/Off lever is in the "OFF"...
Plug the power cord into the correct branch circuit receptacle. (Refer to Voltage and Circuit Protection paragraph in the Installation section of this manual.) Open the drain valve fully (counter- clockwise) to permit air to escape and prevent air pressure build up in the air tank during the break-in period.
To ensure efficient operation and longer life of the air compressor outfit, a routine maintenance schedule should be prepared and followed. The following routine maintenance schedule is geared to...
Page 17
After the water has been drained, close the drain valve (clockwise). The air compressor can now be stored. NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, the reinstalled.
ALL MAINTENANCE AND REPAIR OPERATIONS NOT LISTED MUST BE PERFORMED BY TRAINED SERVICE TECHNICIAN. Before servicing: • Unplug or disconnect electrica supply to the air compressor. • Bleed tank of pressure. • Allow the air compressor to cool. To Replace or Clean Check...
Page 19
12. Replace the outlet tube and tighten nuts. 13. Replace shrouds and console. 14. Perform the Break-in Procedure. See "Break-in Procedure" in the Operation section. To Replace Regulator Release all air pressure from air tank. See "To Drain Tank" in the Maintenance section.
Protect the electrical cord and air hose from damage (such as being stepped on or run over). Wind them loosely around the compressor handle. Store the air compressor in a clean and dry location. 20- ENG Water will condense in the air...
Performing repairs may expose voltage sources, moving parts or compressed air sources, moving parts or compressed air sources. Personal injury may occur. Prior to attempting any repairs, unplug the air compressor and bleed off all air tank air pressure. PROBLEM...
Page 22
PROBLEM Pressure reading It is normal for "some" on the regulated pressure drop to occur. pressure gauge drops when an accessory is used. Possible defect in safety Knocking Noise. valve. Defective check valve. Prolonged excessive use of Compressor is air. not supplying enough air to Compressor is not large...
Page 23
PROBLEM Regulator will Damaged regulator not shut off air outlet. Motor will not Motor overload protection run. switch has tripped Tank pressure exceeds pressure switch “cut-in” pressure. Extension cord is wrong length or gauge. Check valve stuck open. Loose electrical connections. Check wiring connection Possible defective motor or starting capacitor.
Page 24
à compter de la date d’achat, sur un compresseur qui est utilisé à des fins commerciales ou comme appareil de location Cette garantie sur le compresseur d'air de Craftsman vous donne des droits particuliers. Il se peut que vous ayez d’autres droits qui varient d’une province à l’autre.
TABLEAU DES SPÉCIFICATIONS Modèle no : CV maximum développés Alésage Course du cylindre Tension – phase unique Exigence minimale du circuit de dérivation Genre de fusible Capacité du réservoir d’air Pression d’enclenchement approx. Pression de coupe-circuit approx. Pi3/min standard (SCFM) à 40 psi (lb/po. ca.) Pi3/min standard (SCFM) à...
Page 26
RISQUE D’EXPLOSION OU D’INCENDIE RISQUE LES ÉTINCELLES QUI PROVIENNENT DES CONTACTS ÉLECTRIQUES DU MOTEUR ET DU MANOSTAT SONT CONSIDÉRÉES NORMALES. SI DES ÉTINCELLES ÉLECTRIQUES DU COMPRESSEUR ENTRENT EN CONTACT AVEC DES VAPEURS INFLAMMABLES, ELLES PEUVENT S’ENFLAMMER, PROVOQUANT UN INCENDIE OU UNE EXPLOSION.
Page 27
RISQUE D’ÉCLATEMENT RÉSERVOIR D’AIR : LES CONDITIONS SUIVANTES PEUVENT AFFAIBLIR LES PAROIS DU RÉSERVOIR ET PROVOQUER UNE EXPLOSION VIOLENTE DU RÉSERVOIR QUI RISQUE DE CAUSER DES DOMMAGES À LA PROPRIÉTÉ OU DES BLESSURES GRAVES. RISQUE LE DÉFAUT DE VIDANGER DE FAÇON APPROPRIÉE L’EAU CONDENSÉE DANS LE RÉSERVOIR RISQUE DE CAUSER LA ROUILLE ET...
Page 28
RISQUE DE CHOC ÉLECTRIQUE RISQUE VOTRE COMPRESSEUR D’AIR EST ALIMENTÉ PAR ÉLECTRICITÉ. COMME AVEC TOUS LES APPAREILS ÉLECTRIQUES, SI L’APPAREIL N’EST PAS UTILISÉ DE FAÇON APPROPRIÉE, IL PEUT CAUSER DES CHOCS ÉLECTRIQUES. TOUTE RÉPARATION EFFECTUÉE PAR UNE PERSONNE NON QUALIFIÉE PEUT ENTRAÎNER DES BLESSURES GRAVES OU LA MORT PAR ÉLECTROCUTION.
Page 29
RISQUE DE BRÛLURES RISQUE LE FAIT DE TOUCHER AUX SURFACES DE MÉTAL EXPOSÉES TELLES QUE LA TÊTE DU COMPRESSEUR OU LES TUBES DE SORTIE PEUT CAUSER DE GRAVES BRÛLURES À LA PEAU. RISQUE RELIÉ AUX PIÈCES MOBILES RISQUE LES PIÈCES MOBILES TELLES QUE LA POULIE, LE VOLANT-MOTEUR ET LA COURROIE PEUVENT ENTRAÎNER DES BLESSURES GRAVES SI ELLES ENTRENT EN...
