Preface Introduction Installing the Device SIMATIC NET Device Management Rugged Ethernet Switches RUGGEDCOM RSG2100PF Communication Ports Technical Specifications Installation Manual Certification 07/2021 C79000-G8976-1345-11...
Page 3
Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
SIMATIC NET Glossary The SIMATIC NET Glossary describes special terms that may be used in this document. The glossary is available online via Siemens Industry Online Support (SIOS) at: https://support.industry.siemens.com/cs/ww/en/view/50305045 Accessing Documentation The latest user documentation for RUGGEDCOM RSG2100PF is available online at https://support.industry.siemens.com.
Preface Warranty Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
Call a local hotline center to submit a Support Request (SR). To locate a local hotline center, visit https://w3.siemens.com/aspa_app/?lang=en. Mobile App Install the Industry Online Support app by Siemens AG on any Android, Apple iOS or Windows mobile device and be able to: •...
Introduction The RUGGEDCOM RSG2100PF is a rugged, Power over Ethernet (PoE) enabled, fully managed, modular Ethernet switch specifically designed to operate reliably in electrically harsh and climatically demanding utility substation, railway and industrial environments. The RUGGEDCOM RSG2100PF’s superior rugged hardware design coupled with the embedded Rugged Operating System (ROS) provides improved system reliability and advanced cyber security and networking features, making it ideally suited for creating Ethernet networks for mission-critical, real-time, control...
Introduction 1.2 Description • Many fiber and connector options Rated for Reliability in Harsh Environments • Immunity to EMI and heavy electrical surges • Zero-Packet-Loss™ technology • -40 to 85 °C (-40 to 185 °F) operating temperature (no fans) • Conformal coated printed circuit boards (optional) •...
Introduction 1.3 Required Tools and Materials Port Status Indicator LEDs Port status indicator LEDs indicate the operational status of each port, dependent on the currently selected mode. Mode Color/State Description Status Green (Solid) Link detected Green (Blinking) Link activity No link detected Duplex Green Full duplex mode...
Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
Introduction 1.5.3 Supported Fiber Optic Cables reliable, error-free data communication, new and pre-existing communication paths should be verified for TIA/EIA-568-A compliance. The following table summarizes the relevant cabling standards: Cabling 1000Base- Required Action Category TX Compliant < 5 New wiring infrastructure required. Verify TIA/EIA-568-A compliance.
Page 15
NOTICE Worn, damaged or missing seals must be replaced immediately. Replacement seals are available for purchase from Siemens. For more information, contact a Siemens Sales representative. There are three ways to determine if a security seal has been tampered with: •...
This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens AG could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
Visually inspect each item in the package for any physical damage. Verify all items are included. Note If any item is missing or damaged, contact Siemens for assistance. Mounting the Device The RUGGEDCOM RSG2100PF is designed for maximum mounting and display flexibility.
Installing the Device 2.3.1 Mounting the Device to a Rack Note For detailed dimensions of the device with either rack, DIN rail or panel hardware installed, refer to "Dimension Drawings (Page 32)". 2.3.1 Mounting the Device to a Rack The RUGGEDCOM RSG2100PF can be secured to a standard 48 cm (19 in) rack using separately purchased rack mount adapters.
Installing the Device 2.3.2 Mounting the Device on a DIN Rail To secure the device to a standard 48 cm (19 in) rack, do the following: Note The device can be ordered with the communication ports located at the front or rear of the device.
Installing the Device 2.3.3 Mounting the Device to a Panel To mount the device to a DIN rail, do the following: Align the adapters with the DIN rails and slide the device into place. Panel/DIN Rail Adapter DIN Rail Screw Figure 2.2 DIN Rail Mounting Install one of the supplied screws on either side of the device to secure the adapters to the DIN rails.
Installing the Device 2.4 Connecting the Failsafe Alarm Relay To mount the device to a panel, do the following: Place the device against the panel and align the adapters with the mounting holes. Screw Panel/DIN Rail Adapter Figure 2.3 Panel Mounting Install the supplied screws to secure the adapters to the panel. Connecting the Failsafe Alarm Relay The failsafe relay can be configured to latch based on alarm conditions.
