hit counter script
Mitsubishi Electric FR-A8APS-02 Instruction Manual
Mitsubishi Electric FR-A8APS-02 Instruction Manual

Mitsubishi Electric FR-A8APS-02 Instruction Manual

Ssi communication function

Advertisement

Quick Links

INVERTER
Plug-in option
FR-A8APS-02
INSTRUCTION MANUAL
SSI communication function
PRE-OPERATION INSTRUCTIONS
INSTALLATION AND WIRING
SSI communication functions
INVERTER SETTING
TROUBLESHOOTING
1
2
3
4
5

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi Electric FR-A8APS-02

  • Page 1 INVERTER Plug-in option FR-A8APS-02 INSTRUCTION MANUAL SSI communication function PRE-OPERATION INSTRUCTIONS INSTALLATION AND WIRING SSI communication functions INVERTER SETTING TROUBLESHOOTING...
  • Page 2 Thank you for choosing this Mitsubishi Electric inverter plug-in option. This Instruction Manual provides handling information and precautions for use of this product. Incorrect handling might cause an unexpected fault. Before using this product, read all relevant instruction manuals carefully to ensure proper use.
  • Page 3  Additional instructions The following instructions must be also followed. If this product is handled incorrectly, it may cause unexpected fault, an injury, or an electric shock. CAUTION Transportation and installation  Do not stand or place heavy objects on this product. ...
  • Page 4: Table Of Contents

    ─ CONTENTS ─ 1 PRE-OPERATION INSTRUCTIONS Unpacking and product confirmation.......................6 1.1.1 Product confirmation............................6 Component names .............................7 2 INSTALLATION AND WIRING Pre-installation instructions ........................8 Installation procedure ..........................8 Wiring ................................11 Terminals..............................12 3 SSI communication functions Supported distance meters ........................13 Connection example ..........................14 4 INVERTER SETTING Parameter list ............................15 Parameter adjustment ..........................17...
  • Page 5 Appendix2 Instructions for EAC ............................23 Appendix3 Restricted Use of Hazardous Substances in Electronic and Electrical Products ........24 Appendix4 Referenced Standard (Requirement of Chinese standardized law) .............. 25...
  • Page 6: Pre-Operation Instructions Unpacking And Product Confirmation

    PRE-OPERATION INSTRUCTIONS Unpacking and product confirmation Take the plug-in option out of the package, check the product name, and confirm that the product is as you ordered and intact. This product is a plug-in option dedicated for the FR-A800-AWH series inverter. 1.1.1 Product confirmation Check the enclosed items.
  • Page 7: Component Names

    Component names Front view Rear view Terminal layout TST1 UP UN DT+ TST2 UP UN TST3 TST4 TST5 TST6 Do not use terminals TST1 to TST6 and UP. When using terminal UN, use the upper one. Symbol Name Description Refer to page Used to fix this product to the inverter by inserting a mounting screw Mounting hole or a spacer.
  • Page 8: Installation And Wiring Pre-Installation Instructions

    INSTALLATION AND WIRING Pre-installation instructions Check that the inverter's input power and the control circuit power are both OFF. CAUTION  Do not install or remove this product while the inverter power is ON. Otherwise, the inverter and plug-in option may be damaged. To avoid damage due to static electricity, static electricity in your body must be discharged before you touch the product.
  • Page 9 Connector 3 Mounting screw Spacer Spacer Connector 2 Connector 1 Spacer Spacer Mounting screw Mounting screw Insertion positions for screws and spacers INSTALLATION AND WIRING...
  • Page 10 NOTE • When installing/removing the plug-in option, hold the sides of the option. Do not press on the parts on the option circuit board. Stress applied to the parts by pressing, etc. may cause a failure. • Be careful not to drop mounting screws during the installation or removal of the plug-in option. •...
  • Page 11: Wiring

    Wiring (1) Strip the signal wires from the encoder as shown below. If too much of the wire is stripped, a short circuit may occur with neighboring wires. If not enough of wire is stripped, wires may become loose and fall out. Twist the stripped end of wires to prevent them from fraying.
  • Page 12: Terminals

    (2) Loosen the terminal screw and insert the cable into the terminal. Screw size Tightening torque Wire gauge Screwdriver Small flat-blade screwdriver 0.22 N⋅m to 0.25 N⋅m 0.3 mm to 0.75 mm (Tip thickness: 0.4 mm/tip width: 2.5 mm) NOTE •...
  • Page 13: Ssi Communication Functions

