Product Description

Type:
Native Resolution:
Brightness:
Power Lens Shift/Power Zoom/Power Focus
Lens Specification
TL-08SF
Throw Ratio: 0.84:1
Screen Sizes: 80" - 500" (5:4)
TL-1ZH
Throw Ratio: 1.5 - 2.5:1
Screen Sizes: 80" - 500" (5:4)
TL-2Z
Throw Ratio: 2.5 - 4.0:1
Screen Sizes: 80" - 500" (5:4)
TL-4Z
Throw Ratio: 4.0 - 7.0:1
Screen Sizes: 80" - 500" (5:4)
Notes
For screen not indicated in the tables, use formulas below.
If the figures in the tables do not match the results of formulas, use the figures in the tables.
The ceiling must be strong enough to support the projector and the installation must be in accordance with any local building
codes.
Distances are in inches, for millimeters multiply by 25.4
Distances may vary ± 5%.
Formulas
Throw Distance = Screen Width (H) x Lens Magnification
Note: Image has 5:4 aspect ratio. Take this into account when specifying a screen.
Lens
Throw Distance Formula
TL-08SF:
H x 0.84
TL-1ZH:
(Wide) = H x 1.5
TL-2Z:
(Wide) = H x 2.5
TL-4Z:
(Wide) = H x 4.0
Note: Do not use TL-1Z lens on SX10000, for optimal performance TL-1ZH should be used for 1.5-2.5:1 range.
3 chip, 0.9" DLP
1280 x 1024 (5:4)
8000 ANSI Lumens
F/#:
Lateral color error: 14 µm max
F/#:
Lateral color error: 14 µm max
F/#:
Lateral color error: 14 µm max
F/#:
Lateral color error: 14 µm max
(Tele) = H x 2.5
(Tele) = H x 4.0
(Tele) = H x 7.0
Page 1
Page 2
Page 3
Page 4
Page 5
Page 6
Page 7
Page 8
Page 9
Page 10
Dimensions:
27.91"(W) x 16.85"(H) x 45.45"(D) w/handles,
w/o lens
Weight:
185.3 lbs w/o lens
3.0
3.0
3.0
3.0
H = Screen Width (5:4)
V = Screen Height (5:4)
Screen Diagonal (5:4) = Screen Height (V) x 6.4/4
Visual Systems
Distortion (full offset):
Distortion (full offset):
Distortion (full offset):
Distortion (full offset):
H = Screen Height (V) x 5/4
V = Screen Width (H) x 4/5
Ver 1.6
1% max
2% max
2% max
2% max
Page1

Advertisement

Table of Contents
loading

Summary of Contents for NEC SX10000D

  • Page 1: Table Of Contents

    If the figures in the tables do not match the results of formulas, use the figures in the tables. • The ceiling must be strong enough to support the projector and the installation must be in accordance with any local building codes.
  • Page 2: Desktop Setup

    SX10000 Installation Data Desktop and Ceiling Projection Distance and Screen Size for No Offset Installation The following shows the proper relative positions of the projector and screen. Dimensions are in inches. For millimeters multiply by 25.4. Desktop (no offset/optimum condition) Screen Ctr Note: Image has 5:4 aspect ratio.
  • Page 3: Ceiling Installation

    Projection Distance and Screen Size for Ceiling /With Offset The following shows the proper relative positions of the projector and screen. Refer to the table to determine the position of installation. Dimensions are in inches. For millimeters multiply by 25.4.
  • Page 4: Lens Shift Adjustable Range

    SX10000 Installation Data Desktop and Ceiling Lens Shift Adjustable Range Lens Shift Adjustable Range for Desktop and Ceiling Application. The diagram below shows the location of the image position in the lens. The lens can be shifted within the shaded area as shown using the normal projection position as a starting point.
  • Page 5: Tl-08Sf Lens

    (Refer to diagram) Note: To reduce the distortion of an image, it is recommended that the projector is horizontally positioned at a projection angle of 0 degrees. H: width of projected image V: height of projected image (5:4) 0.06H...
  • Page 6: Cabinet Dimensions

    SX10000 Installation Data Desktop and Ceiling Cabinet Dimensions The following drawings show the cabinet dimensions for the SX10000. Dimensions are in inches. For millimeters multiply by 25.4. 8-M10*L20 1.69 24.65 16.02 1.69 Visual Systems 2.36 0.315 14.17 Ver 1.6 Page6...
  • Page 7: Back, Top & Right Side

    SX10000 Installation Data Desktop and Ceiling Cabinet Dimensions (continued) The following drawings show the cabinet dimensions for the SX10000. Dimensions are in inches. For millimeters multiply by 25.4. 26.77 0.57 Visual Systems Ver 1.6 Page7...
  • Page 8: Lens Dimensions

    SX10000 Installation Data Desktop and Ceiling Lens Dimensions The following drawings show the lenses mounted on the projector. Dimensions are in inches. For millimeters multiply by 25.4. 6.47 TL-08SF 0.84:1 Fixed Lens 2.70 TL-1ZH 1.5-2.5:1 Zoom Lens 4.14 TL-2Z 2.5-4.0:1 Zoom Lens 4.36...
  • Page 9: Command Codes

    The unit address is not checked when the unit ID has become a general notification. Please set "0" to the unit ID and set "00" to the unit address when you use the projector under the standalone mode. Visual Systems Ver 1.6...
  • Page 10: Connection

    SX10000 Installation Data Desktop and Ceiling RS232 Control / Connection Cable Connection Communication Protocol Baud rate: Data length: Parity: Stop bit : X on/off: Communication procedure: Note: For cable lengths longer than 20’, it is recommended changing baud rate to 9600 bps. PC Control Connector (D-Sub 9P) To TxD of PC To RxD of PC...

This manual is also suitable for:

Sx10000

Table of Contents