Installing the Device 2.5 Connecting Power Normally Open Common Normally Closed Figure 2.4 Failsafe Alarm Relay Wiring Connecting Power The RUGGEDCOM RSG2100PF supports a single AC or DC power supply, and a separate 48 VDC power supply for PoE ports. The RUGGEDCOM RSG2100PF can be equipped with either a screw-type or pluggable terminal block, which provides power to the AC/DC power supply and PoE ports.
Installing the Device 2.5.1 Connecting AC or DC Power • Equipment must be installed according to applicable local wiring codes and standards. 2.5.1 Connecting AC or DC Power To connect a single high AC, high DC or low DC power supply to the device, do the following: NOTICE Electrical hazard –...
Page 24
Installing the Device 2.5.1 Connecting AC or DC Power Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block. Screw-Type Terminal Block Pluggable Terminal Block Jumper Positive/Live (+/L) Terminal Negative/Neutral (-/N) Terminal (-/N) Surge Ground Terminal Chassis Ground Terminal Chassis Ground Connection Figure 2.5...
For IEC 61850 compliance, use an IEC 61850 compliant PoE power supply with power cabling no longer than 3 m (118 in). Otherwise, Siemens recommends using the RUGGEDCOM RPS1300 switch-mode AC power supply. For more information about this power supply, refer to https:// support.industry.siemens.com/cs/ww/en/view/109478699.
Page 26
Installing the Device 2.5.2 Connecting External PoE Power Only connect the external PoE power supply to the terminals 5 and 7. Remove the terminal block cover. If a screw-type terminal block is installed, remove the screws from terminals 5 and 7. Use these screws along with #6 ring lugs to secure the wires to the terminal block.
Installing the Device 2.5.3 Wiring Examples 2.5.3 Wiring Examples The following illustrate how to connect power to single and dual power supplies. Figure 2.8 DC and 48 VDC PoE Power Supply Figure 2.9 AC and 48 VDC PoE Power Supply RUGGEDCOM RSG2100PF Installation Manual, 07/2021, C79000-G8976-1345-11...
Device Management This section describes how to connect to and manage the device. Connecting to the Device The following describes the various methods for accessing the RUGGEDCOM RSG2100PF console and Web interfaces on the device. For more detailed instructions, refer to the RUGGEDCOM ROS Configuration Manual for the RUGGEDCOM RSG2100PF.
Device Management 3.2 Configuring the Device Name Description Comment RJ45 Male DB9 Female Ring Indicator The DSR, DCD and DTR pins are connected together internally. The CTS and RTS pins are connected together internally. RI is not connected. Communication Ports Connect any of the available Ethernet ports on the device to a management switch and access the RUGGEDCOM RSG2100PF console and Web interfaces via the device's IP address.
Communication Ports The RUGGEDCOM RSG2100PF can be equipped with various types of communication ports to enhance its abilities and performance. Module Assignment Figure 4.1 Module Assignment Each type of module has a specific location in the RUGGEDCOM RSG2100PF chassis: • Slot 5 supports a pair of Gigabit Ethernet (1 Gbps) ports •...
Communication Ports 4.1 Copper Ethernet Ports Port LED Figure 4.2 Port LEDs LED State Description Yellow (Solid) Link established Yellow (Blinking) Link activity No link detected Copper Ethernet Ports The RUGGEDCOM RSG2100PF supports several 10/100/1000Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with either RJ45 or Micro-D male connectors.
Page 32
Communication Ports 4.1 Copper Ethernet Ports Name Description 10/100Base-TX 1000Base-TX BI_DA+ Receive Data+ or Bi- Directional Pair A+ BI_DA- Receive Data- or Bi- Directional Pair A- BI_DB+ Transmit Data+ or Bi- Directional Pair B+ Reserved (Do Not Connect) BI_DC+ Transmit Data+ or Bi- Directional Pair C+ Reserved (Do Not Connect) BI_DC-...
Communication Ports 4.2 PoE Ports PoE Ports The RUGGEDCOM RSG2100PF features two standard 10/100Base-TX Power over Ethernet (POE) ports in slot 9, as well as an additional two ports in slot 10. PoE ports comply with the IEEE 802.3af standard and feature auto-sensing and automatic power off when cables are removed.
SFP Transceivers The RUGGEDCOM RSG2100PF supports up to two Small Form-Factor Pluggable (SFP) transceiver sockets, which are compatible with a wide array of SFP transceivers available from Siemens. LEDs Each socket features an LED that indicates its link state. State...