    SSI communication functions This product is an option made for the FR-A800-AWH series inverters. When the FR-A8APS-02 is installed to the FR-A800-AWH inverter, the SSI communication data can be obtained and sent to the inverter using the SSI device. SSI communication devices whose measurement method is laser, encoder, or reading bar codes are available.
  • Page 14: Connection Example

    (Example) When CMV58M-00002 is used Inverter Power supply FR-A8AP Encoder FR-A8NC CC-Link Connector master module CC-Link cable FR-A8APS-02 SSI_DATA+_OUT SSI_DATA-_OUT SSI_Clock+_IN device SSI_Clock-_IN Power supply VIN GRD ∗1 Connected when the SSI communication device has a common terminal. SSI communication functions...
  • Page 15: Inverter Setting Parameter List

    INVERTER SETTING Parameter list The following inverter parameters are used for this option (FR-A8APS-02). Set the parameter as required. The setting is applied after an inverter reset or next power-ON. Initial Setting Name Description value range Select connection method from among RS-485 terminals, Ethernet connector, and this option (FR-A8APS-02), according to the distance meter from which the current position data is received.
  • Page 16 Initial Setting Name Description value range Set the data rate of the communication between the SSI communication device and this option. SSI communication 0.1, 0.2, 1362 0.1: 0.1 MHz data rate setting 0.2: 0.2 MHz 1.0: 1.0 MHz SSI communication Set the data code for SSI communication.
  • Page 17: Parameter Adjustment

    Parameter adjustment The following shows the recommended setting values of the inverter parameters for each distance meter during SSI communication. The setting values in must be the same as the values shown in the table. • BPS307i BPS307i Inverter parameter setting value Item Description Setting value...
  • Page 18 • AMS304i AMS304i Inverter parameter setting value Item Description Setting value Initial value Type Laser 1361 Clock frequency 80 to 800 kHz 1362 0.2 (or 0.1) SSI code type Gray 1363 Number of SSI data bits 25 bit 1365 1366 24 bit Full resolution (25 bit - 1 error bit)
  • Page 19 • CMV58M-00002 CMV58M-00002 Inverter parameter setting value Item Description Setting value Initial value Type Encoder 1361 Any value of "1.0, Clock frequency 80 to 1000 kHz 1362 0.2, or 0.1" SSI code type Gray 1363 Number of SSI data bits 24 bit 1365 1366...
  • Page 20: Troubleshooting Troubleshooting

    TROUBLESHOOTING Troubleshooting Description Countermeasure • Check for cable connection between the SSI device and this option. Also make sure that the shield is connected. • Take EMC measures. The current position data is not updated. • Turn ON the power supply of the SSI device again. •...
  • Page 21: Distance Meter Fault (System Failure)

    Distance meter fault (system failure) This system failure is detected when a communication error occurs between the inverter and the distance meter, or when the data sent from the distance meter is unreliable. Set Pr.393 System failure detection to enable detection of distance meter faults.
  • Page 22: Appendix

    CE marking. • The authorized representative in the EU The authorized representative in the EU is shown below. Name: Mitsubishi Electric Europe B.V. Address: Mitsubishi-Electric-Platz 1, 40882 Ratingen, Germany  EMC Directive We declare that this product conforms with the EMC Directive when installed in a compatible inverter, and affix the CE marking on the packaging plate.
  • Page 23 (October), Y (November), or Z (December). • Authorized sales representative (importer) in the CU area The authorized sales representative (importer) in the CU area is shown below. Name: Mitsubishi Electric (Russia) LLC Address: 52, bld 1 Kosmodamianskaya Nab 115054, Moscow, Russia Phone: +7 (495) 721-2070...
  • Page 24 Appendix3 Restricted Use of Hazardous Substances in Electronic and Electrical Products The mark of restricted use of hazardous substances in electronic and electrical products is applied to the product as follows based on the “Management Methods for the Restriction of the Use of Hazardous Substances in Electrical and Electronic Products”...
  • Page 25 Appendix4 Referenced Standard (Requirement of Chinese standardized law) This Product is designed and manufactured accordance with following Chinese standards. EMC: GB/T 12668.3 APPENDIX...
  • Page 26 MEMO...
  • Page 27 REVISIONS *The manual number is given on the bottom left of the back cover. Revision Date *Manual Number Revision Sep. 2019 IB(NA)-0600898ENG-A First edition IB(NA)-0600898ENG-A...
  • Page 28 INVERTER HEAD OFFICE: TOKYO BUILDING 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN IB(NA)-0600898ENG-A(1909) MEE Printed in Japan Specifications subject to change without notice.

Table of Contents