3.15

[ 037. INFORMATION REQUEST ]

Gets the information of the projector.
Command
03h 8Ah 00h 00h 00h 8Dh
Response
When the command succeeds
23h 8Ah <ID1> <ID2> 62h <DATA01> - <DATA98> <CKS>
Data part
Item
DATA01 - 49
DATA50 - 82
DATA83 - 86
DATA87 - 90
DATA91 - 98
When the command fails
A3h 8Ah <ID1> <ID2> 02h <ERR1> <ERR2> <CKS>
Response example
When the lamp usage time is18000 seconds (5 hours)
23h
8Ah
<DATA87> - <DATA98> <CKS>
Lamp usage time (DATA83 – DATA86) = 18000 / 3600 = 5 hours
Information
While the usage time can be obtained in one-second units, the information is updated at one-minute intervals.
©NEC Display Solutions, Ltd. 2014-2020
Projector name (NUL: termination character string).
Reserved for the system
Lamp usage time (seconds)
Filter usage time (seconds)
Reserved for the system
<ID1>
<ID2>
62h
Description
<DATA01> - <DATA82>
32
50h
46h
00h
00h