RUGGEDCOM SFP Transceiver Catalog [https:// support.industry.siemens.com/cs/ca/en/view/109482309]. IMPORTANT Only use SFP transceivers approved by Siemens for RUGGEDCOM products. Siemens accepts no liability as a result of performance issues related in whole or in part to third-party components. GBIC Optic Ethernet Ports GBIC (Gigabit Interface Converter) optic Ethernet ports are available with SC (Standard or Subscriber Connector) connectors.
Page 36
Communication Ports 4.5.1 Installing a GBIC Optical Port Make sure all electrostatic energy is dissipated before installing or removing components from the device. An electrostatic discharge (ESD) can cause serious damage to the component once it is outside the chassis. NOTICE Only install GBIC optical ports that are compatible with the RUGGEDCOM RSG2100PF.
Communication Ports 4.5.2 Removing a GBIC Optical Port Remove the dust cover from the port and store for future use. Remove the dust cap from the cable and immediately connect it to the port. Connect the cable to a network and observe the LED associated with the port. For more information about the LED, refer to "Communication Ports (Page 21)".
Technical Specifications This section details the specifications and operating conditions of the device. Power Supply Specifications The RUGGEDCOM RSG2100PF can be equipped with the following power supplies: NOTICE Electrical hazard – risk of power supply failure or damage to the device Make sure power input to the device is within the specified input range.
Note • Maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens sales associate when determining maximum segment distances. • All optical power numbers are listed as dBm averages.
14.2 Typical. Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Fast Ethernet (10/100 Mbps) Optical Specifications Mode...
Typical. Typical distance. The maximum distance is greatly dependent on factors such as cable type, the number of connectors and number of splices. Consult a Siemens sales associates when determining maximum distances. Operating Environment The RUGGEDCOM RSG2100PF is rated to operate under the following environmental conditions.
Page 42
Technical Specifications 5.9 Dimension Drawings Note Dimensional tolerances are in accordance with ISO 2768-mK, unless otherwise stated. 438.15 Figure 5.1 Overall Dimensions RUGGEDCOM RSG2100PF Installation Manual, 07/2021, C79000-G8976-1345-11...
UL 62368-1 Information Technology Equipment – Safety Part 1: General Requirements 6.1.2 European Union (EU) This device is declared by Siemens AG to comply with essential requirements and other relevant provisions of the following EU directives: • EN 62368-1 Information Technology Equipment – Safety – Part 1: General Requirements •...
Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens AG. For contact information, refer to "Contacting Siemens (Page vii)".
Quality management systems – Requirements 6.1.7 RoHS This device is declared by Siemens AG to meet the requirements of the following RoHS (Restriction of Hazardous Substances) directives for the restricted use of certain hazardous substances in electrical and electronic equipment: •...
Page 49
Certification 6.2 EMC and Environmental Type Tests EMC Type Tests per IEC 61850-3 Note • If the unit contains copper ports, the IEC 1613 conformance is Class 1, during which disturbance errors may occur but recovery is automatic. • If the unit contains all fiber ports, the IEC 1613 conformance is Class 2, during which no disturbance errors will occur.
Page 50
Certification 6.2 EMC and Environmental Type Tests Test Description Test Levels Severity Levels IEC 61000-4-18 Damped Slow Damped 2.5 kV Common Oscillatory Wave Mode on Power and Signal 1.0 kV Differential Mode on Power IEC 61000-4-29 Voltage Dips DC Power Ports 30% for 0.1 s ...
Page 51
Certification 6.2 EMC and Environmental Type Tests Description Test Levels AC Power Ports 5 kV Dielectric Signal Ports 2 kV Strength DC Power Ports 2 kV AC Power Ports 2 kV Damped Enclosure Ports 100 A/m Oscillatory Magnetic Field Environmental Type Tests Test Description Test Levels...
Page 52
Further Information Siemens RUGGEDCOM https://www.siemens.com/ruggedcom Industry Online Support (service and support) https://support.industry.siemens.com Industry Mall https://mall.industry.siemens.com Siemens AG Digital Industry Process Automation Postfach 48 48 90026 NÜRNBERG GERMANY...