Page 30
RISQUE DE DOMMAGES À LA PROPRIÉTÉ PENDANT LE TRANSPORT DU COMPRESSEUR (incendie, inhalation, dommages aux surfaces du véhicule) RISQUE DES FUITES OU DES DÉVERSEMENTS D’HUILE PEUVENT SE PRODUIRE ET ENTRAÎNER DES RISQUES D’INCENDIE, OU DES PROBLÈMES AUX VOIES RESPIRATOIRES, DES BLESSURES GRAVES OU LA MORT. DES FUITES D’HUILE ENDOMMAGENT LES TAPIS, LA PEINTURE ET TOUTE AUTRE SURFACE DES VÉHICULES OU DES REMORQUES.
Veuillez vous familiariser avec ces termes avant d'utiliser l'appareil. CFM : pieds cubes par minute (pi SCFM : pieds cubes par minute (pi standard. Une unité de mesure de débit d'air. PSIG: jauge indiquant le nombre de livres par pouce carré (lb/po ).
Les compresseurs d'air ne devraient pas avoir un cycle de service supérieur à 50%. Cela veut dire qu'un compresseur qui a pompé de l'air pendant plus de 50% d'une heure est considéré comme avoir subi un mauvais usage parce que Contenu de l'emballage en carton 1 - Compresseur d'air 1 - Poignée...
MONTAGE DE L'APPAREIL Emplacement du compresseur d'air Le compresseur d'air doit être situé dans un endroit propre, sec et bien aéré. Le compresseur d'air doit être situé à une distance d'au moins 12 po (30 cm) du mur ou de toute autre obstruction qui pourrait nuire au débit d'air.
Page 34
Rallonges Utilisez un boyau d'air supplémentaire au lieu d'une rallonge pour éviter une chute de tension, une perte de puissance et la surchauffe du moteur. Si une rallonge doit être utilisée, s'assurer : • d'utiliser une rallonge à trois fils, munie d'une fiche à...
Familiarisez-vous avec votre compresseur d'air LISEZ CE GUIDE DE L'UTILISATEUR ET TOUTES LES MESURES DE SÉCURITÉ AVANT D'UTILISER CET APPAREIL. Comparez les illustrations à votre appareil pour vous familiariser avec l'emplacement des commandes et boutons de réglage. Conservez ce guide pour références ultérieures. Manostat Manomètre de Description du fonctionnement...
Page 36
Système de refroidissement (non illustré) : Ce compresseur d'air offre un système de refroidissement de pointe. Le cœur de ce système de refroidissement et un ventilateur. Il est tout à fait normal que ce ventilateur souffle une grande quantité d'air à travers les trous d'aération. L'expulsion d'air indique que le système de refroidissement est en fonction.
Page 37
Branchez le cordon d'alimentation dans la prise de courant du circuit de dérivation approprié. (Consultez le paragraphe sur la protection contre la surtension et la protection du circuit de la section sur l'installation de ce guide.) Ouvrez complètement le robinet de vidange tournant dans le...
Responsabilités du client Vérifier la soupape de sûreté Vidanger le réservoir Filtre à air Inspecter les conduites d'air et les raccords pour des fuites Soupapes d'admission et d'échappementde la pompe du compresseur d'air 1 - plus fréquemment dans des conditions poussiéreuses ou humides L'appareil fonctionne automatiquement en cycles lorsqu'il est...
Page 39
peut condenser. Si l'eau n'est pas vidangée, cela risque de corroder et d'affaiblir le réservoir d'air, produisant ainsi un risque de rupture du réservoir d'air. Une fois la vidange de l'eau terminée, fermez le robinet de vidange (tournez dans le sens des aiguilles d'une montre).
ENTRETIEN ET RÉGLAGES d'air fonctionne automatiquement lorsqu'il est sous tension. En effectuant l'entretien, vous pourriez être exposé aux sources de tension, à de l'air comprimé ou aux pièces en mouvement et subir ainsi des blessures corporelles. Avant de procéder à tout entretien ou réparation, débranchez le compresseur et purgez tout l'air pressurisé.
Page 41
10. Appliquez un produit d'étanchéité sur les filets de la soupape de retenue. Réinstaller la soupape (en tournant dans le sens des aiguilles d'une montre). 11. Remettez en place le tube de décharge de pression et serrez les écrous. 12. Remettez en place le tube de sortie et serrez les écrous.
Avant de ranger le compresseur d'air, effectuez les étapes suivantes : Revoyez la section intitulée "Entretien" des pages précédentes et exécutez l'entretien requis. Placez le levier "On/Auto/Off" à la position "OFF". Tournez le régulateur dans le sens contraire des aiguilles d'une montre et réglez la pression de sortie à...
Page 43
pièces mobiles ou aux sources d'air comprimé qui risquent de causer des blessures corporelles. Débranchez le compresseur et purgez l'air pressurisé du réservoir avant d'entamer toute réparation. PROBLÈME Le manostat n’arrête pas le moteur Pression excessive - lorsque le compresseur d'air atteint la soupape de sûreté...
Page 44
PROBLÈME Le relevé de pression Une légère chute de pression est sur le manomètre du considérée normale. régulateur tombe lorsqu'un accessoire est utilisé. Soupape de retenue défectueuse. Cognements. Défectuosité possible dans la soupape de sûreté. Utilisation prolongée et excessive de Le compresseur d'air l'air.
Page 45
PROBLÈME Le régulateur ne Régulateur endommagé ferme pas l'orifice de sortie d'air. Le moteur ne tourne Interrupteur de protection contre les surcharges déclenché. pas. La pression dans le réservoir est supérieure à la "pression d'amorçage" du manostat. Rallonge de longueur ou de calibre inapproprié.